Joshua F. P. van Amerom

Joshua F. P. van Amerom

Auto-generated profile, based on publicly available information

Joshua F. P. van Amerom

School of Biomedical Engineering & Imaging Sciences, King’s College London, London, SE1 7EH, UK

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2014 in Circulation: Cardiovascular Imaging
Verified
Journal Article
Closed access
PDF file
MPMilan Prsa
Milan Prsa
LSLiqun Sun
Liqun Sun
JAJoshua van Amerom
Joshua van Amerom
SYShi-Joon Yoo
Shi-Joon Yoo
LGLars Grosse-Wortmann
Lars Grosse-Wortmann
MSMike Seed
Mike Seed
Background—: Phase-contrast MRI with metric-optimized gating is a promising new technique for studying the distribution of the fetal circulation. However, mean and reference ranges for blood flow measurements made in the major fetal vessels using this technique are yet to be established. Methods and Results—: We measured flow in the major vessels of the fetal circulation in 40 late-gestation normal human fetuses using phase-contrast MRI (mean gestational age, 37 [SD=1.1] weeks). Flows were indexed to the fetal weight, which was estimated from the fetal volume calculated by MRI segmentation. The following mean flows (in mL/min per kilogram; ±2SD) were obtained: combined ventricular output, 465 (351, 579); main pulmonary artery, 261 (169, 353); ascending aorta, 191 (121, 261); superior vena cava, 137 (77, 197); ductus arteriosus, 187 (109, 265); descending aorta, 252 (160, 344); pulmonary blood flow, 77 (0, 160); umbilical vein, 134 (62, 206); and foramen ovale, 135 (37, 233). Expressed as percentages of the combined ventricular output, the mean flows±2 SD were as follows: main pulmonary artery, 56 (44, 68); ascending aorta, 41 (29, 53); superior vena cava, 29 (15, 43); ductus arteriosus, 41 (25, 57); descending aorta, 55 (35, 75); pulmonary blood flow, 16 (0, 34); umbilical vein, 29 (11, 47); and foramen ovale, 29 (7, 51). A strong inverse relationship between foramen ovale shunt and pulmonary blood flow was noted ( r =−0.64; P <0.0001). Conclusions—: Although too small a sample size to provide normal ranges, these results are in keeping with those predicted in humans based on measurements made in fetal lambs using radioactive microspheres and provide preliminary reference ranges for the late-gestation human fetuses. The wide range we found in foramen ovale shunting suggests a degree of variability in the way blood is streamed through the fetal circulation.

1 April 2019 in The Lancet
Verified
Journal Article
Open access
DLDavid Lloyd
David Lloyd
KPKuberan Pushparajah
Kuberan Pushparajah
JSJohn Simpson
John Simpson
JAJoshua F P van Amerom
Joshua F P van Amerom
MPMilou P M van Poppel
Milou P M van Poppel
RRReza Razavi
Reza Razavi
Two-dimensional (2D) ultrasound echocardiography is the primary technique used to diagnose congenital heart disease before birth. There is, however, a longstanding need for a reliable form of secondary imaging, particularly in cases when more detailed three-dimensional (3D) vascular imaging is required, or when ultrasound windows are of poor diagnostic quality. Fetal MRI, which is well established for other organ systems, is highly susceptible to fetal movement, particularly for 3D imaging. The objective of this study was to investigate the combination of prenatal MRI with novel, motion-corrected 3D image registration software, as an adjunct to fetal echocardiography in the diagnosis of congenital heart disease. Pregnant women carrying a fetus with known or suspected congenital heart disease were recruited via a tertiary fetal cardiology unit. After initial validation experiments to assess the general reliability of the approach, MRI data were acquired in 85 consecutive fetuses, as overlapping stacks of 2D images. These images were then processed with a bespoke open-source reconstruction algorithm to produce a super-resolution 3D volume of the fetal thorax. These datasets were assessed with measurement comparison with paired 2D ultrasound, structured anatomical assessment of the 2D and 3D data, and contemporaneous, archived clinical fetal MRI reports, which were compared with postnatal findings after delivery. Between Oct 8, 2015, and June 30, 2017, 101 patients were referred for MRI, of whom 85 were eligible and had fetal MRI. The mean gestational age at the time of MRI was 32 weeks (range 24-36). High-resolution (0·50-0·75 mm isotropic) 3D datasets of the fetal thorax were generated in all 85 cases. Vascular measurements showed good overall agreement with 2D echocardiography in 51 cases with paired data (intra-class correlation coefficient 0·78, 95% CI 0·68-0·84), with fetal vascular structures more effectively visualised with 3D MRI than with uncorrected 2D MRI (657 [97%] of 680 anatomical areas identified vs 358 [53%] of 680 areas; p<0·0001). When a structure of interest was visualised in both 2D and 3D data (n=358), observers gave a higher diagnostic quality score for 3D data in 321 (90%) of cases, with 37 (10%) scores tied with 2D data, and no lower scores than for 2D data (Wilcoxon signed rank test p<0·0001). Additional anatomical features were described in ten cases, of which all were confirmed postnatally. Standard fetal MRI with open-source image processing software is a reliable method of generating high-resolution 3D imaging of the fetal vasculature. The 3D volumes produced show good spatial agreement with ultrasound, and significantly improved visualisation and diagnostic quality compared with source 2D MRI data. This freely available combination requires minimal infrastructure, and provides safe, powerful, and highly complementary imaging of the fetal cardiovascular system. Wellcome Trust/EPSRC Centre for Medical Engineering, National Institute for Health Research.

