Sebastian Wojcinski

Sebastian Wojcinski

Auto-generated profile, based on publicly available information

Sebastian Wojcinski

Zentrum für Frauenheilkunde, Brustzentrum, Universitätsklinikum OWL, Bielefeld, Germany

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2010 in Ultraschall in der Medizin - European Journal of Ultrasound
Verified
Journal Article
Closed access
PDF file
SWS. Wojcinski
S. Wojcinski
AFA. Farrokh
A. Farrokh
SWS. Weber
S. Weber
ATA. Thomas
A. Thomas
TFT. Fischer
T. Fischer
FDF. Degenhardt
F. Degenhardt
Ziel: Die Hitachi Real-time Tissue Elastography (HI-RTE) erlaubt eine sonografische Abschätzung der Gewebeelastizität. Wir haben untersucht, ob durch die Sonoelastografie eine exaktere Vorhersage der Dignität von Brustläsionen möglich ist. Material und Methoden: In einer multizentrischen Studie wurden 779 Brustläsionen sonografisch untersucht und anschließend histologisch gesichert. Wir präsentieren die Ergebnisse der 3 Studienzentren (Berlin, Bielefeld, Homburg/Saar) in Hinblick auf Sensitivität (SE), Spezifität (SP) und prädiktive Werte (PPV, NPV) der Methode. Zusätzlich wurde eine Auswertung der Pretest- und Posttest-Krankheitswahrscheinlichkeit (POD) bei BI-RADS®-US-3- und -4-Befunden durchgeführt, da gerade in dieser Kategorie eine genauere Aussage über die Dignität der Läsionen wünschenswert ist. Ergebnisse: Die Sonoelastografie zeigte im Vergleich zum konventionellen Ultraschall eine verbesserte SP (89,5 % versus 76,1 %) und einen hohen PPV (86,6 % versus 77,2 %). Insbesondere in der dichten Brust (ACR III-IV) konnte eine noch höhere SP für die Methode nachgewiesen werden (92,8 %). Bei BI-RADS-US-3-Läsionen erhöhte ein auffälliges Elastogramm die Krankheitswahrscheinlichkeit signifikant von 8,3 % auf eine Posttest-POD von 45,5 %. Die Pretest-POD bei BI-RADS-US-4-Läsionen betrug 56,6 %. Bei einem unauffälligen Elastogramm sank die Posttest-POD signifikant auf 24,2 %, bei einem auffälligen Elastogramm stieg sie signifikant auf 81,5 %. Schlussfolgerung: Die Daten demonstrieren, dass durch die Sonoelastografie eine höhere diagnostische Genauigkeit erzielt werden kann. Wir stellen ein Protokoll zur Diskussion, wie die Sonoelastografie zukünftig in die Routinediagnostik integriert werden könnte. Purpose: Hitachi real-time tissue elastography (HI-RTE) is an ultrasound technique that facilitates the estimation of tissue elasticity. Our study evaluates whether sonoelastography improves the differentiation of benign and malignant breast lesions. Materials and Methods: In a multicenter approach sonoelastography of focal breast lesions was carried out in 779 patients with subsequent histological confirmation. We present data from 3 study centers (Berlin, Bielefeld, Homburg/Saar) focusing on the sensitivity (SE), specificity (SP) and the positive (PPV) and negative predictive value (NPV) of sonoelastography. In addition we performed an analysis of the diagnostic performance, expressed by the pretest and posttest probability of disease (POD), in BI-RADS®-US 3 or 4 lesions as these categories can imply both malignant and benign lesions and a more precise prediction would be a preferable aim. Results: Sonoelastography demonstrated an improved SP (89.5 %) and an excellent PPV (86.8 %) compared to B-mode ultrasound (76.1 % and 77.2 %). Especially in dense breasts ACR III-IV, the SP was even higher (92.8 %). In BI-RADS-US 3 lesions, a suspicious elastogram significantly modified the POD from 8.3 % to a posttest POD of 45.5 %. In BI-RADS-US 4 lesions, we found a pretest POD of 56.6 %. The posttest POD changed significantly to 24.2 % with a normal elastogram and to 81.5 % with a suspicious elastogram. Conclusion: Our data demonstrates that the complementary use of sonoelastography definitely improves the performance in breast diagnostics. Finally we present a protocol of how sonoelastography can be integrated into our daily practice.

