Annika Brüske

Annika Brüske

Auto-generated profile, based on publicly available information

Annika Brüske

Institut für Mineralogie, Leibniz Universität Hannover, Germany

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2020 in Geochimica et Cosmochimica Acta
Verified
Journal Article
Closed access
ABA. Brüske
A. Brüske
SWS. Weyer
S. Weyer
MZM.-Y. Zhao
M.-Y. Zhao
NPN.J. Planavsky
N.J. Planavsky
AWA. Wegwerth
A. Wegwerth
TLT.W. Lyons
T.W. Lyons

1 November 2019 in Geochimica et Cosmochimica Acta
Verified
Journal Article
Closed access
GAGülüm Albut
Gülüm Albut
Balz Samuel KamberBalz Samuel Kamber
Balz Samuel Kamber
ABAnnika Brüske
Annika Brüske
NBNicolas J. Beukes
Nicolas J. Beukes
ASAlbertus J.B. Smith
Albertus J.B. Smith
RSRonny Schoenberg
Ronny Schoenberg

1 January 2018 in Palaeogeography, Palaeoclimatology, Palaeoecology
Verified
Journal Article
Closed access
AWAntje Wegwerth
Antje Wegwerth
SESebastian Eckert
Sebastian Eckert
ODOlaf Dellwig
Olaf Dellwig
BSBernhard Schnetger
Bernhard Schnetger
SSSilke Severmann
Silke Severmann
HBHans-Jürgen Brumsack
Hans-Jürgen Brumsack

1 December 2019 in Chemical Geology
Verified
Journal Article
Closed access
SSStephan Schuth
Stephan Schuth
ABAnnika Brüske
Annika Brüske
SHSimon V. Hohl
Simon V. Hohl
SJShao-Yong Jiang
Shao-Yong Jiang
AMAnn-Katrin Meinhardt
Ann-Katrin Meinhardt
SWStefan Weyer
Stefan Weyer

7 June 2017 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
MWMona Weyrauch
Mona Weyrauch
MOMartin Oeser
Martin Oeser
ABAnnika Brüske
Annika Brüske
SWStefan Weyer
Stefan Weyer
In this study, an in situ technique for high-precision determination of Ni stable isotope ratios by femtosecond-laser ablation-multicollector-ICP-MS (fs-LA-MC-ICP-MS) was developed. With this technique, the Ni isotope compositions of Ni-bearing steels (NIST RM-1226 and BAM D 184-1) and a Ni-rod (standard 10209 from MAC) were determined, both by fs-LA-MC-ICP-MS analyses and by solution MC-ICP-MS, the latter in order to verify the results of the in situ analyses. The LA-MC-ICP-MS analyses revealed that all analyzed standard materials were homogeneous within analytical uncertainties and may thus be suitable as external standards for Ni isotope determination by in situ analysis of metal phases and sulfides. Bulk solution MC-ICP-MS and LA-MC-ICP-MS analyses of these metals agreed within their analytical uncertainties of 0.03‰ for the solution analyses and <0.1‰ (2SD, over 12 months) for the LA-MC-ICP-MS analyses. These results imply that the accuracy of the in situ analyses of metals is better than 0.1‰. The average of four solution nebulization analyses of the Ni-rod and D 184-1, and of 16 analyses of the NIST RM-1226 material, revealed δ62Ni values of −0.26‰, 0.12‰, and −0.28‰ relative to NIST SRM-986, respectively. In order to show the applicability and potential of the presented method, the Ni and Fe isotope compositions of a kamacite–taenite interface in IAB iron meteorite Canyon Diablo were determined by fs-LA-MC-ICP-MS analyses. The isotope profile reveals lighter Fe isotopes in kamacite than in taenite, while the Ni isotope composition is vice versa. Evolution of the isotope signals along the interface of these metal phases strongly points to diffusion-driven fractionation of Fe and Ni isotopes during the formation of kamacite by the replacement of taenite. Due to Fe–Ni exchange diffusion between taenite and kamacite and the generally faster diffusion of light isotopes compared to heavy isotopes, the remaining taenite is left with heavier Fe and lighter Ni isotope compositions than the newly formed kamacite. Demonstration of such detailed information about the diffusion processes in the kamacite–taenite system was not possible before, due to the lack of an appropriate high-precision and high spatial resolution technique for in situ Ni isotope analyses.