Sungtae Kim

Sungtae Kim

Auto-generated profile, based on publicly available information

Sungtae Kim

Department of Periodontology, School of Dentistry and Dental Research Institute Seoul National University and Seoul National University Dental Hospital Seoul Republic of Korea

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 August 2019 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
SPShin-Young Park
Shin-Young Park
KKKyoung-Hwa Kim
Kyoung-Hwa Kim
SKSungtae Kim
Sungtae Kim
YLYong-Moo Lee
Yong-Moo Lee
YSYang-Jo Seol
Yang-Jo Seol
Bone morphogenetic protein-2 (BMP-2) is a potent growth factor affecting bone formation. While recombinant human BMP-2 (rhBMP-2) has been commercially available in cases of non-union fracture and spinal fusion in orthopaedics, it has also been applied to improve bone regeneration in challenging cases requiring dental implant treatment. However, complications related to an initially high dosage for maintaining an effective physiological concentration at the defect site have been reported, although an effective and safe rhBMP-2 dosage for bone regeneration has not yet been determined. In contrast to protein delivery, BMP-2 gene transfer into the defect site induces BMP-2 synthesis in vivo and leads to secretion for weeks to months, depending on the vector, at a concentration of nanograms per milliliter. BMP-2 gene delivery is advantageous for bone wound healing process in terms of dosage and duration. However, safety concerns related to viral vectors are one of the hurdles that need to be overcome for gene delivery to be used in clinical practice. Recently, commercially available gene therapy has been introduced in orthopedics, and clinical trials in dentistry have been ongoing. This review examines the application of BMP-2 gene therapy for bone regeneration in the oral and maxillofacial regions and discusses future perspectives of BMP-2 gene therapy in dentistry.

1 May 2009 in Journal of Craniofacial Surgery
Verified
Journal Article
Closed access
SKSung Tae Kim
Sung Tae Kim
KHKyung-Seok Hu
Kyung-Seok Hu
WSWu-Chul Song
Wu-Chul Song
MKMin-Kyu Kang
Min-Kyu Kang
HPHyun-Do Park
Hyun-Do Park
HKHee-Jin Kim
Hee-Jin Kim
The purposes of this study were to locate the constant anatomic landmarks, which are very important and helpful for endoscopic surgery and not well described for the pterygopalatine fossa (PPF) surgery via the middle nasal meatus-sphenopalatine foramen approach to establish a safe surgical mode. Eight cases of adult skull specimens were selected for the simulated surgery. The Messerklinger surgical approach was used under the endoscope. The uncinate process was removed successively, and the anterior ethmoid sinus and posterior ethmoid sinus were opened. The opening of the maxillary sinus was identified and was expanded forward and backward. The ethmoidal crest was found and was used as an anatomic landmark to find the sphenopalatine foramen. The sphenopalatine artery was protected and was used as a guide to enter the PPF region. The sphenopalatine artery was followed conversely to anatomize the blood vessels and nerves in the PPF. It was found that our surgical procedure provides a clear view of the constant anatomic landmark including ethmoidal crest and sphenopalatine foramen. By retrograde dissection, following the sphenopalatine artery, which runs out of the sphenopalatine foramen behind the ethmoidal crest, the internal maxillary artery (IMA) and the branches of the IMA in the PPF were exposed. Posterior to the sphenopalatine artery, the typical Y-shaped structure with the pterygopalatine ganglion as the center was visible when the IMA and its branches were moved downward and outward. The Y structure, which is consisted of the pterygopalatine ganglion, branches of the internal maxillary nerve, vidian nerve, and descending palatine nerve, served as the other anatomic landmark. By following the Y structure, it was easy to locate the pterygoid canal, foramen rotundum, and the infraorbital nerve, and the integrity of the nerve structure could be protected. Endoscopic PPF surgery via the middle nasal meatus-sphenopalatine foramen approach is safe, and the ethmoidal crest, sphenopalatine foramen, and Y structure with the pterygopalatine ganglion in the center are important anatomic landmarks that can be referred to during the surgery.

1 January 2014 in The International Journal of Oral and Maxillofacial Implants
Verified
Journal Article
Closed access
HHHyun-Jin Han
Hyun-Jin Han
SKSungtae Kim
Sungtae Kim
DHDong-Hoo Han
Dong-Hoo Han
Hyun-Jin Han, DDS, MS/Sungtae Kim, DDS, PhD/Dong-Hoo Han, DDS, PhD: Purpose: Dental implants generally provide good results as replacements for missing teeth, but a few patients experience implant failure. The aim of this retrospective study was to analyze the characteristics and causes of implant failures in hopes of reducing future failures. Materials and Methods: Patients who received one or more implants at the Dental Hospital of Yonsei University College of Dentistry between February 1991 and May 2009 were included in this study. Data including age, sex, medical history, habits (eg, smoking and drinking), bone quality, primary stability, implant size, implant surface, additional surgical procedures, prosthetic type, clinical symptoms, implant failure date, and causes of implant failure were obtained through a chart review. Follow-up radiographs were compared to those obtained at baseline. The Pearson chi-square test and Fisher exact test were used to evaluate the correlations between risk factors and implant failure. Results: In total, 879 patients received 2,796 implants; 150 implants in 91 patients had failed. Early and late implant failures occurred with 86 (57.3%) and 64 (42.7%) implants, respectively. The main causes of early and late implant failures were inflammation (47%) and overloading (53%), respectively. When the cause of early implant failure was inflammation, the failure rate was significantly higher for implants in the anterior maxilla; implants with poor primary stability, a machined surface, or a length exceeding 15 mm; and implants placed with a reconstructive procedure and two-stage surgery. When late implant failure was caused by overloading, the failure rate was significantly higher for implants with a machined surface, placed with a reconstructive procedure and/or two-stage surgery, and supporting telescopic dentures. Conclusion: Within the limitations of this study, the major causes of implant failure are inflammation and overloading, and they differ between early and late implant failures.

