16 May 2013 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
SSSimon Stute
Simon Stute
CCClaude Comtat
Claude Comtat
Iterative reconstructions in positron emission tomography (PET) need a model relating the recorded data to the object/patient being imaged, called the system matrix (SM). The more realistic this model, the better the spatial resolution in the reconstructed images. However, a serious concern when using a SM that accurately models the resolution properties of the PET system is the undesirable edge artefact, visible through oscillations near sharp discontinuities in the reconstructed images. This artefact is a natural consequence of solving an ill-conditioned inverse problem, where the recorded data are band-limited. In this paper, we focus on practical aspects when considering image-based point-spread function (PSF) reconstructions. To remove the edge artefact, we propose to use a particular case of the method of sieves (Grenander 1981 Abstract Inference New York: Wiley), which simply consists in performing a standard PSF reconstruction, followed by a post-smoothing using the PSF as the convolution kernel. Using analytical simulations, we investigate the impact of different reconstruction and PSF modelling parameters on the edge artefact and its suppression, in the case of noise-free data and an exactly known PSF. Using Monte-Carlo simulations, we assess the proposed method of sieves with respect to the choice of the geometric projector and the PSF model used in the reconstruction. When the PSF model is accurately known, we show that the proposed method of sieves succeeds in completely suppressing the edge artefact, though after a number of iterations higher than typically used in practice. When applying the method to realistic data (i.e. unknown true SM and noisy data), we show that the choice of the geometric projector and the PSF model does not impact the results in terms of noise and contrast recovery, as long as the PSF has a width close to the true PSF one. Equivalent results were obtained using either blobs or voxels in the same conditions (i.e. the blob's density function being the same as the voxel-based PSF). From a practical point-of-view, the method can be used to perform fast reconstructions based on very simple models (compared to sinogram-based PSF modelling), producing artefact-free images with a better compromise between noise and spatial resolution than images reconstructed without or with under-estimated PSF. Besides, the method inherently limits the spatial resolution in the reconstructed images to the intrinsic one of the PET system.

8 October 2013 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
SBS Burg
S Burg
ADA Dupas
A Dupas
SSS Stute
S Stute
ADA Dieudonné
A Dieudonné
PHP Huet
P Huet
IBIrene Buvat
Irene Buvat
We evaluated the impact of partial volume effect (PVE) in the assessment of arterial diseases with 18FDG PET. An anthropomorphic digital phantom enabling the modeling of aorta related diseases like atherosclerosis and arteritis was used. Based on this phantom, we performed GATE Monte Carlo simulations to produce realistic PET images with a known organ segmentation and ground truth activity values. Images corresponding to 15 different activity-concentration ratios between the aortic wall and the blood and to 7 different wall thicknesses were generated. Using the PET images, we compared the theoretical wall-to-blood activity-concentration ratios (WBRs) with the measured WBRs obtained with five measurement methods: (1) measurement made by a physician (Expert), (2) automated measurement supposed to mimic the physician measurements (Max), (3) simple correction based on a recovery coefficient (Max-RC), (4) measurement based on an ideal VOI segmentation (Mean-VOI) and (5) measurement corrected for PVE using an ideal geometric transfer matrix (GTM) method. We found that Mean-VOI WBRs values were strongly affected by PVE. WBRs obtained by the physician measurement, by the Max method and by the Max-RC method were more accurate than WBRs obtained with the Mean-VOI approach. However Expert, Max and Max-RC WBRs strongly depended on the wall thickness. Only the GTM corrected WBRs did not depend on the wall thickness. Using the GTM method, we obtained more reproducible ratio values that could be compared across wall thickness. Yet, the feasibility of the implementation of a GTM-like method on real data remains to be studied.

