Laszlo Romanszky

Laszlo Romanszky

Auto-generated profile, based on publicly available information

Laszlo Romanszky

Dental technicians, Artifex Dentis Kft. Révay utca 12, H-1065 Budapest, Hungary

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 December 2022 in Journal of Dentistry
Verified
Journal Article
Open access
DBDaniel Borbola
Daniel Borbola
GBGabor Berkei
Gabor Berkei
BSBotond Simon
Botond Simon
LRLaszlo Romanszky
Laszlo Romanszky
GSGyorgy Sersli
Gyorgy Sersli
JVJanos Vag
Janos Vag
The study aimed to compare the precision of ATOS industrial, 3ShapeE4, MeditT710, CeramillMap400, CSNeo, PlanScanLab desktop, and Mediti700 intraoral scanners. The second aim was to compare the trueness of Mediti700 assessed by ATOS and desktop scanners. Four plastic dentate models with 7-12 abutments prepared for complete arch fixed dentures were scanned by all scanners three times. Scans were segmented to retain only the abutments. The precision and trueness were calculated by superimposing scans with the best-fit algorithm. The mean absolute distance was calculated between the scan surfaces. The precision was calculated based on the 12 repeats. Trueness was evaluated by superimposing the desktop and IOS scans to the industrial scans. IOS was also aligned with the two most accurate desktop scanners. The precision of 3ShapeE4 and MeditT710 (3-4μm) was only slightly lower than that of ATOS (1.7μm, p<0.001) and significantly higher than CeramillMap400, CSNeo, and PlanScanLab (6-10 μm, p<0.001). The trueness was the highest for the 3Shape E4 (12-13 μm) and Medit T710 (13-16 μm) without significant difference. They were significantly better than CeramillMap400, CSNeo, and PlanScanLab (22-31μm, p<0.001). Accordingly, the Mediti700 trueness was evaluated by ATOS, 3ShapeE4, and MeditT710. The three trueness was not significantly different; ATOS (23-26 μm), 3Shape E4 (22-25 μm), and Medit T710 (20-23 μm). All desktop scanners had the acceptable accuracy required for a complete arch-fixed prosthesis. The 3Shape E4 and the Medit T710 might be used as reference scanners for studying IOS accuracy. 3ShapeE4, MeditT710, CeramillMap400, CSNeo, PlanScanLab laboratory, and Mediti700 intraoral scanners can be used for the prosthetic workflow in a complete arch. 3ShapeE4 and the MeditT710 could be used to test the accuracy of various phases of a laboratory workflow, replacing the industrial scanners.

31 July 2024 in Journal of Dentistry
Verified
Journal Article
Open access
DBDaniel Borbola
Daniel Borbola
AMAkos Mikolicz
Akos Mikolicz
LRLaszlo Romanszky
Laszlo Romanszky
GSGyorgy Sersli
Gyorgy Sersli
MDMichael DeFee
Michael DeFee
JVJanos Vag
Janos Vag
This study compared the accuracy of seven intraoral scanners (IOS) by the virtual-fit method. Four maxillary arches with tooth abutments were scanned with an industrial reference scanner (n=1) and by Aoralscan3, EmeraldS, Helios600, Lumina, Mediti700, Primescan, and Trios5 IOSs (each n=12). Two complete-arch fixed frameworks were designed on each IOS scan with a 70 µm (group 70) and a 90 µm internal cement space (group 70+20, additional 20 µm at the margin). The virtual-fit method was comprised of superimposing the framework designs onto the reference scan using a non-penetrating algorithm simulating the clinical try-in. Internal and marginal gaps were measured. Precision was estimated by the mean absolute errors (MAE). In group 70, Mediti700 (43 µm), Primescan (42 µm), and EmeraldS were in the best homogenous subset for the marginal gap, followed by the Lumina (67 µm), Aoralscan3 (70 µm), and Trios5 (70 µm), whereas Helios600 (118 µm) was in the third subset. Based on the MAE at the margin, Mediti700, Trios5, and EmeraldS were in the first-best homogenous subset, followed by Primescan. Lumina and Helios600 were in the third subset, and Aoralscan3 was in the fourth subset. In group 70+20, the marginal gap was significantly decreased for Lumina and Aoralscan3, whereas MAE significantly decreased for EmeraldS and Aoralscan3. The rank of IOSs was similar for the internal gap. EmeraldS, Mediti700, Primescan, and Trios5 meet the marginal and internal fit criteria for fixed tooth-borne complete arch restorations. Increasing the cement space during design could enhance restoration fit. The virtual-fit alignment method can effectively evaluate the accuracy of different intraoral scanners, offering valuable clinical guidance for distinguishing among them. Recent software and hardware versions of long-standing IOS manufacturers are suitable for fabricating complete arch restoration.

16 July 2026 in Journal of Dentistry
Verified
Journal Article
Open access
RDRoland Daubner
Roland Daubner
VNVivien Nazar
Vivien Nazar
LRLaszlo Romanszky
Laszlo Romanszky
GSGyorgy Sersli
Gyorgy Sersli
DBDaniel Borbola
Daniel Borbola
JVJanos Vag
Janos Vag
To evaluate the effect of restoration span on scanner-related restoration fit obtained with six intraoral scanners and one dental laboratory scanner. A maxillary resin model with eight abutments was scanned with an ATOSQ reference scanner and subsequently with the Aoralscan Elite, Mediti900, Primescan2, R2i3, RunyesV6, and TRIOS6 intraoral scanners, and the AutoScan-DSEXPro(H) laboratory scanner (n=12 per test scanner). Complete-arch, four-unit bridge, and single-unit restorations were digitally designed. The designed restoration meshes were superimposed on the reference scan using a virtual-fit approach. Marginal gap (MG) and absolute marginal discrepancy (AMD) were calculated for each scanner in the metrology software. Statistical analysis was performed using generalized linear mixed models. Mean MG ranged from 15-30 µm for single crowns, 16-44 µm for bridges, and 37-91 µm for complete-arch restorations. MG was significantly higher for bridges than for single crowns for all scanners except AutoScan-DSEXPro(H) and Aoralscan Elite. Complete-arch restorations showed significantly higher MG and AMD than bridges for all scanners, although mean MG remained below the clinically derived, model-based threshold of 100 µm. However, several R2i3 and TRIOS6 scans exceeded this MG threshold. Mean AMD exceeded the threshold for RunyesV6, R2i3, and TRIOS6 in complete-arch restorations. Restoration span is a critical determinant of scanning accuracy, particularly when moving from four-unit bridges to complete-arch restorations, even for the laboratory scanner. The virtual-fit method enables robust, clinically interpretable comparison of scanner accuracy across restoration types. Intraoral scanner selection should consider the intended restoration span. While all evaluated scanners performed well for short-span restorations, only some maintained high accuracy for complete-arch tooth-borne restorations. Because these findings are based on an in vitro study, scanners with lower complete-arch accuracy should be used with caution in clinical practice.