Ji Li

Ji Li

Auto-generated profile, based on publicly available information

Ji Li

Laboratory for Space Environment and Physical Sciences and the Department of Electrical Engineering, Harbin Institute of Technology, Harbin 150001, China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 May 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
DPDonghua Pan
Donghua Pan
JLJi Li
Ji Li
CJChongyu Jin
Chongyu Jin
TLTianhao Liu
Tianhao Liu
SLShengxin Lin
Shengxin Lin
Liyi LiLiyi Li
Liyi Li
The triaxial fluxgate magnetometers (TFM) are widely used in space exploration, positioning and navigation, geological exploration, etc. As a high-precision vector magnetometer, the measurement accuracy will directly determine the accuracy of the obtained magnetic field data. The TFM has three kinds of own errors in measurement: zero offset error, proportional coefficient error and non-orthogonal error. These three kinds of errors will cause the TFM to deviate from the actual magnetic field value, and the fluxgate magnetometer needs to be calibrated. At present, the accuracy of the calibration method adopted by the fluxgate magnetometer depends on the stability of the natural environment magnetic field and the triaxial turntable (there is an uncontrollable residual magnetic interference), which limits the further improvement of the calibration accuracy. And due to the wide application of electromagnetic equipment, the natural electromagnetic environment is further damaged, and the calibration accuracy is subject to deterioration. In this paper, a magnetic shielded room (MSR) is used to provide a near-zero magnetic environment, and a triaxial uniform magnetic field coil (TUMC) is installed inside the MSR to construct a controllable arbitrary vector direction magnetic field, which solves the magnetic field disturbance problem of the original method. The TUMC and TFM error models were built and the MSR magnetic ambient noise model was added. The emphasis is on the degree of distortion of the magnetic field generated by the MSR as a ferromagnetic boundary condition and the influence of the deviation of the center point of TUMC on the calibration accuracy. Then, based on the above error model and magnetic environmental conditions, the calibration accuracy of the calibration magnetic field distribution is analyzed. Finally, the calibration experiment of the TFM is carried out by using the existing MSR, which proves the feasibility and effectiveness of the calibration method, and the method can greatly improve the calibration efficiency.

9 March 2018 in Energies
Verified
Journal Article
Open access
PDF file
CQCao Qinjie
Cao Qinjie
DPDonghua Pan
Donghua Pan
JLJi Li
Ji Li
YJYinxi Jin
Yinxi Jin
SZSun Zhiyin
Sun Zhiyin
Liyi LiLiyi Li
Liyi Li
Ultra-low magnetic fields have drawn lots of attention due to their important role in scientific and technological research. The combination of a magnetic shield and an active compensation coil is adopted in most high performance magnetically shielded rooms. Special consideration needs to be taken in the coil design since the magnetic shield significantly affects the uniformity of the magnetic field that is generated by the coil. An analytical model for the magnetic field calculation of the coil inside a cubic magnetic shield is proposed based on the generalized image method, which is validated by finite element analysis. A novel design method of the coil used in a cubic magnetic shield with a large homogeneous volume is proposed. The coil parameters are optimized to obtain a large cubic uniform volume with desired total deviation rate by discretizing the central volume in the coil. In the desired total deviation rate, the normalized usable volume of the new coil increases by 70% when compared with the Merritt coil. A coil system is developed according to the parameters obtained based on this method. The magnetic flux density and practical deviation rate of the coil are measured to validate the accuracy of this model and the feasibility of the design method. The experimental magnetic flux density agrees well with the analytical value. The maximum practical deviation rate of uniform volume of 0.8 × 0.8 × 0.8 m is in good agreement with the theoretical design value, taking into account the experiment errors.