29 July 2014 in Radiation Oncology
In radiotherapy treatment planning, intravenous administration of an iodine-based contrast agent during computed tomography (CT) improves the accuracy of delineating target volumes. However, increased tissue attenuation resulting from the high atomic number of iodine may result in erroneous dose calculations because the contrast agent is absent during the actual procedure. The purpose of this proof-of-concept study was to present a novel framework to improve the accuracy of dose calculations using dual-energy virtual unenhanced CT in the presence of an iodine-based contrast agent. Simple phantom experiments were designed to assess the feasibility of the proposed concept. By utilizing a “second-generation” dual-source CT scanner equipped with a tin filter for improved spectral separation, four CT datasets were obtained using both a water phantom and an iodine phantom: “true unenhanced” images with attenuation values of 2 ± 11 Hounsfield Units (HU), “enhanced” images with attenuation values of 274 ± 23 HU, and two series of “virtual unenhanced” images synthesized from dual-energy scans of the iodine phantom, each with a different combination of tube voltages. Two series of virtual unenhanced images demonstrated attenuation values of 12 ± 29 HU (with 80 kVp/140 kVp) and 34 ± 10 HU (with 100 kVp/140 kVp) after removing the iodine component from the contrast-enhanced images. Dose distributions of the single photon beams calculated from the enhanced images and two series of virtual unenhanced images were compared to those from true unenhanced images as a reference. The dose distributions obtained from both series of virtual unenhanced images were almost equivalent to that from the true unenhanced images, whereas the dose distribution obtained from the enhanced images indicated increased beam attenuation caused by the high attenuation characteristics of iodine. Compared to the reference dose distribution from the true unenhanced images, the dose distribution pass rates from both series of virtual unenhanced images were greater than 90%, while those from the enhanced images were less than approximately 50–60%. Dual-energy virtual unenhanced CT improves the accuracy of dose distributions in radiotherapy treatment planning by removing the iodine component from contrast-enhanced images.
9 April 2013 in Radiation Oncology
Recent work by Saito (2012) has demonstrated a simple conversion from energy-subtracted computed tomography (CT) values (ΔHU) obtained using dual-energy CT to relative electron density (RED) via a single linear relationship. The purpose of this study was to investigate the feasibility of this method to obtain RED from virtual monochromatic CT images obtained by the gemstone spectral imaging (GSI) mode with fast-kVp switching. A tissue characterization phantom with 13 inserts made of different materials was scanned using the GSI mode on a Discovery CT750 HD. Four sets of virtual monochromatic CT images (60, 77, 100 and 140 keV) were obtained from a single GSI acquisition. When we define Δ HU in terms of the weighting factor for the subtraction α, Δ HU ≡ (1 + α)H - αL (H and L represent the CT values for high and low energy respectively), the relationship between Δ HU and RED is approximated as a linear function, a × Δ HU/1000 + b (a, b = unity). We evaluated the agreement between the determined and nominal RED. We also have investigated reproducibility over short and long time periods. For the 13 insert materials, the RED determined by monochromatic CT images agreed with the nominal values within 1.1% and the coefficient of determination for this calculation formula was greater than 0.999. The observed reproducibility (1 standard deviation) of calculation error was within 0.5% for all materials. These findings indicate that virtual monochromatic CT scans at two different energies using GSI mode can provide an accurate method for estimating RED.
1 January 2006 in Magnetic Resonance in Medical Sciences
Air microbubbles have been investigated recently at high magnetic field strength (2 Tesla or greater) as potential MR susceptibility contrast agents. We used a phantom to measure their susceptibility at 1.5T to clarify their usefulness for this purpose. The phantom, filled with fresh Levovist® suspension at 4 different doses (67 to 125 mg/mL), was continuously scanned with a gradient-echo technique at a temporal resolution of 10 s. The transverse relaxation increase (R2*) by microbubbles demonstrated a time course of exponential decay at each dose (time-constant, 39 to 57 s). The dependency of R2* on microbubble volume fraction was linear, with a slope of 89 s-1 per percentage microbubble volume fraction. Our study represents the first step towards applying microbubbles as susceptibility contrast agents at 1.5T.
17 May 2011 in Journal of Magnetic Resonance Imaging
Purpose: To evaluate the potential of tetrahedral diffusion‐weighted imaging (DWI) compared to orthogonal DWI for detection and localization of early enhanced breast mass lesions at 1.5T. Materials and Methods: Sixty‐seven consecutive patients (mean age 51.7 years, range 14–84 years) with 68 solitary early enhanced breast lesions suspicious for cancer on dynamic contrast‐enhanced magnetic resonance imaging (MRI) were enrolled in this retrospective study. Two radiologists independently observed maximum intensity projection images of orthogonal and tetrahedral DWI and the diagnostic accuracy and background tissue visibility between two DWI techniques were compared. Contrast‐enhanced MRI was used as the reference standard. Background tissue visibility was assessed based on whether the “breast quadrant” and “skin line” were determined. A phantom validation study for apparent diffusion coefficient (ADC) values was also conducted. Results: Sensitivity (93%) and specificity (96%) on tetrahedral DWI were equivalent to those on orthogonal DWI (sensitivity, 88%; specificity, 95%). Background tissue was more easily determined with tetrahedral DWI (breast quadrant, 90%; skin lines, 95%) than with orthogonal DWI (breast quadrant, 61%; skin lines, 16%). ADC values of tetrahedral DWI were highly correlated with those of orthogonal DWI. Conclusion: Tetrahedral DWI provided equivalent detectability of mass lesions with improved visibility of surrounding anatomical structure. J. Magn. Reson. Imaging 2011;33:1375–1381.
1 January 2006 in Radiation Medicine
18 July 2006 in Radiation Medicine