Drew Thompson

Drew Thompson

Auto-generated profile, based on publicly available information

Drew Thompson

Centers for Disease Control and Prevention (CDC), National Institute for Occupational Safety and Health (NIOSH), Division of Field Studies and Engineering (DFSE) , 1090 Tusculum Ave, Cincinnati, OH 45226

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2018 in Building and Environment
Verified
Journal Article
Closed access
MTMin Tang
Min Tang
DTDrew Thompson
Drew Thompson
SCSheng-Chieh Chen
Sheng-Chieh Chen
YLYun Liang
Yun Liang
DPDavid Y.H. Pui
David Y.H. Pui

10 December 2024 in ACS Omega
Verified
Journal Article
Open access
KRKabir Rishi
Kabir Rishi
BKBon Ki Ku
Bon Ki Ku
CQChaolong Qi
Chaolong Qi
DTDrew Thompson
Drew Thompson
CWChen Wang
Chen Wang
PKPramod Kulkarni
Pramod Kulkarni
Inhalation exposure to respirable crystalline silica (RCS) during the fabrication of engineered stone-based kitchen countertops has been on the rise in recent years and has become a significant occupational health problem in the United States and globally. Little is known about the presence of nanocrystalline silica (NCS), i.e., particles below 100 nm. We present a methodology to quantify the crystalline silica content in the sub-100 nm size fraction of the aerosol released during engineered stone fabrication using X-ray diffraction (XRD) and Fourier transform infrared (FTIR) spectroscopy. Aerosol was generated in a test chamber designed per EN 1093-3 and sampled using cascade impactors. XRD and FTIR analysis showed the presence of both α-quartz (15-60%) and cristobalite (10-50%) polymorphs in all size fractions. With increasing particle size, the cristobalite content increased. Seventy percent of the total aerosol mass in the sub-100 nm fraction was found to be crystalline silica, qualitatively confirmed by electron diffraction and electron energy loss spectroscopy. The presence of other minerals was detected in all size fractions; no polymeric resin binder was detected in the sub-100 nm fraction. Although the sub-100 nm fraction was about 1% of the aerosol mass, it accounted for 4-24% of the aerosol surface area based on the total lung deposition. If the surface area is a more relevant exposure metric, the assessment of the efficacy of current engineering control systems using mass as an exposure metric may not provide adequate protection.

1 January 2009
Verified
Conference Paper
Closed access
PDF file
Iskander AkhatovIskander Akhatov
Iskander Akhatov
JHJustin M. Hoey
Justin M. Hoey
DTDrew Thompson
Drew Thompson
ALArtur Lutfurakhmanov
Artur Lutfurakhmanov
ZMZakaria Mahmud
Zakaria Mahmud
AOAlexander N. Osiptsov
Alexander N. Osiptsov
A combined theoretical/experimental study of micron size aerosol flows through micro-capillaries of diameter about 100 μm and length about 1 cm is presented. It is shown that under proper conditions at a relatively high velocity of about 100 m/s such an aerosol flow reveals a new manifestation of microfluidics: the Saffman force acting on aerosol particles in gas flowing through a micro-capillary becomes significant thereby causing noticeable migration of particles toward the center line of the capillary. This finding opens up new opportunities for aerosol focusing, which is in stark contrast to the classical aerodynamic focusing methodologies where only particle inertia and the Stokes force of gas-particle interaction are typically used to control particle trajectories. A mathematical model for aerosol flow through a micro-capillary accounting for complicated interactions between particles and carrier gas is presented. This model describes the experimental observables obtained via shadowgraphy for aerosol beams exiting micro-capillaries. It is further shown that it is possible to design a micro-capillary system capable of generating a Collimated Aerosol Beam (CAB) in which aerosol particles stay very close to a capillary center line. The performance of such a CAB system for direct-write fabrication on a substrate is demonstrated. The lines deposited by CAB for direct-write fabrication are shown to exhibit widths of less than 5 μm — superior to ink-jet. Materials deposition based upon directed aerosol flow has the potential of finding application in the fields of flexible electronics, sensors, and solar cells. In this paper, the genesis of a new materials deposition method termed Collimated Aerosol Beam Direct-Write (CAB-DW) is discussed.

23 August 2025 in Annals of Work Exposures and Health
Verified
Journal Article
Closed access
CWChen Wang
Chen Wang
KRKabir Rishi
Kabir Rishi
BKBon Ki Ku
Bon Ki Ku
PKPramod Kulkarni
Pramod Kulkarni
DTDrew Thompson
Drew Thompson
CQChaolong Qi
Chaolong Qi
This study investigated the compatibility of Tetrahydrofuran (THF) dissolution, following the procedures outlined in NIOSH Method 7500 and the similar OSHA ID-142 method, as a sample preparation technique for respirable crystalline silica (RCS) analysis in engineered stone materials compared to the muffle furnace (MF) ashing method. Our results revealed considerable variability in RCS content across different batches of engineered stone tested, underscoring the inherent material heterogeneity in engineered stone products. A statistically significant underestimation of RCS concentrations was observed when using THF dissolution for Stone A (polyester-based) samples collected on 47 mm polyvinyl chloride (PVC) filters, particularly at lower analyte loadings. In contrast, no statistically significant differences in RCS measurement were found between THF dissolution and MF ashing for the other 3 stone types, including one laboratory-synthetic material. The observed discrepancy in Stone A is likely attributed to the interaction of THF with its polyester resin binder, leading to swelling of the filter matrix and forming a non-volatile residue. This residue may physically entrap silica particles, hindering their complete recovery and subsequent quantification by X-ray diffraction (XRD). The suitability of THF processing as a sample preparation method is therefore highly dependent on the specific composition of the engineered stone. Based on these findings, MF ashing is recommended as the more reliable and universally applicable sample preparation method for engineered stone samples, especially those containing polyester resin binders. Caution should be exercised when considering THF dissolution for RCS analysis in engineered stones due to the potential for significant underestimation of actual RCS values, which could have implications for exposure assessments and regulatory compliance.