28 April 2018 in World Journal of Gastroenterology
FMFabio Ramalho Tavares Marinho
Fabio Ramalho Tavares Marinho
+2
Papillary fistulotomy vs conventional cannulation for endoscopic biliary access: A prospective randomized trial
1 December 2016 in Journal of Medical Case Reports
When encountering solid pancreatic lesions, nonpancreatic primary metastases are rare and differentiating a metastasis from a primary neoplastic lesion is challenging. The clinical presentation and radiologic features can be similar and the possibility of a pancreatic metastasis should be considered when the patient refers to a history of a different primary cancer. Endoscopic ultrasound offers a key anatomical advantage in accessing the pancreas and endoscopic ultrasound-guided fine-needle aspiration has become the gold standard method for diagnosing pancreatic lesions. A 58-year-old white Hispanic woman with a history of uveal malignant melanoma, presented with abdominal pain and jaundice. On admission, laboratory tests were performed (her total bilirubin was 6.37 mg/dL with a direct fraction of 5.30 mg/dL). Cross-sectional, abdominal computed tomography with contrast, showed a low-attenuating lesion localized in the pancreatic head (measuring 4 × 3 cm) and a thinner section of the distal bile duct suspicious for compression. Our patient was scheduled for an endoscopic ultrasound-guided fine-needle aspiration to establish a diagnosis. Endoscopic ultrasound showed a solid, hypoechoic, well-defined lesion with regular contours (measuring 3.17 × 2.61 cm), localized between the head and neck of the pancreas. Endoscopic ultrasound-guided fine-needle aspiration was performed with a 22G needle and cytology confirmed the diagnosis of metastatic melanoma. Our patient subsequently underwent right orbital exenteration, followed by duodenopancreatectomy without complications. At the moment our patient is receiving adjuvant chemotherapy at an outside oncology clinic. To the best of our knowledge, this is a very rare presentation of an ocular malignant melanoma with an isolated pancreatic metastasis causing symptomatic biliary obstruction. Endoscopic ultrasound-guided fine-needle aspiration has proven to be the best method to diagnose solid pancreatic lesions. In this particular case, cytology was essential in confirming the diagnosis and guiding the most adequate therapy, which was a pancreatic resection, ocular exenteration of the melanoma, followed by adjuvant chemotherapy.
7 July 2023 in American Journal of Gastroenterology
VBVitor Ottoboni Brunaldi
PGPedro Victor Aniz Gomes
EMEduardo Guimarães Hourneaux de Moura
Eduardo Guimarães Hourneaux de Moura
+10
INTRODUCTION: Adverse events (AE) after endoscopic retrograde cholangiopancreatography (ERCP) are not uncommon and post-ERCP acute pancreatitis (PEP) is the most important one. Thermal injury from biliary sphincterotomy may play an important role and trigger PEP or bleeding. Therefore, this study evaluated the outcomes of 2 electric current modes used during biliary sphincterotomy. METHODS: From October 2019 to August 2021, consecutive patients with native papilla undergoing ERCP with biliary sphincterotomy were randomized to either the pure cut or endocut after cannulation. The primary outcome was PEP incidence. Secondary outcomes included intraprocedural and delayed bleeding, infection, and perforation. RESULTS: A total of 550 patients were randomized (272 pure cut and 278 endocut). The overall PEP rate was 4.0% and significantly higher in the endocut group (5.8% vs 2.2%, P = 0.034). Univariate analysis revealed >5 attempts (P = 0.004) and endocut mode (P = 0.034) as risk factors for PEP. Multivariate analysis revealed >5 attempts (P = 0.005) and a trend for endocut mode as risk factors for PEP (P = 0.052). Intraprocedural bleeding occurred more often with pure cut (P = 0.018), but all cases were controlled endoscopically during the ERCP. Delayed bleeding was more frequent with endocut (P = 0.047). There was no difference in perforation (P = 1.0) or infection (P = 0.4999) between the groups. DISCUSSION: Endocut mode may increase thermal injury leading to higher rates of PEP and delayed bleeding, whereas pure cut is associated with increased intraprocedural bleeding without clinical repercussion. The electric current mode is not related to perforation or infection. Further RCT assessing the impact of electric current on AE with overlapping preventive measures such as rectal nonsteroidal anti-inflammatory drugs and hyperhydration are needed. The study was submitted to the Brazilian Clinical Trials Platform (http://www.ensaiosclinicos.gov.br) under the registry number RBR-5d27tn.
1 March 2016 in Gastrointestinal Endoscopy
22 November 2021 in Diseases of the Colon & Rectum
GOGuilherme H. P. de Oliveira
Guilherme H. P. de Oliveira
GSGustavo L.R. M.Sc. Silva
MMMauricio K M.Sc. Minata
+1
BACKGROUND: Curvilinear array ultrasound transducers enable tissue sampling and have therapeutic capabilities. Nevertheless, colonic intubation and maneuvering with these transducers is technically challenging and is therefore typically limited to the rectosigmoid area. This retrospective cohort study aimed to evaluate the safety, feasibility, and diagnostic yield of colonoscopic ultrasound-guided fine-needle aspiration in deep colonic intubation. IMPACT OF INNOVATION: The impact of this innovation is to enable tissue sampling of colonic and extracolonic lesions guided by endoscopic ultrasound. TECHNOLOGY, MATERIALS, AND METHODS: Curvilinear array ultrasound is used in the evaluation of luminal and extraluminal colonic diseases. Thirteen patients underwent colonoscopic ultrasound with a curvilinear array ultrasound endoscope in a single center for subepithelial lesions, cancer staging, and extracolonic lesions from July 2015 to February 2021. Endosonography was performed using an Olympus EU-ME1 and GF-UCT 180 with a 5-12MHz curvilinear array transducer. The primary outcome was the percentage of patients who were successfully scanned with the endoscopic ultrasound. The secondary outcomes included the success rate of fine-needle aspiration, the diagnostic yield of the tissue samples, and the adverse events related to the procedure. PRELIMINARY RESULTS: A total of 13 female patients underwent colonoscopic ultrasound. All patients (100%, 13/13) were successfully scanned. Fine-needle aspiration was deemed necessary and successfully performed in 100% (5/5) of the patients. Tissue samples collected by fine-needle aspiration resulted in a diagnostic yield of 60%, and no adverse events resulted from this intervention. CONCLUSIONS: This study demonstrates the feasibility of performing colonoscopic ultrasound with a curvilinear array transducer. Fine-needle aspiration for subepithelial, colonic, and extracolonic lesions is feasible and safe in this setting with no adverse events reported in our study. FUTURE DIRECTIONS: Future research should be directed toward validating colonoscopic ultrasound with a curvilinear array transducer technique in prospective randomized trials. Studies evaluating the feasibility and safety of endoscopic ultrasound-guided interventions in the colon, such as abscess drainage and enteral anastomosis, should be considered.