31 October 2023 in IEEE Transactions on Medical Robotics and Bionics
Despite medical treatment focused on addressing walking disability, many millions of people with neurological conditions, like cerebral palsy (CP), struggle to maintain independent mobility. Lower limb exoskeletons and exosuits may hold potential for augmenting walking ability. However, it remains unknown whether these wearable robots are safe and beneficial for use outside of highly controlled laboratory environments, the demonstration of which is necessary for clinical translation. Here, we show that a lightweight, portable, ankle exoskeleton with an adaptable one-size-works-for-all assistance controller can improve energy efficiency and walking speed for individuals with CP spanning a wide spectrum of lower limb impairment in a multi-terrain real-world environment. Tested on an outdoor walking route with level, sloped, and stair terrain, robotic assistance resulted in a 15–18% (p ${=}$ 0.013–0.026) reduction in estimated energy cost and a 7–8% (p ${=}$ 0.001–0.004) increase in average walking speed across “shorter” 6-minute and “longer” 20-minute walking durations relative to unassisted walking. This study provides evidence that wearable robots may soon improve mobility in neighborhood, school, and community settings for individuals with CP.
9 October 2024 in IEEE Robotics and Automation Letters
Robotic exoskeletons are increasingly being used for gait rehabilitation in individuals with neuromuscular disorders, such as cerebral palsy (CP). A primary rehabilitation goal for those with CP is to improve ankle push-off power, which is crucial for enhancing gait function. Previous research suggests that interleaving assistance and resistance within the same training session may improve certain aspects of gait, such as joint trajectories and torque profiles. This feasibility study sought to investigate the efficacy of priming the plantar flexor muscles with ankle exoskeleton plantar flexor assistance to facilitate increased ankle push-off power during subsequent resisted gait training bouts in individuals with CP. Specifically, we hypothesized that providing plantar-flexor assistance immediately prior to walking with resistance would increase peak biological ankle power and muscle activity compared to walking with resistance alone. We found that peak biological ankle power increased by 25% (p = 0.021) during assistance-primed resisted walking compared to the baseline resisted walking trail. While ankle angular velocity also increased alongside power, there was no significant difference in plantar flexor muscle activity, suggesting more efficient recruitment. These results contribute to our overarching goal of optimizing robotic exoskeleton interventions, potentially leading to the future design of more effective gait rehabilitation strategies
14 July 2025 in Annals of Biomedical Engineering
27 January 2025 in IEEE Transactions on Biomedical Engineering
Objective: Powered ankle exoskeletons with biofeedback systems have proven effective at improving ankle plantar flexor muscle recruitment and push-off power in individuals with cerebral palsy (CP). However, their clinical translation and feasibility for at-home training remain limited. This study sought to design an unpowered wearable ankle device with spring resistance combined with a gamified ankle power biofeedback system. Our primary goal was to validate the device's ability to increase plantar flexor muscle recruitment and push-off power relative to baseline, and ensure that these improvements were comparable to those achieved with motorized resistance. Methods: Seven ambulatory individuals with CP completed walking sessions with (1) a powered ankle exoskeleton with motorized resistance, (2) our novel ankle device with spring resistance, and (3) shoes only (baseline); Both devices utilized the same biofeedback system. Results: Relative to baseline, both the motorized and spring resistance increased peak (48%, p < 0.05) and mean (43–45%, p < 0.05) soleus activation and mean (37–39%, p < 0.05) medial gastrocnemius activation. No differences in muscle recruitment between spring and motorized devices were observed. Walking with spring resistance increased average ankle push-off positive power by 22% (p = 0.003) compared to motorized resistance and by 23% (p = 0.013) compared to baseline. Conclusion: An ankle device providing targeted spring resistance with ankle power biofeedback can effectively improve push-off muscle recruitment and power in individuals with CP. Significance: This supports future research studying outcomes following training with spring-based ankle resistance devices that lower barriers for clinical translation.