1 November 2026 in The Journal of the Acoustical Society of America
Nasometers compute nasalance using microphones on each face of a rigid separation plate held at the philtrum. The manufacturer of the Pentax Nasometer specifies 25 dB of channel separation, but no methodological details accompany this value. This study quantifies acoustic isolation of the Nasometer separation plate from 100 to 7000 Hz, examining source amplitude, microphone position, and plate geometry. Tonal sweeps were performed in an anechoic chamber with microphones on each plate face. Within the 350–750 Hz nasalance band, the oral-to-nasal sound pressure level (SPL) difference (ΔSPL) for the clinical plate ranged from 10 to 15 dB, substantially below the manufacturer's specification. Leakage was largely level-independent, reflecting acoustic geometry rather than source amplitude. Moving the microphones to the lateral plate edge further reduced acoustic isolation, with ΔSPL falling to 6–12 dB. A larger custom plate at a matched microphone distance improved ΔSPL to 16–22.5 dB. Schlieren imaging with spectral proper orthogonal decomposition confirmed edge diffraction as the dominant leakage mechanism. For the clinical plate, the measured separations correspond to leakage nasalance contributions of approximately 15%–24%, overlapping published normative oral-speech scores and indicating plate-induced crosstalk is a clinically meaningful source of bias in nasalance measurements.