1 January 2012 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
MSMike Seed
Mike Seed
JAJoshua F P van Amerom
Joshua F P van Amerom
SYShi-Joon Yoo
Shi-Joon Yoo
BNBahiyah Al Nafisi
Bahiyah Al Nafisi
LGLars Grosse-Wortmann
Lars Grosse-Wortmann
CMChristopher K Macgowan
Christopher K Macgowan
We present the first phase contrast (PC) cardiovascular magnetic resonance (CMR) measurements of the distribution of blood flow in twelve late gestation human fetuses. These were obtained using a retrospective gating technique known as metric optimised gating (MOG).

26 October 2010 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
MJMichael S. Jansz
Michael S. Jansz
MSMike Seed
Mike Seed
JAJoshua F. P. van Amerom
Joshua F. P. van Amerom
DWDerek Wong
Derek Wong
LGLars Grosse‐Wortmann
Lars Grosse‐Wortmann
CMChristopher K. Macgowan
Christopher K. Macgowan
Phase‐contrast magnetic resonance imaging can be used to complement echocardiography for the evaluation of the fetal heart. Cardiac imaging typically requires gating with peripheral hardware; however, a gating signal is not readily available in utero. No successful application of existing technologies to human fetal phase‐contrast magnetic resonance imaging has been reported to date in the literature. The purpose of this work is to develop a technique for phase‐contrast magnetic resonance imaging of the fetal heart that does not require measurement of a gating signal. Metric optimized gating involves acquiring data without gating and retrospectively determining the proper reconstruction by optimizing an image metric. The effects of incorrect gating on phase contrast images were investigated, and the time‐entropy of the series of images was found to provide a good measure of the level of corruption. The technique was validated with a pulsatile flow phantom, experiments with adult volunteers, and in vivo application in the fetal population. Images and flow curves from these measurements are presented. Additionally, numerical simulations were used to investigate the degree to which heart rate variability affects the reconstruction process. Metric optimized gating enables imaging with conventional phase‐contrast magnetic resonance imaging sequences in the absence of a gating signal, permitting flow measurements in the great vessels in utero. Magn Reson Med, 2010.

1 January 2013 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
BNBahiyah Al Nafisi
Bahiyah Al Nafisi
JAJoshua Fp van Amerom
Joshua Fp van Amerom
JFJonathan Forsey
Jonathan Forsey
EJEdgar Jaeggi
Edgar Jaeggi
LGLars Grosse-Wortmann
Lars Grosse-Wortmann
MSMike Seed
Mike Seed
The distribution of blood flow in fetuses with congenital heart disease (CHD) is likely to influence fetal growth, organ development, and postnatal outcome, but has previously been difficult to study. We present the first measurements of the distribution of the fetal circulation in left-sided CHD made using phase contrast cardiac magnetic resonance (CMR).

1 October 2019 in Topics in Magnetic Resonance Imaging
Verified
Journal Article
Open access
CRChristopher W. Roy
Christopher W. Roy
JAJoshua F.P. van Amerom
Joshua F.P. van Amerom
DMDavide Marini
Davide Marini
MSMike Seed
Mike Seed
CMChristopher K. Macgowan
Christopher K. Macgowan
Magnetic resonance imaging (MRI) is an appealing technology for fetal cardiovascular assessment. It can be used to visualize fetal cardiac and vascular anatomy, to quantify fetal blood flow, and to quantify fetal blood oxygen saturation and hematocrit. However, there are practical limitations to the use of conventional MRI for fetal cardiovascular assessment, including the small size and high heart rate of the human fetus, the lack of conventional cardiac gating methods to synchronize data acquisition, and the potential corruption of MRI data due to maternal respiration and unpredictable fetal movements. In this review, we discuss recent technical advances in accelerated imaging, image reconstruction, cardiac gating, and motion compensation that have enabled dynamic MRI of the fetal heart.