Errors in voltage and current transformer and compensation algorithms may cause errors in local voltage and current phase angle measured by phasor measurement units (PMU), whose difference is defined as the power factor angle (PFA). Consequently, the error of local PMU voltage and current phase angle difference, i.e., power factor angle deviation (PFAD), can cause reactive power measurement deviation, which leads to reactive power measurement inconsistency of symmetrical double-circuit lines, deteriorating the application of dynamic monitoring. In this paper, a three-step correction method for PFAD of double-circuit lines is proposed based on the operation characteristics and reactive power of double-circuit lines:1) estimate the difference between PFADs of different lines at the same end; 2) estimate the difference of PFADs at both ends of one line of the double-circuit lines; 3) estimate the local PFAD. The method does not require line parameters and can realize the correction of PFAD at each end of the double circuit line. Finally, the effectiveness and robustness of the proposed method are demonstrated by the simulation results using both simulated and field data.

20 November 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JYJinzhou Yang
Jinzhou Yang
LGLei Gu
Lei Gu
XZXiang Zheng
Xiang Zheng
YYYiting Yu
Yiting Yu
HKHe Kong
He Kong
AXAncheng XUE
Ancheng XUE
The phasor measurement units (PMUs) are the eyes for the dynamic of the power system. However, the measured phase angle data from PMUs for a transmission line (TL) may coexist with different deviations, i.e., the deviations in voltage/current phase angle difference (DVPAD/DCPAD) between different ends of the TL, and the deviations in power factor angle (DPFA, i.e., the deviations in phase angle difference between voltage and current at the same end), which threaten the advanced application with PMUs. This article proposes a correction method for the phase angle data when the DVPAD/DCPAD and DPFA coexist for the TL with unknown line parameters. Specifically, first, the abnormal voltage phase angle differences and power factor angle anomalies are discussed, and the corresponding illustrative examples are presented. Second, the mathematical model for estimating phase angle deviations in a general case is presented. Third, a “two-step” method to correct the phase angle data of PMU for the TLs with unknown parameters is proposed, in which the DVPAD/DCPAD between two ends is estimated in advance, and then, the DPFA is estimated. Finally, simulation and examples with field data verify the feasibility and engineering applicability of the proposed method.