Diana Maritza Marulanda Cardona

Diana Maritza Marulanda Cardona

Auto-generated profile, based on publicly available information

Diana Maritza Marulanda Cardona

Universidad Militar Nueva Granada, Carrera 11 N° 101-80. Bogotá, Colombia

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2014 in Surface and Coatings Technology
Verified
Journal Article
Open access
FCF.E. Castillejo
F.E. Castillejo
DMD.M. Marulanda
D.M. Marulanda
JOJ.J. Olaya
J.J. Olaya
JAJ.E. Alfonso
J.E. Alfonso
Niobium carbide, chromium carbide and niobium–chromium carbide coatings were deposited using the thermo-reactive diffusion (TRD) deposition technique on AISI D2 steel substrates, and their wear and corrosion resistance was studied. The morphology of the coatings was characterized through optical and scanning electron microscopy (SEM), and the crystalline structure was studied through X-ray diffraction (XRD). Chemical composition was evaluated via energy-dispersive X-ray spectroscopy (EDS) and X-ray photoelectron spectroscopy (XPS). The hardness of the coatings was measured through nanoindentation, and their wear was studied using the ball on disk test. The electrochemical behavior was assessed with potentiodynamic polarization and electrochemical impedance (EIS) tests. The XRD results show the formation of the NbC for the niobium carbide coating, Cr23C6 and Cr7C3 for the chromium carbide coating, and NbC, Cr23C6 and Cr7C3 for the niobium–chromium coating. Hardness value for the niobium–chromium carbide coating was 27.62±2.56GPa, which was higher in comparison to 21.66±0.5GPa for niobium carbide, 14.7±1.1GPa for chromium carbide and 6.70±0.28GPa for the uncoated steel. The wear resistance obtained was higher for the niobium–chromium carbide coating. However, its corrosion resistance was lower than the corrosion resistance for binary coatings

1 October 2017 in Journal of Materials Research and Technology
Verified
Journal Article
Open access
DCDiana Maritza Marulanda Cardona
Diana Maritza Marulanda Cardona
JWJittraporn Wongsa-Ngam
Jittraporn Wongsa-Ngam
HJHernando Jimenez
Hernando Jimenez
TLTerence G. Langdon
Terence G. Langdon
Low-carbon steel AISI 1020 was subjected to high-pressure torsion (HPT) with 6.0Â GPa pressure through 1/4â5 turns. The microstructures of the samples in each turn were studied by means of X-ray diffraction (XRD) analyzing the changes in micro-strain, crystallite size and lattice parameter. Vickers testing was utilized to study the microhardness behavior of the samples subjected to HPT processing. The morphology evolution of the samples and especially the changes in ferrite and pearlite structures were studied for different numbers of turns using scanning electron microscopy (SEM). Keywords: 1020 steel, High pressure torsion, Hardnes

1 January 2011 in Thin Solid Films
Verified
Journal Article
Closed access
DMD.M. Marulanda
D.M. Marulanda
JOJ.J. Olaya
J.J. Olaya
UPU. Piratoba
U. Piratoba
AMA. Mariño
A. Mariño
ECE. Camps
E. Camps

1 December 2006 in Wear
Verified
Journal Article
Closed access
DADiego F. Arias
Diego F. Arias
DMDiana M. Marulanda
Diana M. Marulanda
ABAlejandra M. Baena
Alejandra M. Baena
ADAlfonso Devia
Alfonso Devia

1 October 2014 in Journal of Materials Research and Technology
Verified
Journal Article
Open access
DCDiana Maritza Marulanda Cardona
Diana Maritza Marulanda Cardona
JWJittraporn Wongsa-Ngam
Jittraporn Wongsa-Ngam
TLTerence G. Langdon
Terence G. Langdon
A low-carbon triple-alloyed steel was processed by high-pressure torsion at room temperature for up to 5 turns under a pressure of 6.0GPa. Microhardness, scanning electron microscopy and X-ray diffraction were used to investigate the hardness and microstructural evolution of the steel. Values of the Vickers microhardness were recorded across the sample diameters. The results show that there is a gradual evolution in both the hardness and the microstructure with increasing numbers of turns. However, the microhardness does not become fully homogeneous across the sample diameter after five turns and there remain significantly lower values in the center of the disk. These results indicate that complete homogeneity across the disks for this steel requires applied pressures higher than 6.0GPa and/or torsional straining through more than 5 turns

23 December 2012 in Journal of Elastomers & Plastics
Verified
Journal Article
Closed access
DMDiana Marulanda
Diana Marulanda
MPMarco Pérez
Marco Pérez
LCLuis Correa
Luis Correa
The aim of this article was to fabricate virgin polyvinyl chloride, polyethylene terephthalate, and low-density polyethylene blended with their corresponding recycled material in different ratios of virgin/recycled via injection molding and to evaluate their tensile strength, impact fracture, and hardness behavior. Raman spectroscopy was used to qualitatively study the characteristics of the recycled material in comparison with the virgin material. The impact testing method was the Charpy impact test, and for the hardness measurement, the shore D hardness method was used. The tensile tests were performed following the ATSM 683 standard. Scanning electron microscopy was used for chemical analysis and imaging to confirm the presence of contaminants.