Inés Nieto Carvajal

Inés Nieto Carvajal

Auto-generated profile, based on publicly available information

Inés Nieto Carvajal

Campus de Espinardo Instituto Universitario de Investigación en Óptica y Nanofísica Universidad de Murcia E-30100 Murcia Spain

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2012 in Discover Nano
Verified
Journal Article
Open access
PDF file
JMJuan Francisco Gonzalez Martinez
Juan Francisco Gonzalez Martinez
INInés Nieto-Carvajal
Inés Nieto-Carvajal
JAJosé Abad
José Abad
JCJaime Colchero
Jaime Colchero
In this study, we show that the correct determination of surface morphology using scanning force microscopy (SFM) imaging and power spectral density (PSD) analysis of the surface roughness is an extremely demanding task that is easily affected by experimental parameters such as scan speed and feedback parameters. We present examples were the measured topography data is significantly influenced by the feedback response of the SFM system and the PSD curves calculated from this experimental data do not correspond to that of the true topography. Instead, either features are "lost" due to low pass filtering or features are "created" due to oscillation of the feedback loop. In order to overcome these serious problems we show that the interaction signal (error signal) can be used not only to quantitatively control but also to significantly improve the quality of the topography raw data used for the PSD analysis. In particular, the calibrated error signal image can be used in combination with the topography image in order to obtain a correct representation of surface morphology ("true" topographic image). From this "true" topographic image a faithful determination of the PSD of surface morphology is possible. The corresponding PSD curve is not affected by the fine-tuning of feedback parameters, and allows for much faster image acquisition speeds without loss of information in the PSD curve.

12 October 2012 in arXiv
Verified
Preprint
Open access
PDF file
JMJuan Francisco Gonzalez Martinez
Juan Francisco Gonzalez Martinez
ICInés Nieto Carvajal
Inés Nieto Carvajal
JCJaime Colchero
Jaime Colchero
A method to precisely calibrate the oscillation amplitude in Dynamic Scanning Force Microscopy is described. It is experimentally shown that a typical electronics used to process the dynamic motion of the cantilever can be adjusted to transfer the thermal noise of the cantilever motion from its resonance frequency to a much lower frequency within the typical bandwidth of the corresponding electronics. Therefore, the thermal noise measured in the in-phase ("phase") and out of phase ("amplitude") output of such an electronics can be related to the thermal energy $kT$. If the force constant of the cantilever is known then the oscillation amplitude can be precisely calibrated from the thermal power measured in these signals. Based on this concept, two procedures for the calibration of the oscillation amplitude are proposed. One is based on simple calculation of the Root Mean Square (RMS) measured at the outputs of the electronics used to process the dynamic motion of the cantilever, and the other one is based on analysis of the corresponding spectrum and the calculation of the quality factor, the resonance frequency and the signal strength.