Atul Anand

Atul Anand

Auto-generated profile, based on publicly available information

Atul Anand

University of Edinburgh

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2015 in The Lancet
Verified
Journal Article
Open access
ASAnoop S V Shah
Anoop S V Shah
AAAtul Anand
Atul Anand
YSYader Sandoval
Yader Sandoval
KLKuan Ken Lee
Kuan Ken Lee
SSStephen W Smith
Stephen W Smith
NMNicholas Linton Mills
Nicholas Linton Mills
Suspected acute coronary syndrome is the commonest reason for emergency admission to hospital and is a large burden on health-care resources. Strategies to identify low-risk patients suitable for immediate discharge would have major benefits. We did a prospective cohort study of 6304 consecutively enrolled patients with suspected acute coronary syndrome presenting to four secondary and tertiary care hospitals in Scotland. We measured plasma troponin concentrations at presentation using a high-sensitivity cardiac troponin I assay. In derivation and validation cohorts, we evaluated the negative predictive value of a range of troponin concentrations for the primary outcome of index myocardial infarction, or subsequent myocardial infarction or cardiac death at 30 days. This trial is registered with ClinicalTrials.gov (number NCT01852123). 782 (16%) of 4870 patients in the derivation cohort had index myocardial infarction, with a further 32 (1%) re-presenting with myocardial infarction and 75 (2%) cardiac deaths at 30 days. In patients without myocardial infarction at presentation, troponin concentrations were less than 5 ng/L in 2311 (61%) of 3799 patients, with a negative predictive value of 99·6% (95% CI 99·3-99·8) for the primary outcome. The negative predictive value was consistent across groups stratified by age, sex, risk factors, and previous cardiovascular disease. In two independent validation cohorts, troponin concentrations were less than 5 ng/L in 594 (56%) of 1061 patients, with an overall negative predictive value of 99·4% (98·8-99·9). At 1 year, these patients had a lower risk of myocardial infarction and cardiac death than did those with a troponin concentration of 5 ng/L or more (0·6% vs 3·3%; adjusted hazard ratio 0·41, 95% CI 0·21-0·80; p<0·0001). Low plasma troponin concentrations identify two-thirds of patients at very low risk of cardiac events who could be discharged from hospital. Implementation of this approach could substantially reduce hospital admissions and have major benefits for both patients and health-care providers. British Heart Foundation and Chief Scientist Office (Scotland).

20 March 2018 in Circulation
Verified
Journal Article
Open access
PDF file
ACAndrew Chapman
Andrew Chapman
ASAnoop S. V. Shah
Anoop S. V. Shah
KLKuan Ken Lee
Kuan Ken Lee
AAAtul Anand
Atul Anand
OFOliver Francis
Oliver Francis
NMNicholas Linton Mills
Nicholas Linton Mills
Background—Type 2 myocardial infarction and myocardial injury are common in clinical practice, but long-term consequences are uncertain. We aimed to define long-term outcomes and explore risk stratification in patients with type 2 myocardial infarction and myocardial injury. Methods—We identified consecutive patients (n=2,122) with elevated cardiac troponin I concentrations (≥0.05 μg/L) at a tertiary cardiac center. All diagnoses were adjudicated as per the Universal Definition of Myocardial Infarction. The primary outcome was all-cause death. Secondary outcomes included major adverse cardiovascular events (MACE; non-fatal myocardial infarction or cardiovascular death) and non-cardiovascular death. To explore competing risks, cause-specific hazard ratios were obtained using Cox regression models. Results—The adjudicated index diagnosis was type 1 or type 2 myocardial infarction or myocardial injury in 1,171 (55.2%), 429 (20.2%) and 522 (24.6%) patients, respectively. At five years, all-cause death rates were higher in those with type 2 myocardial infarction (62.5%) or myocardial injury (72.4%) compared with type 1 myocardial infarction (36.7%). The majority of excess deaths in those with type 2 myocardial infarction or myocardial injury were due to non-cardiovascular causes (HR 2.32, 95%CI 1.92-2.81, versus type 1 myocardial infarction). Despite this, the observed crude MACE rates were similar between groups (30.6% versus 32.6%), with differences apparent after adjustment for co-variates (HR 0.82, 95%CI 0.69-0.96). Coronary heart disease was an independent predictor of MACE in those with type 2 myocardial infarction or myocardial injury (HR 1.71, 95%CI 1.31-2.24). Conclusions—Despite an excess in non-cardiovascular death, patients with type 2 myocardial infarction or myocardial injury have a similar crude rate of major adverse cardiovascular events to those with type 1 myocardial infarction. Identifying underlying coronary heart disease in this vulnerable population may help target therapies that could modify future risk.