1 March 2013 in The International Journal of Oral and Maxillofacial Implants
Verified
Journal Article
Closed access
SKSungtae Kim
Sungtae Kim
YLYoon-Jin Lee
Yoon-Jin Lee
SLSojin Lee
Sojin Lee
Hong Seok MoonHong Seok Moon
Hong Seok Moon
MCMoon-Kyu Chung
Moon-Kyu Chung
Sungtae Kim, DDS, PhD/Yoon-Jin Lee, DDS, MS/Sojin Lee, DDS/Hong-Seok Moon, DDS, PhD/Moon-Kyu Chung, DDS, PhD: Purpose: To investigate the change in 89 patients? pain and anxiety following implant surgery and to evaluate the correlation among anxiety, pain, and influencing factors. Materials and Methods: Eighty-nine patients were included in this study. Subjective factors influencing pain perception included anxiety from the overall dental treatment (scored on the Dental Anxiety Scale [DAS]) and anxiety relative to the time from implant surgery. Objective factors were sex, age, and implant location and number. Patients completed questionnaires just before surgery (T0), immediately after surgery (T1), 1 day after surgery (T2), and 1 week after surgery (T3). Results: The average pain perception was highest at T2, followed by T1 and T3. Pain perception at T1 was significantly higher in women and for a larger number of implant placements. Pain perception at T2 was significantly higher in women and when DAS and anxiety scores were high. The pain score at T3 was significantly higher in women and when anxiety scores were high. The results from multiple linear regression analysis showed that pain perception was significantly higher at T1 in women and for a larger number of implant placements, and at T3 when the dental anxiety score was high. Conclusion: Within the limitations of this study, a patient?s anxiety represented by dental anxiety score and state of anxiety scores affected pain intensity 1 day after implant surgery. Sex and the number of implants affected pain intensity immediately after implant surgery. Patients who have high pain intensity 1 week after implant surgery showed high pain intensity at each time point. Int J Oral Maxillofac Implants 2013:28;531?535. doi: 10.11607/jomi.2713

1 January 2016 in Journal of Periodontal & Implant Science
Verified
Journal Article
Open access
PDF file
YKYun-Jeong Kim
Yun-Jeong Kim
Ji-Man ParkJi-Man Park
Ji-Man Park
SKSungtae Kim
Sungtae Kim
KKKi-Tae Koo
Ki-Tae Koo
YSYang-Jo Seol
Yang-Jo Seol
YKYoung Ku
Young Ku
Kim YJ, et al. J Periodontal Implant Sci. 2016 Dec;46(6):372-381. https://doi.org/10.5051/jpis.2016.46.6.372

5 August 2022 in Materials
Verified
Journal Article
Open access
PDF file
JMJoon-Mo Moon
Joon-Mo Moon
CJChang-Sub Jeong
Chang-Sub Jeong
HLHee-Jeong Lee
Hee-Jeong Lee
JBJi-Myung Bae
Ji-Myung Bae
Eun Joo ChoiEun Joo Choi
Eun Joo Choi
Seunghan OhSeunghan Oh
Seunghan Oh
This study was aimed at preparing zirconia samples via additive manufacturing (AM) and subtractive manufacturing (SM) and testing the following aspects: (1) the manufacturing accuracy of the zirconia samples and (2) the bond strength of porcelain to zirconia to evaluate the applicability of the zirconia fabricated by AM in dental clinics. We used three milling machines for SM (AR, K5, and UP) and a 3D printer for AM (AO). The manufacturing accuracy of the zirconia specimen in the internal and marginal areas was evaluated by superimposing techniques to calculate the root mean square (RMS) values. The bond strengths of porcelain to zirconia prepared via SM and AM were measured using a universal testing machine. The internal and marginal RMS values of the zirconia prepared by AM (AO) were within the range of those of the zirconia prepared by SM (AR, K5, and UP). Moreover, the bond strength value of the zirconia prepared by AM (35.12 ± 4.09 MPa) was significantly higher than that of the zirconia prepared by SM (30.26 ± 5.20 MPa). Therefore, AM technology has significant potential for applications in dentistry.