1 May 2022 in Annals of Laboratory Medicine
Eunbin Chong, M.D., Hui-Jin Yu, M.D., Tae Yeul Kim, M.D., Keon Hee Yoo, M.D., Ph.D., Yae-Jean Kim, M.D., Ph.D., Hee Jae Huh, M.D., Ph.D., and Nam Yong Lee, M.D., Ph.D.. Ann Lab Med 2022;42:370-2. https://doi.org/10.3343/alm.2022.42.3.370
12 December 2023 in Microbiology Spectrum
In October 2022, we experienced a significant increase in samples showing high galactomannan (GM) indexes ranging from 6.22 to 10.58, as determined by the Platelia Aspergillus antigen immunoassay, also known as the GM test. After reviewing the medical records of nine GM antigenemia cases that did not show evidence of invasive aspergillosis, we found that these patients had received total parenteral nutrition (TPN) products from the same manufacturer, whose supplier of the glucose component had recently changed. The TPN products supplied by the specific manufacturer in October were subjected to a GM assay. The glucose component of the products from three different lot numbers exhibited strong positive results in the GM assay. Microbiological investigations through fungal culture and PCR on the TPN products were negative. The present study demonstrated that the glucose component of the TPN products contained a high level of GM antigen, which caused false-positive GM test results. The source of GM in the glucose component was glucoamylase, which was produced from Aspergillus niger to obtain glucose monohydrate from starch. Investigation of three commercially available glucoamylase products exhibited positive GM and 1,3-β-D-glucan tests with various titers positive up to 1:1,000 dilutions, while fungal cultures were all negative. Quality assurance measures of TPN products to prevent GM contamination should be emphasized during the manufacturing process to avoid unnecessary additional diagnostic procedures and overtreatment of invasive aspergillosis due to false-positive GM tests. IMPORTANCE: This manuscript describes an occurrence of false-positive GM tests in patients receiving TPN products from a manufacturer who had recently changed the supplier of the glucose component. We describe the clinical presentation of nine false-positive cases and the results of serologic and microbiological investigations of the TPN products suspected of contamination with GM. Attempts to detect GM in parenteral nutrition products were made since the detection of GM in sodium gluconate-containing solutions in 2007, but none of them identified the source of elevated GM indexes in TPN products. However, the present study demonstrated that the glucose component of the TPN products contained a high level of GM antigen, which caused false-positive GM assay results. The source of GM was glucoamylase, which was derived from A. niger in the manufacturing process. Physicians and clinical microbiology laboratories should be aware of this issue to improve interpretation and patient care.
6 August 2023 in Diagnostic Microbiology and Infectious Disease
1 April 2026 in Drug Design, Development and Therapy
The increasing prevalence of neuropsychiatric medication misuse highlights the critical need for efficient drug screening in clinical laboratories. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) application for broad serum drug screening remains limited in many clinical settings. Serum analysis is particularly valuable for identifying current drug exposure, confirming the cause of intoxication, and monitoring patient medication adherence. This study aimed to develop and validate an LC-MS/MS method using multiple reaction monitoring followed by information-dependent acquisition-triggered enhanced product ion scans for the simultaneous qualitative identification of 77 neuropsychiatric drugs, and to present its large-scale clinical application over three years. Validation included precision, accuracy, recovery, matrix effects, selectivity, and interference. A minimal serum volume (20 μL) underwent simple protein precipitation, with preparation time under 15 minutes per batch. This method was applied to 1,021 clinical serum specimens. Chromatographic separation was completed in 15 minutes. The precisions (CV) for calculated concentrations and retention times were < 30% and < 1.5%, respectively. Accuracy was assessed for 60 of the 77 analytes (100% agreement). Mean recovery and matrix effects were 93.1% and 99.9%, respectively. Most test orders originated from psychiatry and neurology outpatients. Although fewer orders came from the Department of Emergency Medicine (EM), the EM patients exhibited a higher positivity rate. The most frequently detected drug classes were benzodiazepines (37.9%), antidepressants (30.7%), and antipsychotics (19.7%). Common specific analytes included clonazepam/7-aminoclonazepam (10.2%) and lorazepam (10.0%). We developed and validated a LC-MS/MS method for the simultaneous detection of a wide range of neuropsychiatric drugs. The method proved essential for verifying medication history, identifying non-adherence, and diagnosing acute intoxication. Our findings highlight the critical role of broad-spectrum serum screening in managing medication-related emergencies and optimizing long-term therapeutic care.