Orda Baisanov

Orda Baisanov

Auto-generated profile, based on publicly available information

Orda Baisanov

Military Institute of Air Defense Forces, Aktobe, Kazakhstan

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2011 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
OBO.A. Baisanov
O.A. Baisanov
GDG.A. Doskeyev
G.A. Doskeyev
TDT.G. Doskeyev
T.G. Doskeyev
ISIgor Spivak-Lavrov
Igor Spivak-Lavrov

1 July 2011 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
OBO.A. Baisanov
O.A. Baisanov
GDG.A. Doskeyev
G.A. Doskeyev
ISIgor Spivak-Lavrov
Igor Spivak-Lavrov

1 January 2024 in Recent Contributions to Physics
Verified
Journal Article
Open access
PDF file
ISIgor Spivak-Lavrov
Igor Spivak-Lavrov
ААА.ш. Амантаева
А.ш. Амантаева
ОБО.а. Байсанов
О.а. Байсанов
ТШТ.ж. Шугаева
Т.ж. Шугаева
The concurrent utilization of electric and magnetic fields in static mass analyzers proves highly effective in sparticle separation solely based on their masses, thereby ensuring remarkable analytical capabilities. High-resolution mass analyzers employ an achromatizing electrostatic system to precisely focus ion radiation by energy. Devices featuring zero energy dispersion are created through the collaborative action of electric achromatizing systems and the magnetic field within the analyzer, resulting in ion separation based solely on mass. Expanding the ion beam prior to its magnetic field exposure enhances the overall quality of static mass analyzers. This article delves into a static mass analyzer with dual ion beam focusing, elucidating the ion acceleration and deceleration processes at electrode boundaries, their focalization via a transaxial lens, and the impact of the electrostatic prism's refractive surface on the mass analyzer's "quality" parameter. Additionally, the transition from a sector homogeneous magnetic field to the fields generated by a two-dimensional magnetic prism and a three-electrode transaxial focusing lens is explored to augment the mass analyzer's linear dispersion. To refine ion beam focus pre-magnetic field entry, the proposed adoption of a two-dimensional electrostatic prism promises heightened linear dispersion in the mass analyzer while expanding the beam pre-magnetic field entry. This study also examines the impact of a two-dimensional electric prism on the charged particle beam, presenting an approximate expression for its angular energy dispersion. It is demonstrated that a prism-based mass analyzer integrating two-dimensional electric and magnetic prisms enables energy-focused operations alongside enhanced linear dispersion and reduced linear dimensions.

23 December 2025 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
TSTilektes Shugayeva
Tilektes Shugayeva
ISIgor Spivak-Lavrov
Igor Spivak-Lavrov
OBOrda Baisanov
Orda Baisanov
AAAmangul Amantayeva
Amangul Amantayeva
This study explores a multi-reflection time-of-flight mass spectrometer (TOFMS) based on transaxial electrostatic mirrors providing spatial and energy time-of-flight focusing of the ion beam. Analysis of existing solutions reveals that spatial-energy time-of-flight focusing in compact TOFMSs is achieved using additional focusing elements, which complicates the design, limits resolution, and reduces sensitivity. This paper demonstrates that three-electrode transaxial mirrors enable simultaneous spatial and energy time-of-flight focusing of ions without the use of additional focusing elements. Monte Carlo simulation of the beam dynamics has made it possible to determine the trajectories and flight times of ions under various initial conditions. It was found that two closely spaced vertical focusing modes provide time-of-flight focusing of ions with a relative energy spread of . A mass resolution of 10,000 at half-maximum confirms the high efficiency of the proposed structure. The spatial distributions of the ion beam demonstrate stable focusing in the detector plane when modeling particles larger than 1000. The results are attributed to the features of transaxial geometry, which enables three-dimensional spatial and energy time-of-flight focusing. The practical significance of this work is the applicability of such multi-reflector mass analyzers in laboratory and space research where a combination of high resolution and instrument compactness is required