Neutron radiography of irradiated nuclear fuel provides more comprehensive information about the internal condition of irradiated nuclear fuel than any other non-destructive technique to date. Idaho National Laboratory (INL) has multiple nuclear fuels research and development programs that routinely evaluate irradiated fuels using neutron radiography. The Neutron Radiography reactor (NRAD) sits beneath a shielded hot cell facility where neutron radiography and other evaluation techniques are performed on these highly radioactive objects. The NRAD currently uses the foil-film transfer technique for imaging fuel that is time consuming but provides high spatial resolution. This paper describes the NRAD and hot cell facilities, the current neutron radiography capabilities available at INL, planned upgrades to the neutron imaging systems, and new facilities being brought online at INL related to neutron imaging
1 February 2016 in Nuclear Engineering and Technology
The neutron radiography reactor (NRAD) is a 250 kW Mark-II Training, Research, Isotopes, General Atomics (TRIGA) reactor at Idaho National Laboratory, Idaho Falls, ID, USA. The East Radiography Station (ERS) is one of two neutron beams at the NRAD used for neutron radiography, which sits beneath a large hot cell and is primarily used for neutron radiography of highly radioactive objects. Additional fuel elements were added to the NRAD core in 2013 to increase the excess reactivity of the reactor, and may have changed some characteristics of the neutron beamline. This report discusses characterization of the neutron beamline following the addition of fuel to the NRAD. This work includes determination of the facility category according to the American Society for Testing and Materials (ASTM) standards, and also uses an array of gold foils to determine the neutron beam flux and evaluate the neutron beam profile. The NRAD ERS neutron beam is a Category I neutron radiography facility, the highest possible quality level according to the ASTM. Gold foil activation experiments show that the average neutron flux with length-to-diameter ratio (L/D) = 125 is 5.96 × 106 n/cm2/s with a 2σ standard error of 2.90 × 105 n/cm2/s. The neutron beam profile can be considered flat for qualitative neutron radiographic evaluation purposes. However, the neutron beam profile should be taken into account for quantitative evaluation
The Neutron Radiography Reactor at Idaho National Laboratory (INL) has two beamlines extending radially outward from the east and north faces of the reactor core. The control rod withdrawal procedure has recently been altered, potentially changing power distribution of the reactor and thus the properties of the neutron beams, calling for characterization of the neutron beams. The characterization of the East Radiography Station involved experiments used to measure the following characteristics: Neutron flux, neutron beam uniformity, cadmium ratio, image quality, and the neutron energy spectrum. The ERS is a Category-I neutron radiography facility signifying it has the highest possible rank a radiography station can achieve. The thermal equivalent neutron flux was measured using gold foil activation and determined to be 9.61 × 106 ± 2.47 × 105 n/cm2-s with a relatively uniform profile across the image plane. The cadmium ratio measurement was performed using bare and cadmium-covered gold foils and measured to be 2.05 ± 2.9%, indicating large epithermal and fast neutron content in the beam. The neutron energy spectrum was measured using foil activation coupled with unfolding algorithms provided by the software package Unfolding with MAXED and GRAVEL (UMG). The Monte-Carlo N-Particle (MCNP6) transport code was used to assist with the unfolding process. UMG, MCNP6, and measured foil activities were used to determine a neutron energy spectrum which was implemented into the MCNP6 model of the east neutron beam to contribute to future studies.
The Idaho National Laboratory supports multiple programs that are actively developing, testing, and evaluating new nuclear fuels including advanced commercial nuclear fuels, accident tolerant fuels, reduced-enrichment research reactor fuels, transmutation fuels, and advanced reactor fuels. Post irradiation examinations (PIE) of nondestructive and destructive techniques are performed at INL to research nuclear fuel behavior and performance under various conditions. The Neutron Radiography Reactor (NRAD) at INL is utilized to perform nondestructive examinations of irradiated nuclear fuels and the results of these examinations are used to aid in the decision making process for subsequent destructive exams. NRAD has historically performed transfer method neutron radiography with film as the imaging medium. This paper documents the effort to convert from film to computed radiography for PIE. Equipment selection, system characterization, and testing were performed as part of phase I. Phase II, as described in this paper, focuses on determining image resolution of the computed radiography system.
The Neutron Radiography Reactor (NRAD) at Idaho National Laboratory (INL) was designed for thermal and epithermal neutron radiography for examination of highly-radioactive irradiated nuclear fuel elements. Radioactive samples are remotely lowered into the East and North Radiography Stations (ERS and NRS, respectively), and a rail transfer system remotely positions radiography cassettes into the detector position for indirect radiography. The indirect transfer method with film has been used at NRAD for around forty years, but recent efforts seek to develop digital camera-based neutron imaging systems. Two initial camera detector systems were built using an inexpensive but high-quality scientific CMOS camera with robust shielding, and tests were performed in collaboration with Heinz Maier-Leibnitz Institut of Technische Universität München. The first measurements in the ERS provided valuable experience that informed the design of an improved neutron imaging system that was tested in the NRS. The first successful digital neutron computed tomography at INL was acquired, consisting of 421 neutron radiographs acquired in 4 hours. These first tests with camera-based neutron imaging systems have demonstrated the potential to both increase the throughput of radiography by two orders of magnitude and provide higher quality spatial information with three-dimensional tomographic reconstructions compared to two-dimensional radiographic projections, which represent a significant improvement compared to current film radiography capabilities.