Background: Use of 3-dimensional (3D) computed tomography (CT) preoperative planning and patient-specific instrumentation has been demonstrated to improve the accuracy of glenoid implant placement in total shoulder arthroplasty (TSA). The purpose of this study was to compare the accuracy of glenoid implant placement in primary TSA among different types of instrumentation used with the 3D CT preoperative planning. Methods: One hundred and seventy-three patients with end-stage glenohumeral arthritis were enrolled in 3 prospective studies evaluating patient-specific instrumentation and 3D preoperative planning. All patients underwent preoperative 3D CT planning to determine optimal glenoid component and guide pin position based on surgeon preference. Patients were placed into 1 of 5 instrument groups used for intraoperative guide pin placement: (1) standard instrumentation, (2) standard instrumentation combined with use of a 3D glenoid bone model containing the guide pin, (3) use of the 3D glenoid bone model combined with single-use patient-specific instrumentation, (4) use of the 3D glenoid bone model combined with reusable patient-specific instrumentation, and (5) use of reusable patient-specific instrumentation with an adjustable, reusable base. Postoperatively, all patients underwent 3D CT to compare actual versus planned glenoid component position. Deviation from the plan (in terms of orientation and location) was compared across groups on the basis of absolute differences and outlier analysis. Univariable and multivariable comparisons were performed. As the initial analyses showed no significant differences in preoperative factors or in deviation from the plan between Groups 1 and 2 or between Groups 4 and 5 across studies, the final analysis was across 3 major treatment groups: standard instrumentation (Groups 1 and 2), single-use patient-specific instrumentation (Group 3), and reusable patient-specific instrumentation (Groups 4 and 5). Results: In nearly all comparisons, there were no significant differences in the deviation from the plan (absolute differences or outlier frequency) for glenoid implant orientation or location across the 3 major treatment groups. Conclusions: This study did not demonstrate that any type of patient-specific instrumentation resulted in consistent differences in accuracy of glenoid implant placement in primary TSA with 3D CT preoperative planning. Surgeons have multiple patient-specific instrumentation options available for improving accuracy of glenoid implant placement when compared with 2D imaging without patient-specific instrumentation. Level of Evidence: Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.
21 November 2018 in Journal of Bone and Joint Surgery
Background: The primary objectives of this study were to evaluate the ability of a posteriorly stepped augmented glenoid component, used in patients with primary glenohumeral osteoarthritis with B2 or B3 glenoid morphology, to correct preoperative retroversion and humeral head subluxation and to identify factors associated with radiographic radiolucency and patient-reported clinical outcomes.Methods: We identified 71 shoulders with B2 or B3 glenoid morphology that underwent anatomic total shoulder arthroplasty with use of a posteriorly stepped augmented glenoid component and with a preoperative 3-dimensional computed tomography (3D-CT) scan and a minimum of 2 years of clinical and radiographic follow-up. The Penn Shoulder Score (PSS), shoulder range of motion, glenoid center-peg osteolysis, and postoperative version and humeral head subluxation were the main outcome variables of interest.Results: Follow-up was a median of 2.4 years (range, 1.9 to 5.7 years); the mean patient age at treatment was 65 ± 7 years (range, 51 to 80 years). PSS, range of motion, humeral head centering, and glenoid version were significantly improved among all patients (p < 0.0001). Patients with persistent posterior subluxation of the humeral head postoperatively had worse preoperative fatty infiltration of the teres minor and greater postoperative component retroversion (p < 0.05). Patients with center-peg osteolysis had more preoperative joint-line medialization and posterior glenoid bone loss (p < 0.05). Patients with more preoperative humeral head posterior subluxation had a lower PSS, adjusting for confounders (p < 0.05).Conclusions: Posteriorly stepped augmented glenoid components can improve pathologic retroversion and posterior subluxation of the humeral head in B2 and B3 glenoids, with significant improvements found in clinical outcome scores at a minimum of 2 years of follow-up in the vast majority of patients.Level of Evidence: TherapeuticLevel IV. See Instructions for Authors for a complete description of levels of evidence.
