Nan Ma

Nan Ma

Auto-generated profile, based on publicly available information

Nan Ma

Shenzhen Power Supply Co., Ltd., Shenzhen 518020, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 December 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
YWYijun Wang
Yijun Wang
PGPeiqian Guo
Peiqian Guo
NMNan Ma
Nan Ma
GLGuowei Liu
Guowei Liu
A precise short-term load-forecasting model is vital for energy companies to create accurate supply plans to reduce carbon dioxide production, causing our lives to be more environmentally friendly. A variety of high-voltage-level load-forecasting approaches, such as linear regression (LR), autoregressive integrated moving average (ARIMA), and artificial neural network (ANN) models, have been proposed in recent decades. However, unlike load forecasting in high-voltage transmission systems, load forecasting at the distribution network level is more challenging since distribution networks are more variable and nonstationary. Moreover, existing load-forecasting models only consider the features of the time domain, while the demand load is highly correlated to the frequency-domain information. This paper introduces a robust wavelet transform neural network load-forecasting model. The proposed model utilizes both time- and frequency-domain information to improve the model’s prediction accuracy. Firstly, three wavelet transform methods, variational mode decomposition (VMD), empirical mode decomposition (EMD), and empirical wavelet transformation (EWT), were introduced to transform the time-domain demand load data into frequency-domain data. Then, neural network models were trained to predict all components simultaneously. Finally, all the predicted data were aggregated to form the predicted demand load. Three cases were simulated in the case study stage to evaluate the prediction accuracy under different layer numbers, weather information, and neural network types. The simulation results showed that the proposed robust time–frequency load-forecasting model performed better than the traditional time-domain forecasting models based on the comparison of the performance metrics, including the mean absolute error (MAE), mean absolute percentage error (MAPE), and root mean squared error (RMSE).

1 March 2024 in Energies
Verified
Journal Article
Open access
PDF file
NMNan Ma
Nan Ma
ZXZiwen Xu
Ziwen Xu
YWYijun Wang
Yijun Wang
GLGuowei Liu
Guowei Liu
LXLisheng Xin
Lisheng Xin
CCChen Chen
Chen Chen
Coastal cities often face typhoons and urban water logs, which can cause power outages and significant economic losses. Therefore, it is necessary to study the impact of these disasters on urban distribution networks and improve their flexibility. This paper presents a method for predicting power-grid failure rates in typhoons and water logs and suggests a strategy for improving network elasticity after the disaster. It is crucial for the operation and maintenance of power distribution systems during typhoon and water-logging disasters. By mapping the wind speed and water depth at the corresponding positions in the evolution of wind and water logging disasters to the vulnerability curve, the failure probability of the corresponding nodes is obtained, the fault scenario is generated randomly, and the proposed dynamic reconstruction method, which can react in real-time to the damage the distribution system received, has been tested on a modified 33-node and a 118-node distribution network, with 3 and 11 distribution generators loaded, respectively. The results proved that this method can effectively improve the resiliency of the distribution network after a disaster compared with the traditional static reconstruction method, especially in the case of long-lasting wind and flood disasters that have complex and significant impacts on the distribution system, with about 26% load supply for the 33-node system and nearly 95% for the 118-node system.

1 December 2022 in Energies
Verified
Journal Article
Open access
PDF file
YWYijun Wang
Yijun Wang
Yizhen WangYizhen Wang
Yizhen Wang
NMNan Ma
Nan Ma
RZRui Zeng
Rui Zeng
ZWZhiqian Wang
Zhiqian Wang
The modular multilevel converter (MMC) has become a very promising technology for long-distance and large-capacity transmission of offshore wind power. However, both sides of the AC transmission line at the sending end are controllable electronic power devices, resulting in difficulty in fault identification and inapplicability of traditional differential protection schemes. In order to solve this problem, a wave-similarity-based protection scheme is proposed for AC transmission line faults. Firstly, the symmetrical and asymmetrical fault current characteristics of the double-fed induction generator (DFIG) and MMC are studied, indicating that the fault current characteristics are obviously different from the synchronous units. Secondly, the wave-similarity-based protection scheme is proposed based on the different wave forms of the fault currents of the MMC and DFIG. When the similarity coefficient is less than the margin coefficient, there is a fault in this phase. Moreover, the proposed wave-similarity-based protection scheme can identify all types of short-circuit faults correctly and is not affected by the transition resistance. Finally, simulations of an MMC-HVDC system with offshore wind farms are conducted to validate the effectiveness and correctness of the proposed protection scheme.

4 April 2024 in Energies
Verified
Journal Article
Open access
PDF file
YWYijun Wang
Yijun Wang
JSJiaju Shi
Jiaju Shi
NMNan Ma
Nan Ma
GLGuowei Liu
Guowei Liu
LXLisheng Xin
Lisheng Xin
CCChen Chen
Chen Chen
In order to achieve the flexible and efficient utilization of distributed energy resources, microgrids (MGs) can enhance the self-healing capability of distribution systems. Conventional primary droop control in microgrids exhibits deviations in voltage and frequency and lacks research on voltage–frequency control during network reconfiguration. Therefore, this paper investigates the control strategy of secondary control for voltage and frequency during the process of reconstructing distribution networks to operate in the form of microgrids after faults. Firstly, the mathematical model of three-phase voltage-source inverters with droop control is analyzed. Then, inspired by the generator’s secondary frequency control strategy, an improved secondary control method based on droop control is proposed, and the effectiveness of the improved droop control strategy is verified. Finally, simulation examples of distribution networks with various dynamic boundary topology changes are designed to simulate a relatively stable control result, validating the proposed strategy.