Marko Petric

Marko Petric

Auto-generated profile, based on publicly available information

Marko Petric

Jozef Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 November 2015 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
MPMarko Petric
Marko Petric
MKMatjaž Kavčič
Matjaž Kavčič
Kα X-ray emission spectra from a series of phosphorus, sulfur, and chlorine containing compounds covering the full range of oxidation states were measured employing high energy resolution proton induced X-ray emission (PIXE) spectroscopy in the tender X-ray range.

13 May 2016 in Inorganic Chemistry
Verified
Journal Article
Closed access
MPMarko Petric
Marko Petric
RBRok Bohinc
Rok Bohinc
KBKlemen Bucar
Klemen Bucar
SNStanisław H. Nowak
Stanisław H. Nowak
MŽMatjaž Žitnik
Matjaž Žitnik
MKMatjaž Kavčič
Matjaž Kavčič

5 July 2021 in Chemical Communications
Verified
Journal Article
Closed access
PDF file
MPMarko Petric
Marko Petric
ARAva Rajh
Ava Rajh
AVAlen Vizintin
Alen Vizintin
STSara Drvarič Talian
Sara Drvarič Talian
RDRobert Dominko
Robert Dominko
MKMatjaž Kavčič
Matjaž Kavčič
In this work, valence-to-core (VtC) Kβ sulfur X-ray emission spectroscopy (XES) was used to perform quantitative analysis of different sulfur compounds produced in a lithium sulfur (Li–S) battery during discharge. The analysis is based on the theoretical sulfur Kβ XES spectra obtained from ab initio quantum chemical calculations based on density functional theory. The emphasis is given to the Kβ sulfur XES spectra of the polysulfide molecules (Li2Sx, x = 2,⋯,8) produced electrochemically within the Li–S battery. Ab initio molecular dynamics calculations are used further to calculate also the Kβ spectra of Li2Sx dissolved in a model solvent. Calculated spectra were directly compared with the experimental ones collected with a Johansson type tender XES spectrometer on laboratory synthesized Li2Sx reference standards and pre-cycled battery cathodes. These results demonstrate that sulfur VtC XES can be used effectively to quantitatively analyze electrochemical sulfur conversion, also in a smaller laboratory without the need for large scale synchrotron facilities.

16 March 2022 in The Journal of Physical Chemistry C
Verified
Journal Article
Open access
ARAva Rajh
Ava Rajh
IAIztok Arčon
Iztok Arčon
KBKlemen Bučar
Klemen Bučar
MŽMatjaž Žitnik
Matjaž Žitnik
MPMarko Petric
Marko Petric
MKMatjaž Kavčič
Matjaž Kavčič
X-ray Raman spectroscopy (XRS) is an emerging spectroscopic technique that utilizes inelastic scattering of hard X-rays to study X-ray absorption edges of low Z elements in bulk material. It was used to identify and quantify the amount of carbonyl bonds in a cathode sample, in order to track the redox reaction inside metal–organic batteries during the charge/discharge cycle. XRS was used to record the oxygen K-edge absorption spectra of organic polymer cathodes from different multivalent metal–organic batteries. The amount of carbonyl bond in each sample was determined by modeling the oxygen K-edge XRS spectra with the linear combination of two reference compounds that mimicked the fully charged and the fully discharged phases of the battery. To interpret experimental XRS spectra, theoretical calculations of oxygen K-edge absorption spectra based on density functional theory were performed. Overall, a good agreement between the amount of carbonyl bond present during different stages of battery cycle, calculated from linear combination of standards, and the amount obtained from electrochemical characterization based on measured capacity was achieved. The electrochemical mechanism in all studied batteries was confirmed to be a reduction of double carbonyl bond and the intermediate anion was identified with the help of theoretical calculations. X-ray Raman spectroscopy of the oxygen K-edge was shown to be a viable characterization technique for accurate tracking of the redox reaction inside metal–organic batteries.

8 September 2023 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
SFStjepko Fazinić
Stjepko Fazinić
IMIva Bozicevic Mihalic
Iva Bozicevic Mihalic
AMAnja Mioković
Anja Mioković
MRMauricio Rodriguez Ramos
Mauricio Rodriguez Ramos
MPMarko Petric
Marko Petric
Kα X-ray emission induced by 2 MeV H and 3 MeV He ions in thick Al metal, Al 2 O 3 , Al 2 S 3 , AlN, and AlPO 4 was measured using a wavelength-dispersive spectrometer with a flat diffraction crystal to study the chemical sensitivity of related X-ray spectra.

16 July 2019 in Environmental engineering
Verified
Journal Article
Open access
PDF file
MPMarko Petric
Marko Petric
FDFilip Dodigovic
Filip Dodigovic
MTMateo Topić
Mateo Topić
LRLucija Radetic
Lucija Radetic
PMPetar Mrakužić
Petar Mrakužić
Ivana GrčićIvana Grčić
Ivana Grčić
In order to evaluate the efficacy of ammonia photocatalysis, it is necessary to continuously monitor its concentration during the process. This paper presents ammonia concentration monitoring using a low cost (non-professional) electronic device. The device is based on an open source electronic platform, and it is composed of the MQ-137 ammonia detection sensor, connected to the Croduino Basic 2 board. Sensitive material of the sensor is a metal oxide (SnO2). The change in the ammonia concentration causes a change in the electrical resistance, which is measured and used for the ammonia concentration estimation. Four measurements, with ammonia concentration ranging from 0-500 ppm were performed in the controlled environment. With the purpose of the device calibration and repeatability test, along with a low-cost device, the monitoring was carried out also with a professional device, Geotech GA5000 gas analyser. Using the information provided in the sensor datasheet, together with the measured data, the measurement error of the low-cost device was assessed. After calibration, ammonia concentrations measured using a low-cost device, are consistent with those obtained from the professional device.