Zhongyou Li

Zhongyou Li

Auto-generated profile, based on publicly available information

Zhongyou Li

Sichuan Province Biomechanical Engineering Laboratory, Sichuan University, Chengdu 610065, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 July 2020 in Materials
Verified
Journal Article
Open access
PDF file
CCChong Chen
Chong Chen
YXYan Xiong
Yan Xiong
ZLZhongyou Li
Zhongyou Li
CYChen Yu
Chen Yu
Objective: Biodegradable stents (BDSs) represent a new technological development in the field of cardiovascular angioplasty; good flexibility helps stents pass through tortuous vessels during delivery and reduces the amount of damage caused to blood vessels. This study investigates the relationship between flexibility and the geometry of BDS struts. Methods: Four stent struts with different geometry (circular, triangular, hexagonal, and spline curved) and the same links were modeled to evaluate their flexibility via a three-point bending experimental method and a numerical method. Results: The bending state of the four stents was well-balanced. The bending effect of the four stents was different. Under the same conditions, the circular and spline curved stents showed the best bending effects while the hexagonal stent was the worst. However, these differences were not significant. Conclusion: The flexibility of BDSs is related to the geometry of the struts and links; however, the geometry of the struts has less effect on flexibility than the links. The greater the area enclosed by the strut centerline, the better flexibility of the stent.

20 January 2026 in Journal of Biomechanics
Verified
Journal Article
Closed access
JZJiyang Zhang
Jiyang Zhang
LLLingjun Liu
Lingjun Liu
WJWentao Jiang
Wentao Jiang
MZMing Zhang
Ming Zhang
TBTaoping Bai
Taoping Bai
ZLZhongyou Li
Zhongyou Li

1 November 2024 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
CRChang Ruan
Chang Ruan
JZJingyuan Zhou
Jingyuan Zhou
ZZZhuo Zhang
Zhuo Zhang
TLTao Li
Tao Li
LCLu Chen
Lu Chen
CYChen Yu
Chen Yu
Cardiovascular diseases, characterized by high mortality rates, complex etiologies, and challenging prevention and treatment strategies, have become a major focus of public concern. With the advancement of computational numerical simulation technologies, whole-heart modeling has emerged as a crucial direction in cardiovascular engineering research. This review summarizes the progress in numerical simulations of whole-heart models, with a particular emphasis on the modeling and computation of cardiac-related physical fields. Through a retrospective study, this article covers various modeling approaches, including electrophysiological simulations, cardiac mechanics, and fluid–structure interaction models. Advanced theoretical models and numerical techniques are discussed in depth to enhance the accuracy and relevance of the simulations. Currently, numerical simulation techniques for whole-heart modeling have developed a relatively complete theoretical framework to compute key cardiac functions. However, there remains a need for further exploration in multiphysics coupling and high-performance computing to support clinical applications, requiring additional theories and methods. The integration of multiphysics and multiscale modeling is critical for advancing personalized medicine and improving the diagnosis and treatment of cardiovascular diseases. Future research will focus on enhancing computational efficiency and expanding clinical applications.

24 September 2025 in Journal of Thermal Biology
Verified
Journal Article
Closed access
ZLZhongyou Li
Zhongyou Li
TBTaoping Bai
Taoping Bai
WJWentao Jiang
Wentao Jiang
FYFei YAN
Fei YAN
LLLingjun Liu
Lingjun Liu
CCChong Chen
Chong Chen

1 May 2023 in Physics of Fluids
Verified
Journal Article
Open access
PDF file
ZLZhongyou Li
Zhongyou Li
RLRongguang Luo
Rongguang Luo
WJWentao Jiang
Wentao Jiang
CLChuan Liu
Chuan Liu
RWRui Wang
Rui Wang
CYChen Yu
Chen Yu
To determine the hemostatic values of internal iliac artery balloon (IIABO) occlusion and abdominal aorta balloon occlusion (AABO), 142 patients with pernicious placenta previa were divided into three groups: control (45), IIABO (40), and AABO (57) groups, respectively. The blood loss, operative duration, time-averaged hemorrhage velocity (TAHV), blood transfusion, time-averaged transfusion velocity (TATV), and hospitalization days of these groups were compared. Angiographies and a circulatory simulation were used to unveil the bleeding mechanisms. Although the AABO group's operative duration and hospitalization days are longer (p < 0.001) than those of the other groups, the AABO group has considerably reduced blood loss (p < 0.05) and TAHV (p < 0.001) than the other groups. No obvious difference in blood transfusion and TATV between these groups can be observed. Angiographies showed that there was a large amount of blood flow in the pelvic cavity during IIABO, but AABO did not. In our modeling, the cumulative blood loss is about 2000 ml without using the balloon, which is the same as that when IIABO is used with collateral pressure of 75 mm Hg. The main source of blood loss is uterine arterioles. However, the blood loss during AABO is about 300 ml, which is mainly from uterine venules. These results suggested that IIABO failed to control bleeding, which may be related to collateral circulation, while AABO has a better prospect and may be more effective if the blood pressure of uterine venules is also isolated. These findings may guide technology selections for obstetricians and the improvement of hemostasis technology.

14 August 2025 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
JZJialu Zhang
Jialu Zhang
ZCZhaowei Chu
Zhaowei Chu
TBTaoping Bai
Taoping Bai
MZMing Zhang
Ming Zhang
WRWeiyan Ren
Weiyan Ren
WJWentao Jiang
Wentao Jiang
Purpose: While an expanded toe box (TB) design offers notable benefits for foot health in basketball players, its impact on movement performance remains insufficiently elucidated. This study aimed to explore this relationship and inform the development of advanced shoe designs.Methods: We conducted a controlled laboratory study with a within-subject crossover design. Thirty basketball players (25 males, five females; aged 18–20 years) performed standardized 5-m sprints, 180° lateral shuffling, and 45° sidestep cutting in six shoe versions. These versions systematically altered the toe allowance dividing line (TADL) (0, 1.5, 3 mm) and the sole center line (SCL) rotation (0°, 2°). Movement time, ground reaction forces, propulsion impulse, and joint kinematics were measured using optical timing systems, force platforms, and motion capture.Results: A 3-mm TADL extension significantly improved performance, reducing sprint, lateral shuffling, and sidestep cutting times by 6.53% (P < 0.01), 3.49% (P < 0.01), and 7.69% (P < 0.01), respectively, and increased propulsion impulse by 27.27% (P < 0.01). A 1.5-mm TADL extension improved sprint time by 4.02% (P < 0.05), though the effects on other movements were limited. A 2° SCL rotation showed no significant performance improvements (P > 0.05).Conclusion: Our findings suggest that shoes with enlarged TB improve both forward and lateral movements. Inward TADL extension optimizes performance by enhancing foot mobility and force transmission, while SCL rotation offers minimal benefits. These findings challenge the conventional tight-fitting shoe designs and provide insights for designing footwear that enhances agility and reduces injury risks.