1 January 2022 in Trends in Hearing
When listening with a cochlear implant through one ear and acoustically through the other, binaural benefits and spatial hearing abilities are generally poorer than in other bilaterally stimulated configurations. With the working hypothesis that binaural neurons require interaurally matched inputs, we review causes for mismatch, their perceptual consequences, and experimental methods for mismatch measurements. The focus is on the three primary interaural dimensions of latency, frequency, and level. Often, the mismatch is not constant, but rather highly stimulus-dependent. We report on mismatch compensation strategies, taking into consideration the specific needs of the respective patient groups. Practical challenges typically faced by audiologists in the proposed fitting procedure are discussed. While improvement in certain areas (e.g., speaker localization) is definitely achievable, a more comprehensive mismatch compensation is a very ambitious endeavor. Even in the hypothetical ideal fitting case, performance is not expected to exceed that of a good bilateral cochlear implant user.
1 February 2018 in Journal of Neuroscience Methods
14 January 2020 in Ear & Hearing
Objectives: The human auditory nerve can be electrically stimulated by cochlear implants (CIs) with pulse trains consisting of biphasic pulses with small interphase gaps (IPGs). In animal experiments, lower electrically evoked compound action potential (ECAP) thresholds in implanted animals were found for increasing IPGs (2.1, 10, 20, 30 μs). ECAP thresholds may correlate with loudness thresholds. Therefore, in this study, the IPG effect on loudness and dynamic range was investigated in nine CI subjects. Design: A loudness-matching procedure was designed with three different IPGs (2.1, 10, 30 μs) at three different pulse rates (200, 600, 1000 pps). An adaptive loudness-balancing test was performed at the 50% stimulus amplitude level of the dynamic range and most comfortable loudness level (MCL). Results: Increasing the IPG or increasing the pulse rate led to a significant decrease in stimulus amplitude for 50% level and MCL in the adaptive test. Because the stimulus amplitudes for 50% level and MCL decreased in a different manner, the calculated upper dynamic range between MCL and 50% level significantly decreased for increasing IPG between 0.24 and 0.38 dB. This decrease in the upper dynamic range was observed for all pulse rates. Conclusions: It is possible to reduce the stimulus amplitude level for the same loudness impression using larger IPGs in CIs; however, larger IPGs decrease the dynamic range. These findings could help during the fitting process of CIs to find the balance between saving battery and a proper dynamic range.
25 August 2019 in Cochlear Implants International
The rate pitch discrimination ability of cochlear implant (CI) users is poor compared to normal-hearing (NH) listeners. At low pulse rates, the just noticeable difference (JND) is on average 20% of the base rate, while NH listeners can discriminate small frequency differences of 0.2% at 1 kHz. Recent investigations suggest that double pulses with short interpulse intervals (IPIs) may have a beneficial effect on rate pitch discrimination in CI users. In a first experiment psychophysical tests were carried out to establish whether rate pitch in CI users could be improved by applying double pulses with equal amplitude and short IPIs. Pulse trains with base rates of 200 and 400 pps, composed of either single pulses or double pulses with IPIs of 15, 50, and 150 μs were presented. In a second experiment pairwise comparisons were carried out between pitch of a pulse train composed of alternating double and single pulses with pitch of pulse trains composed of single pulses. The alternating pulse train had a base rate of 400 pps, the pulse trains with solely single pulses had base rates of 200, 300, and 400 pps. The loudness and pitch perception of the different stimulus types were evaluated and compared. A significant loudness difference was found between single and double pulses for both pulse rates. The JND for pitch discrimination between double-pulse IPIs had a high inter-subject variability, and no significant group effect was found. No subject reported a pitch change between double pulse and single pulse stimulation. In contrast, most of the subjects recognized a change in pitch between single-pulse trains and pulse trains with alternating double and single pulses. The latter was lower in pitch than the single-pulse train stimulation. To conclude, using (equal amplitude) double pulses instead of single pulses in a pulse train does not effect pitch perception. Instead, loudness differs between double pulses and single pulses with the same amplitude.
8 December 2020 in medRxiv
Modern cochlear implants employ charge-balanced biphasic and triphasic pulses. However, the effectiveness of electrical pulse shape and polarity is still a matter of debate. For this purpose, in a previous study (Bahmer & Baumann, 2013) electrophysiological and psychophysical measurement after triphasic pulse stimulation with cathodic second phase was determined. Depending on the pulse shape configuration, the stimulation effectiveness differed similarly for electrophysiological and psychophysical measurements. However, the experiments were limited to stimulation pulses with cathodic second phase. In this study, cathodic and anodic second phase stimulation was applied. Evoked compound action potentials (ECAPs) and psychophysical responses were recorded in eleven cochlear implant recipients (SYNCHRONY/SONATAti100/PULSARci100 devices, MED-EL Innsbruck). We compared the strength of the ECAP responses with individual psychophysical threshold levels depending on the pulse shape. Results for pulses with cathodic second phase showed the weakest ECAP response and highest psychophysical thresholds for symmetric triphasic pulse shapes, and the strongest ECAP response and lowest psychophysical thresholds for biphasic pulses. The ECAP responses for anodic second phase differed from the results of triphasic stimulation with cathodic second phase. The U-shape of the ECAP response with increasing phase amplitude ratio (PAR) for cathodic second phase could not be observed for the anodic second phase. Instead, a flat curve was observed. In contrast, psychophysical threshold curves with increasing PAR were similar between cathodic and anodic second phase stimulation.