15 February 2006 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Closed access
NMNicholas Linton Mills
Nicholas Linton Mills
NANadia Amin
Nadia Amin
SRSimon D. Robinson
Simon D. Robinson
AAAtul Anand
Atul Anand
JDJohn Davies
John Davies
DNDavid E. Newby
David E. Newby
Rationale: Increased exposure to particulate air pollution (PM10) is a risk factor for death and hospitalization with cardiovascular disease. It has been suggested that the nanoparticulate component of PM10 is capable of translocating into the circulation with the potential for direct effects on the vasculature. Objective: The study's aim was to determine the extent to which inhaled technetium-99m (99mTc)–labeled carbon nanoparticles (Technegas) were able to access the systemic circulation. Methods and Main Results: Ten healthy volunteers inhaled Technegas and blood samples were taken sequentially over the following 6 h. Technegas particles were 4–20 nm in diameter and aggregated to a median particle diameter of approximately 100 nm. Radioactivity was immediately detected in blood, with levels increasing over 60 min. Thin-layer chromatography of whole blood identified a species that moved with the solvent front, corresponding to unbound 99mTc-pertechnetate, which was excreted in urine. There was no evidence of particle-bound 99mTc at the origin. γ Camera images demonstrated high levels of Technegas retention (95.6 ± 1.7% at 6 h) in the lungs, with no accumulation of radioactivity detected over the liver or spleen. Conclusions: The majority of 99mTc-labeled carbon nanoparticles remain within the lung up to 6 h after inhalation. In contrast to previous published studies, thin-layer chromatography did not support the hypothesis that inhaled Technegas carbon nanoparticles pass directly from the lungs into the systemic circulation.

23 March 2011 in JAMA
Verified
Journal Article
Open access
PDF file
NMNicholas Linton Mills
Nicholas Linton Mills
ACAntonia M. D. Churchhouse
Antonia M. D. Churchhouse
KLKuan Ken Lee
Kuan Ken Lee
AAAtul Anand
Atul Anand
DGDavid Gamble
David Gamble
DNDavid E. Newby
David E. Newby
Research from JAMA — Implementation of a Sensitive Troponin I Assay and Risk of Recurrent Myocardial Infarction and Death in Patients With Suspected Acute Coronary Syndrome

21 November 2017 in JAMA
Verified
Journal Article
Open access
PDF file
ACAndrew Chapman
Andrew Chapman
KLKuan Ken Lee
Kuan Ken Lee
DMDavid A. McAllister
David A. McAllister
LCLouise Cullen
Louise Cullen
JGJaimi H. Greenslade
Jaimi H. Greenslade
NMNicholas Linton Mills
Nicholas Linton Mills
Chest pain is one of the most common reasons for presentation to hospitals worldwide.1 Despite the majority of patients not having myocardial infarction,2 hospital admission for observation and serial cardiac troponin testing is required in many patients to identify those with and without myocardial infarction.3 Novel strategies to identify low-risk patients at presentation have been proposed to reduce hospital admissions, serial testing, and resource utilization as well as to improve care for patients.4,5

11 November 2020 in Age and Ageing
Verified
Journal Article
Open access
PDF file
ZTZoe Tieges
Zoe Tieges
AMAlasdair M J Maclullich
Alasdair M J Maclullich
AAAtul Anand
Atul Anand
CBClaire Brookes
Claire Brookes
MCMarica Cassarino
Marica Cassarino
RGRose Galvin
Rose Galvin
Objective: Detection of delirium in hospitalised older adults is recommended in national and international guidelines. The 4 ‘A’s Test (4AT) is a short (<2 minutes) instrument for delirium detection that is used internationally as a standard tool in clinical practice. We performed a systematic review and meta-analysis of diagnostic test accuracy of the 4AT for delirium detection. Methods: We searched MEDLINE, EMBASE, PsycINFO, CINAHL, clinicaltrials.gov and the Cochrane Central Register of Controlled Trials, from 2011 (year of 4AT release on the website www.the4AT.com) until 21 December 2019. Inclusion criteria were: older adults (≥65 years); diagnostic accuracy study of the 4AT index test when compared to delirium reference standard (standard diagnostic criteria or validated tool). Methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Pooled estimates of sensitivity and specificity were generated from a bivariate random effects model. Results: Seventeen studies (3,702 observations) were included. Settings were acute medicine, surgery, a care home and the emergency department. Three studies assessed performance of the 4AT in stroke. The overall prevalence of delirium was 24.2% (95% CI 17.8–32.1%; range 10.5–61.9%). The pooled sensitivity was 0.88 (95% CI 0.80–0.93) and the pooled specificity was 0.88 (95% CI 0.82–0.92). Excluding the stroke studies, the pooled sensitivity was 0.86 (95% CI 0.77–0.92) and the pooled specificity was 0.89 (95% CI 0.83–0.93). The methodological quality of studies varied but was moderate to good overall. Conclusions: The 4AT shows good diagnostic test accuracy for delirium in the 17 available studies. These findings support its use in routine clinical practice in delirium detection. PROSPERO Registration number: CRD42019133702.