Mart G. F. Last

Mart G. F. Last

Auto-generated profile, based on publicly available information

Mart G. F. Last

Department of Cell and Chemical Biology, Leiden University Medical Center, Leiden, The Netherlands

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 April 2019 in Nature Communications
Verified
Journal Article
Open access
PDF file
SDSiddharth Deshpande
Siddharth Deshpande
FBFrank Brandenburg
Frank Brandenburg
ALAnson Lau
Anson Lau
MLMart G. F. Last
Mart G. F. Last
WSWillem Kasper Spoelstra
Willem Kasper Spoelstra
CDCees Dekker
Cees Dekker
Liquid-liquid phase separation (LLPS), especially coacervation, plays a crucial role in cell biology, as it forms numerous membraneless organelles in cells. Coacervates play an indispensable role in regulating intracellular biochemistry, and their dysfunction is associated with several diseases. Understanding of the LLPS dynamics would greatly benefit from controlled in vitro assays that mimic cells. Here, we use a microfluidics-based methodology to form coacervates inside cell-sized (~10 µm) liposomes, allowing control over the dynamics. Protein-pore-mediated permeation of small molecules into liposomes triggers LLPS passively or via active mechanisms like enzymatic polymerization of nucleic acids. We demonstrate sequestration of proteins (FtsZ) and supramolecular assemblies (lipid vesicles), as well as the possibility to host metabolic reactions (β-galactosidase activity) inside coacervates. This coacervate-in-liposome platform provides a versatile tool to understand intracellular phase behavior, and these hybrid systems will allow engineering complex pathways to reconstitute cellular functions and facilitate bottom-up creation of synthetic cells.

2 April 2020 in ACS Nano
Verified
Journal Article
Open access
MLMart G. F. Last
Mart G. F. Last
SDSiddharth Deshpande
Siddharth Deshpande
CDCees Dekker
Cees Dekker
Membraneless organelles formed by liquid-liquid phase separation are dynamic structures that are employed by cells to spatiotemporally regulate their interior. Indeed, complex coacervation-based phase separation is involved in a multitude of biological tasks ranging from photosynthesis to cell division to chromatin organisation, and more. Here, we use an on-chip microfluidic method to control and study the formation of membraneless organelles within liposomes, using pH as the main control parameter. We show that a transmembrane proton flux that is created by a stepwise change in the external pH can readily bring about the coacervation of encapsulated components in a controlled manner. We employ this strategy to induce and study electrostatic as well as hydrophobic interactions between the coacervate and the lipid membrane. Electrostatic interactions using charged lipids efficiently recruit coacervates to the membrane and restrict their movement along the inner leaflet. Hydrophobic interactions via cholesterol-tagged RNA molecules provide even stronger interactions, causing coacervates to wet the membrane and affect the local lipid-membrane structure, reminiscent of coacervate-membrane interactions in cells. The presented technique of pH-triggered coacervation within cell-sized liposomes may find applications in synthetic cells and in studying biologically relevant phase separation reactions in a bottom-up manner.

28 October 2022 in eLife
Verified
Journal Article
Open access
DBDaan B Boltje
Daan B Boltje
JHJacob Hoogenboom
Jacob Hoogenboom
AJArjen J Jakobi
Arjen J Jakobi
GJGrant Jensen
Grant Jensen
CJCaspar Th Jonker
Caspar Th Jonker
SHSander Den Hoedt
Sander Den Hoedt
Cryogenic electron tomography (cryo-ET) combined with subtomogram averaging, allows in situ visualization and structure determination of macromolecular complexes at subnanometre resolution. Cryogenic focused ion beam (cryo-FIB) micromachining is used to prepare a thin lamella-shaped sample out of a frozen-hydrated cell for cryo-ET imaging, but standard cryo-FIB fabrication is blind to the precise location of the structure or proteins of interest. Fluorescence-guided focused ion beam (FIB) milling at target locations requires multiple sample transfers prone to contamination, and relocation and registration accuracy is often insufficient for 3D targeting. Here, we present in situ fluorescence microscopy-guided FIB fabrication of a frozen-hydrated lamella to address this problem: we built a coincident three-beam cryogenic correlative microscope by retrofitting a compact cryogenic microcooler, custom positioning stage, and an inverted widefield fluorescence microscope (FM) on an existing FIB scanning electron microscope. We show FM controlled targeting at every milling step in the lamella fabrication process, validated with transmission electron microscope tomogram reconstructions of the target regions. The ability to check the lamella during and after the milling process results in a higher success rate in the fabrication process and will increase the throughput of fabrication for lamellae suitable for high-resolution imaging.

18 August 2023 in Nature Methods
Verified
Journal Article
Closed access
PDF file
MLMart G. F. Last
Mart G. F. Last
LVLenard M. Voortman
Lenard M. Voortman
TSThomas H. Sharp
Thomas H. Sharp

18 January 2025 in bioRxiv
Verified
Preprint
Open access
PDF file
MLMart G. F. Last
Mart G. F. Last
LVLenard M. Voortman
Lenard M. Voortman
TSThomas H. Sharp
Thomas H. Sharp
Automation and improved hardware have greatly accelerated the rate of data generation in cryoET. As the field moves towards quantitative cryoET , the scale of the resulting datasets presents a significant challenge for analysis and interpretation. To explore ways of handling datasets comprising thousands of tomograms, we investigated a comprehensive segmentation strategy – assigning an ontology-based identity to every voxel in a dataset – that is based on the sequential application of multiple convolutional neural networks. Using an openly available dataset of over 1800 Chlamydomonas reinhardtii tomograms as a test case, we demonstrate the segmentation of 25 different subcellular features across the full dataset, while requiring only a few seconds of processing time per tomogram. We show how the approach enables the representation of large datasets as searchable databases and propose the usage of ontology-based segmentations for improving two common processing tasks in cryoET. First, we explore context-aware particle picking as a method to retain biological context when selecting particles for subtomogram averaging and other downstream analyses. Secondly, we demonstrate area-selective template matching , where we use segmentation-based masks to avoid redundant computations in template matching and enable >500-fold faster processing in specific cases. To illustrate the utility of the approach, all segmentation results have also been made available online via cryopom.streamlit.app .

20 December 2024 in eLife
Verified
Journal Article
Open access
MLMart Gf Last
Mart Gf Last
LALeoni Abendstein
Leoni Abendstein
LVLenard M Voortman
Lenard M Voortman
TSThomas H Sharp
Thomas H Sharp
Segmentation is a critical data processing step in many applications of cryo-electron tomography. Downstream analyses, such as subtomogram averaging, are often based on segmentation results, and are thus critically dependent on the availability of open-source software for accurate as well as high-throughput tomogram segmentation. There is a need for more user-friendly, flexible, and comprehensive segmentation software that offers an insightful overview of all steps involved in preparing automated segmentations. Here, we present Ais: a dedicated tomogram segmentation package that is geared towards both high performance and accessibility, available on GitHub. In this report, we demonstrate two common processing steps that can be greatly accelerated with Ais: particle picking for subtomogram averaging, and generating many-feature segmentations of cellular architecture based on in situ tomography data. Featuring comprehensive annotation, segmentation, and rendering functionality, as well as an open repository for trained models at aiscryoet.org, we hope that Ais will help accelerate research and dissemination of data involving cryoET.