Jeanne Hersant

Jeanne Hersant

Auto-generated profile, based on publicly available information

Jeanne Hersant

Department of Vascular Medicine, University Hospital of Angers, France

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 January 2023 in European Journal of Vascular and Endovascular Surgery
Verified
Journal Article
Closed access
OEOlivier Espitia
Olivier Espitia
FDFrédéric Douane
Frédéric Douane
JHJeanne Hersant
Jeanne Hersant
FAFabrice Abbadie
Fabrice Abbadie
JSJonathan Sobocinski
Jonathan Sobocinski
BMBlandine Maurel
Blandine Maurel

1 July 2025 in Hypertension
Verified
Journal Article
Closed access
VKVimarsha Kodithuwakku
Vimarsha Kodithuwakku
MBMonique Breslin
Monique Breslin
JHJeanne Hersant
Jeanne Hersant
RBRosa-Maria Bruno
Rosa-Maria Bruno
PBPierre Boutouyrie
Pierre Boutouyrie
YCYouth Vascular Consortium collaborators
Youth Vascular Consortium collaborators
BACKGROUND: Aortic pulse wave velocity (PWV) is an indicator of vascular aging and has proven to be effective in adult cardiovascular risk assessment. To use it in young people to identify those who may be at increased cardiovascular disease risk, reference values need to be determined. The Youth Vascular Consortium is a large, international database which was established to investigate vascular aging in youth. Using data from the Youth Vascular Consortium, this study aimed to develop reference values for aortic PWV in healthy young people. METHODS: This is a retrospective, multicenter study. Data on demographics, anthropometric, biochemical, and vascular aging measures from participants aged 1 year to 40 years were harmonized. Generalized additive models were used to derive percentile curves for PWV and predicted percentiles at years of age were reported by sex, continent, and device. RESULTS: Data from 19 930 participants (mean age=17 years, 51% women, 71% European), classified as healthy based on blood pressure, body mass index, serum glucose, and cholesterol levels, were included to construct the reference values. Six devices were used to assess aortic PWV (29% SphygmoCor). Device-specific percentile curves for aortic PWV were constructed, and an increasing trend was identified for both sexes with age. CONCLUSIONS: This study provided reference values for aortic PWV assessed with 6 devices for healthy young people by age and sex. These percentiles may be applied clinically to identify youth with impaired vascular aging and, thus, those who may be at risk of developing overt cardiovascular disease in the future.

12 March 2024 in Vascular Medicine
Verified
Journal Article
Closed access
JTJean-Eudes Trihan
Jean-Eudes Trihan
MCMagali Croquette
Magali Croquette
JHJeanne Hersant
Jeanne Hersant
RPRomain Prigent
Romain Prigent
CFCedric Fontaine
Cedric Fontaine
DLDamien Lanéelle
Damien Lanéelle
Introduction: Maximal acceleration time of distal arteries of the foot (AT max ) is correlated to ankle–brachial index (ABI) and toe–brachial index (TBI), and seems very promising in diagnosing severe peripheral artery disease (PAD) and especially critical limb-threatening ischemia (CLTI). Our goal was to confirm the cut-off value of 215 ms to predict a toe pressure (TP) ⩽ 30 mmHg. Methods: A 4-month retrospective study was conducted on patients addressed for suspicion of PAD. Demographic data, ABI, TBI, and Doppler ultrasound scanning parameters of the dorsal pedis and lateral plantar arteries (DPA and LPA) were recorded. Results: A total of 137 patients with 258 lower limbs were included. AT max was highly correlated to TBI ( r = −0.89, p < 0.001). With the cut-off value of 215 ms, AT max was effective to diagnose TP ⩽ 30 mmHg with a sensitivity of 93% [95% CI 77–99], a specificity of 96% [95% CI 92–98], a positive predictive value of 73% [95% CI 56–86], a negative predictive value of 99% [95% CI 97–100], and an area under the receiver operating characteristics curve of 0.99 [95% CI 0.98–1.00]. AT max also showed promising results to rule out PAD in healthy patients. Conclusion: AT max is a reliable diagnostic tool to diagnose low TP and could be a new easily performed hemodynamic criterion for diagnosis of CLTI.