Background: Posterior glenoid bone loss is commonly associated with primary glenohumeral osteoarthritis. Surgical management of bone loss in anatomic total shoulder arthroplasty (aTSA) remains controversial. We studied the use of a stepped augmented glenoid component for management of Walch B2 and B3 glenoids and compared the radiographic and clinical outcomes at short-term follow-up with those achieved with a non-augmented component of the same design in Walch A1 glenoids. Methods: Ninety-two patients (42 A1, 29 B2, and 21 B3 glenoids) were prospectively followed after aTSA. Sequential 3-dimensional (3D) computed tomography (CT) imaging was performed preoperatively, within 3 months postoperatively with metal artifact reduction (MAR) to define implant position, and at a minimum of 2 years postoperatively with MAR. Scapular 3D registration with implant registration allowed 3D measurement of glenoid implant position, implant shift, and central peg osteolysis (CPO). Results: CPO with or without implant shift occurred in a higher percentage of B3 glenoids treated with the augmented glenoid component (29%) than A1 glenoids treated with a standard component (5%) (p = 0.028). There was no significant difference in the frequency of CPO between B2 glenoids with the augmented component (10%) and A1 glenoids with the standard component. There was no difference in postoperative glenoid component version and inclination between groups. B3 glenoids were associated with more component medialization relative to the premorbid joint line compared with A1 and B2 glenoids (p < 0.001). Conclusions: A stepped augmented glenoid component can restore premorbid glenoid anatomy in patients with asymmetric biconcave glenoid bone loss (Walch B2), with short-term clinical and radiographic results equivalent to those for patients without glenoid bone loss (Walch A1) treated with a non-augmented component. There is a greater risk of CPO in patients with moderate-to-severe B3 glenoid pathology with this stepped augmented glenoid component. Longer follow-up will help define the clinical implications of CPO over time. Level of Evidence: Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.
1 July 2016 in Journal of Shoulder and Elbow Surgery
Background: There has been concern regarding the fixation of anterior cruciate ligament reconstruction, with soft tissue grafts being strong and stiff enough to allow for early accelerated postoperative rehabilitation. Therefore, some have recommended supplementary fixation for soft tissue tibia interference screw fixation with a staple, to improve the strength and stiffness of the fixation. Unfortunately, with staple supplementation, there is a risk for symptomatic hardware, which may require a second surgery to remove the staple.
Background: The purpose of this study was to evaluate glenoid component position and radiolucency following anatomic total shoulder arthroplasty (TSA) using sequential 3-dimensional computed tomography (3D CT) analysis. Methods: In a series of 152 patients (42 Walch A1, 16 A2, 7 B1, 49 B2, 29 B3, 3 C1, 3 C2, and 3 D glenoids) undergoing anatomic TSA with a polyethylene glenoid component, sequential 3D CT analysis was performed preoperatively (CT1), early postoperatively (CT2), and at a minimum 2-year follow-up (CT3). Glenoid component shift was defined as a change in component version or inclination of ≥3° from CT2 to CT3. Glenoid component central anchor peg osteolysis (CPO) was assessed at CT3. Factors associated with glenoid component shift and CPO were evaluated. Results: Glenoid component shift occurred from CT2 to CT3 in 78 (51%) of the 152 patients. CPO was seen at CT3 in 19 (13%) of the 152 patients, including 15 (19%) of the 78 with component shift. Walch B2 glenoids with a standard component and glenoids with higher preoperative retroversion were associated with a higher rate of shift, but not of CPO. B3 glenoids with an augmented component and glenoids with greater preoperative joint-line medialization were associated with CPO, but not with shift. More glenoid component joint-line medialization from CT2 to CT3 was associated with higher rates of shift and CPO. A greater absolute change in glenoid component inclination from CT2 to CT3 and a combined absolute glenoid component version and inclination change from CT2 to CT3 were associated with CPO. Neither glenoid component shift nor CPO was associated with worse clinical outcomes. Conclusions: Postoperative 3D CT analysis demonstrated that glenoid component shift commonly occurs following anatomic TSA, with increased inclination the most common direction. Most (81%) of the patients with glenoid component shift did not develop CPO. Longer follow-up is needed to determine the relationships of glenoid component shift and CPO with loosening over time. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.