Levent Saltık

Levent Saltık

Auto-generated profile, based on publicly available information

Levent Saltık

Cerrahpaşa Faculty of Medicine, Department of Pediatrics, Division of Pediatric Cardiology, İstanbul University-Cerrahpaşa, İstanbul, Turkey

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2008 in Cardiology in the Young
Verified
Journal Article
Closed access
PDF file
TDTevfik Demir
Tevfik Demir
FÖFunda Öztunç
Funda Öztunç
AEAyşe Güler Eroğlu
Ayşe Güler Eroğlu
LSLevent Saltık
Levent Saltık
GAGülay Ahunbay
Gülay Ahunbay
GAGürkan Altun
Gürkan Altun
Objective: Our aim was to investigate the change in diameter of holes within the oval fossa, and the role of aneurismal formation in reducing the size of the hole, in patients diagnosed during infancy with isolated defects in the floor of the fossa. Patients: In a retrospective study, we included 100 patients diagnosed during the first year of life with an isolated defect in the floor of the oval fossa who had subsequently been observed for at least 5 years. There were 56 females and 44 males. They had been admitted to hospital because of a murmur in 65, heart failure in 9, and other reasons in 17. The remaining 9 patients were referred from other institutions with an established diagnosis of defects within the oval fossa. Patients were grouped according to the size of the deficiency in the floor of the fossa. Defects of diameter less than 5 mm were considered to be small, and 20 patients had such defects. Medium sized defects were judged to be between 5 and 8 mm, with 26 patients fulfilling this criterion, with the other 54 patients having large defects with diameters greater than 8 mm. Results: The overall spontaneous rate of closure was 27%. Of those with medium defects, half closed spontaneously, but only 7.5% of those with large defects showed such closure. Of the patients who were diagnosed with heart failure, 9 had defects measuring 7 mm, and of these, 6 required surgical closure, 1 patient had spontaneous closure, while the defect became smaller in the remaining 2. On the other hand, in 9 out of 10 patients who had aneurysms, the diameter of the defect was between 7 and 15 mm. Amongst these patients, the defect closed spontaneously in 3, and reduced in size in the others. Conclusion: When holes within the oval fossa measure 8 mm or below, the majority of patients with experience either spontaneous closure or show decrease in size of the defect. In those with larger defects, the size usually increases, and surgery is needed for closure. If there is aneurismal formation, however, even when the defect measures more than 8 mm, the defect usually closes on its own or gets smaller.

1 December 2019 in Perinatal Journal
Verified
Journal Article
Open access
HEHakan Erenel
Hakan Erenel
MKMehmet Fatih Karslı
Mehmet Fatih Karslı
AOAysegul Ozel
Aysegul Ozel
SKSevim Özge Korkmaz
Sevim Özge Korkmaz
RAResul Arısoy
Resul Arısoy
CŞCihat Şen
Cihat Şen

1 March 2005 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Open access
PDF file
GÇGürkan Çetin
Gürkan Çetin
LSLevent Saltık
Levent Saltık
AÖAhmet Özkara
Ahmet Özkara
KBKadir Babaoğlu
Kadir Babaoğlu
Ischemic changes and acute or subacute cardiac failure after arterial switch operation generally results from imperfect transfer of coronary arteries to the neoaorta. Peroperative and early postoperative myocardial ischemia is the main cause of death in these patients. We present an unusual cause of myocardial ischemia and cardiac failure after arterial switch: a congenital coronary artery fistula between the circumflex artery and the right ventricle. The symptoms imitate coronary translocation failure. In differential diagnosis of the coronary perfusion problems encountered after the arterial switch operation, coronary artery fistula should not be forgotten, although it is rare.

6 January 2022 in Cardiology in the Young
Verified
Journal Article
Open access
PDF file
AEAyşe G. Eroğlu
Ayşe G. Eroğlu
SGSelman Gokalp
Selman Gokalp
SASezen UGAN ATİK
Sezen UGAN ATİK
DÖDamla Önal
Damla Önal
HAHazal C. Acar
Hazal C. Acar
LSLevent Saltık
Levent Saltık
Aim: The left and right ventricular dysfunction are important clinical course indicators in patients with repaired tetralogy of Fallot. This study aimed to evaluate ventricular volumes, functions, and myocardial deformation in children with repaired tetralogy of Fallot by real-time three-dimensional (four-dimensional) echocardiography and compared with healthy children. It also aimed to investigate the relationships between ventricular volumes, functions, and myocardial deformation parameters in the patients. Materials and methods: In this cross-sectional study, 35 patients (mean age 15.1 ± 2.8 years, 54% male) and 35 healthy controls of similar age, gender, and body measurements underwent echocardiography. End-diastolic volume index, end-systolic volume index, and ejection fractions of both ventricles; global longitudinal, circumferential, radial strain, twist, and torsion of the left ventricle; the longitudinal strain of the right ventricle free wall and septum were measured. Results: Left ventricular ejection fraction, global circumferential and radial strain, twist and torsion were significantly lower in patients compared with controls. Left ventricular ejection fraction correlated with global circumferential (r = −0.446, p < 0.001) and radial strain (r = −0.433, p < 0.001) in the patients. Right ventricular volumes were significantly higher, and ejection fraction was significantly lower in patients compared with controls. All right ventricular parameters correlated with each other in the patients. Conclusion: Left ventricular contraction pattern was changed, circumferential and radial fibres were most affected in the patients. Right ventricular dilatation and dysfunction were detected, and right ventricular ejection fraction correlated well with strain measurements of the right ventricle.