28 February 2020 in Clinical Physiology and Functional Imaging
Verified
Journal Article
Closed access
PDF file
WSWendsèndaté Yves Sempore
Wendsèndaté Yves Sempore
PRPierre Ramondou
Pierre Ramondou
JHJeanne Hersant
Jeanne Hersant
MFMathieu Feuilloy
Mathieu Feuilloy
CGCeline Guilleron
Celine Guilleron
PAPierre Abraham
Pierre Abraham

1 July 2025 in Vasa
Verified
Journal Article
Closed access
GBGiacomo Buso
Giacomo Buso
JHJeanne Hersant
Jeanne Hersant
SKSanjiv Keller
Sanjiv Keller
IKIgli Kalaja
Igli Kalaja
PBPaola Bigolin
Paola Bigolin
LMLucia Mazzolai
Lucia Mazzolai
Summary: The new guidelines for the management of peripheral arterial and aortic diseases (PAAD) from the European Society of Cardiology and endorsed by the European Society of Vascular Medicine (ESVM), emphasize on a comprehensive and multidisciplinary approach focusing on prevention, diagnosis, treatment, and follow-up of patients with a wide range of PAAD, including lower extremity peripheral arterial disease (PAD). The aim of this summary, focusing on PAD and coordinated by the Young Academy of ESVM, is to provide young angiologists with the fundamental principles of these guidelines and to assist them in navigating their everyday clinical practice. PAD diagnosis relies on objective evaluation of flow/oxygen reduction at rest, with arterial ultrasound as the first imaging modality to confirm the presence of arterial lesions. The main goals of PAD management are not only to improve functioning and prevent the occurrence of adverse events at the lower limb level, but also to reduce the overall atherosclerotic burden and achieve the general well-being of patients. To this end, traditional and nontraditional cardiovascular risk factors need to be properly addressed through lifestyle changes and tailored drug therapies. For patients with exertional limb symptoms, supervised exercise training is recommended. Interventional treatment is indicated for limb salvage in patients with chronic limb threatening ischemia and may also be discussed in a multidisciplinary setting in less severe patients with persisting symptoms and reduced quality of life after a minimum period of optimal medical treatment including exercise therapy. For trainees or young specialists in Angiology/Vascular Medicine, these guidelines provide essential elements to improve patient management, encourage interdisciplinary collaboration, and ensure an integrated approach to vascular diseases.

1 April 2022 in Ultrasonography
Verified
Journal Article
Open access
PDF file
JHJeanne Hersant
Jeanne Hersant
PRPierre Ramondou
Pierre Ramondou
DDDelphine Douillet
Delphine Douillet
SAStanislas Abrard
Stanislas Abrard
PVPatrick Vandeputte
Patrick Vandeputte
SHSamir Henni
Samir Henni
Purpose: This study investigated the correlations of hemodynamic parameters measured to quantify stenosis between the gold-standard duplex ultrasonography and the dual-gate Doppler mode.Methods: Patients examined due to suspicion of carotid artery stenosis or for surveillance of known stenosis were invited to participate in this prospective single-center study. Upon acceptance, the hemodynamic characteristics of the carotid arteries were determined successively in standard duplex and dual-gate Doppler modes. The correlations between the two modes were analyzed by computing Pearson coefficients (r2) and Lin concordance coefficients (ρc). The degree of agreement between the two methods was visualized using Bland-Altman graphical representations.Results: The correlation between internal carotid artery peak systolic velocity measured by standard duplex ultrasonography and dual-gate Doppler mode was good (r2=0.642). The same high level of correlation was observed for the carotid ratio (r2=0.544). However, the Bland-Altman graphical representation and the Lin concordance coefficients (ρc=0.75 and ρc=0.74 for the internal carotid artery peak systolic velocity and carotid ratio, respectively) showed that a lack of precision generated some discrepancies between the two measurement methods.Conclusion: Although some discrepancies were observed, the hemodynamic measurements were closely correlated between the two ultrasonography modes. Therefore, the dual-gate Doppler mode may have obvious advantages over conventional ultrasonography, offering interesting development possibilities.