4 September 2014 in IEEE Transactions on Image Processing
Verified
Journal Article
Closed access
VJVincent Jaouen
Vincent Jaouen
PGPaulo Gonzalez
Paulo Gonzalez
SSSimon Stute
Simon Stute
DGDenis Guilloteau
Denis Guilloteau
SCSylvie Chalon
Sylvie Chalon
CTClovis Tauber
Clovis Tauber
In this paper, we extend the gradient vector flow field for robust variational segmentation of vector-valued images. Rather than using scalar edge information, we define a vectorial edge map derived from a weighted local structure tensor of the image that enables the diffusion of the gradient vectors in accurate directions through the 4D gradient vector flow equation. To reduce the contribution of noise in the structure tensor, image channels are weighted according to a blind estimator of contrast. The method is applied to biological volume delineation in dynamic PET imaging, and validated on realistic Monte Carlo simulations of numerical phantoms as well as on real images.

21 March 2019 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
YCYanna Cruz Cavalcanti
Yanna Cruz Cavalcanti
TOThomas Oberlin
Thomas Oberlin
NDNicolas Dobigeon
Nicolas Dobigeon
CFCedric Fevotte
Cedric Fevotte
SSSimon Stute
Simon Stute
CTClovis Tauber
Clovis Tauber
Factor analysis has proven to be a relevant tool for extracting tissue time-activity curves (TACs) in dynamic PET images, since it allows for an unsupervised analysis of the data. Reliable and interpretable results are possible only if considered with respect to suitable noise statistics. However, the noise in reconstructed dynamic PET images is very difficult to characterize, despite the Poissonian nature of the count-rates. Rather than explicitly modeling the noise distribution, this work proposes to study the relevance of several divergence measures to be used within a factor analysis framework. To this end, the β-divergence, widely used in other applicative domains, is considered to design the data-fitting term involved in three different factor models. The performances of the resulting algorithms are evaluated for different values of β, in a range covering Gaussian, Poissonian and Gamma-distributed noises. The results obtained on two different types of synthetic images and one real image show the interest of applying non-standard values of β to improve factor analysis.

6 August 2018 in Medical Image Analysis
Verified
Journal Article
Closed access
PDF file
YCYanna Cruz Cavalcanti
Yanna Cruz Cavalcanti
TOThomas Oberlin
Thomas Oberlin
NDNicolas Dobigeon
Nicolas Dobigeon
SSSimon Stute
Simon Stute
MRMaria Ribeiro
Maria Ribeiro
CTClovis Tauber
Clovis Tauber

16 September 2021 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
ZCZacharias Chalampalakis
Zacharias Chalampalakis
SSSimon Stute
Simon Stute
MFMarina Filipović
Marina Filipović
FSFlorent Sureau
Florent Sureau
CCClaude Comtat
Claude Comtat
Dynamic whole body (DWB) PET acquisition protocols enable the use of whole body parametric imaging for clinical applications. In FDG imaging, accurate parametric images of Patlak K i can be complementary to regular standardised uptake value images and improve on current applications or enable new ones. In this study we consider DWB protocols implemented on clinical scanners with a limited axial field of view with the use of multiple whole body sweeps. These protocols result in temporal gaps in the dynamic data which produce noisier and potentially more biased parametric images, compared to single bed (SB) dynamic protocols. Dynamic reconstruction using the Patlak model has been previously proposed to overcome these limits and shown improved DWB parametric images of K i . In this work, we propose and make use of a spectral analysis based model for dynamic reconstruction and parametric imaging of Patlak K i . Both dynamic reconstruction methods were evaluated for DWB FDG protocols and compared against 3D reconstruction based parametric imaging from SB dynamic protocols. This work was conducted on simulated data and results were tested against real FDG dynamic data. We showed that dynamic reconstruction can achieve levels of parametric image noise and bias comparable to 3D reconstruction in SB dynamic studies, with the spectral model offering additional flexibility and further reduction of image noise. Comparisons were also made between step and shoot and continuous bed motion (CBM) protocols, which showed that CBM can achieve lower parametric image noise due to reduced acquisition temporal gaps. Finally, our results showed that dynamic reconstruction improved VOI parametric mean estimates but did not result to fully converged values before resulting in undesirable levels of noise. Additional regularisation methods need to be considered for DWB protocols to ensure both accurate quantification and acceptable noise levels for clinical applications.