Background: Terminal sterilization is generally preferred for parenteral products when the formulation and container can tolerate the process. Retatrutide is a thermolabile peptide, making conventional moist heat unsuitable and creating a need to evaluate a nonthermal terminal modality. Objective: To establish an in silico decision framework for electron beam terminal sterilization of a 10 mg/mL retatrutide multidose cartridge and to define a stability indicating reversed phase high performance liquid chromatography method for post irradiation control. Methods: Moist heat, dry heat, ethylene oxide, sterile filtration with aseptic processing, and electron beam irradiation were compared by product specific criteria. A model electron accelerator configuration used a UELR-10-15-S-1 unit No. 128170401 at 9.5 MeV, 1.19 mA, 50 cm scan width, and 1.75 m/min conveyor speed. Three virtual batches were assigned dose maps, bioburden distributions, verification tests, sterility outcomes, and RP HPLC results. A Monte Carlo survivor model estimated the probability of a nonsterile unit. Results: The model selected electron beam irradiation as a candidate terminal method, subject to experimental qualification. Simulated minimum and maximum absorbed doses were 15.1 to 15.4 kGy and 18.1 to 18.4 kGy, respectively. All three virtual batches met the model criterion of a probability of a nonsterile unit not greater than 10 to the power of minus 6. Post irradiation retatrutide assay was 97.2 to 97.8 percent, while total related substances were 2.10 to 2.39 percent. Conclusions: The simulated dataset supports a bounded development hypothesis but does not demonstrate sterility, peptide integrity, process validation, or suitability for human use. Accelerator electrical settings do not define absorbed dose. Confirmatory work requires calibrated dose mapping, microbiological dose substantiation, validated RP HPLC and orthogonal structural and biological methods.