1 October 2012 in Journal of Ultrasound in Medicine
Verified
Journal Article
Open access
PDF file
SWSebastian Wojcinski
Sebastian Wojcinski
ASAmr A. Soliman
Amr A. Soliman
JSJulia Schmidt
Julia Schmidt
LMLars Makowski
Lars Makowski
FDFriedrich Degenhardt
Friedrich Degenhardt
PHPeter Hillemanns
Peter Hillemanns
Objectives Triple‐negative breast cancer (TNBC) is known to have unique molecular, clinical, and pathologic characteristics. The growth pattern of this cancer may also affect its appearance on sonography. Our study evaluated the sonographic features of TNBC according to the American College of Radiology Breast Imaging Reporting and Data System sonographic classification system and compared these features with those of non‐TNBC. Methods Data from 315 consecutive breast cancer cases were collected. The images were reevaluated by an examiner blinded to the patients' characteristics and histologic results according to the Breast Imaging Reporting and Data System. The sonographic features of TNBC (n = 33) and non‐TNBC (n = 282) were compared. Results Triple‐negative breast cancer was significantly correlated with a younger patient age (P = .002) and was associated with higher tumor grades (P < .001), more lymph node involvement (P = .014), and a trend toward a larger tumor size. With regard to sonographic features, the margin of TNBC was more frequently described as lobulated or microlobulated (75.8% versus 49.5% in non‐TNBC; P = .005). The echoic halo was observed significantly less often in TNBC than in non‐TNBC(39.4% versus 62.8%; P = .014). Cooper ligaments were displaced rather than disrupted in TNBC compared to non‐TNBC (P = .003). Regarding the posterior acoustic features, enhancement was observed significantly more often in TNBC (36.4% versus 13.0% in non‐TNBC; P = .031). Conclusions Triple‐negative breast cancer and non‐TNBC have different sonographic features. This finding can be explained by the pathologic profile of this breast cancer subtype. Some of the distinct sonographic criteria for TNBC are more likely to be associated with benign masses. Knowledge of the distinct sonographic features of TNBC would help the examiner avoid false‐negative classification of this tumor type.

1 October 2011 in International Journal of Women's Health
Verified
Journal Article
Open access
PDF file
SWSebastian Wojcinski
Sebastian Wojcinski
AFAndre Farrokh
Andre Farrokh
UHUrsula Hille
Ursula Hille
JWJakub Wiskirchen
Jakub Wiskirchen
SGSamuel Gyapong
Samuel Gyapong
ASAmr A Soliman
Amr A Soliman
The idea of an automated whole breast ultrasound was developed three decades ago. We present our initial experiences with the latest technical advance in this technique, the automated breast volume scanner (ABVS) ACUSON S2000TM. Volume data sets were collected from 50 patients and a database containing 23 women with no detectable lesions in conventional ultrasound (BI-RADS®-US 1), 13 women with clearly benign lesions (BI-RADS®-US 2), and 14 women with known breast cancer (BI-RADS®-US 5) was created. An independent examiner evaluated the ABVS data on a separate workstation without any prior knowledge of the patients’ histories. The diagnostic accuracy for the experimental ABVS was 66.0% (95% confidence interval [CI]: 52.9–79.1). The independent examiner detected all breast cancers in the volume data resulting in a calculated sensitivity of 100% in the described setting (95% CI: 73.2%–100%). After the ABVS examination, there were a high number of requests for second-look ultrasounds in 47% (95% CI: 30.9–63.5) of the healthy women (with either a clearly benign lesion or no breast lesions at all in conventional handheld ultrasound). Therefore, the specificity remained at 52.8% (95% CI: 35.7–69.2). When comparing the concordance of the ABVS with the gold standard (conventional handheld ultrasound), Cohen’s Kappa value as an estimation of the inter-rater reliability was κ = 0.37, indicating fair agreement. In conclusion, the ABVS must still be regarded as an experimental technique for breast ultrasound, which definitely needs to undergo further evaluation studies.

10 June 2022 in Journal of Clinical Oncology
Verified
Journal Article
Closed access
APAndré Pfob
André Pfob
Christopher GibbonsChristopher Gibbons
Christopher Gibbons
GRGeraldine Rauch
Geraldine Rauch
BTBettina Thomas
Bettina Thomas
BSBenedikt Schaefgen
Benedikt Schaefgen
JHJörg Heil
Jörg Heil
PURPOSE: Neoadjuvant systemic treatment (NST) elicits a pathologic complete response in 40%-70% of women with breast cancer. These patients may not need surgery as all local tumor has already been eradicated by NST. However, nonsurgical approaches, including imaging or vacuum-assisted biopsy (VAB), were not able to accurately identify patients without residual cancer in the breast or axilla. We evaluated the feasibility of a machine learning algorithm (intelligent VAB) to identify exceptional responders to NST.METHODS: We trained, tested, and validated a machine learning algorithm using patient, imaging, tumor, and VAB variables to detect residual cancer after NST (ypT+ or in situ or ypN+) before surgery. We used data from 318 women with cT1-3, cN0 or +, human epidermal growth factor receptor 2–positive, triple-negative, or high-proliferative Luminal B–like breast cancer who underwent VAB before surgery (ClinicalTrials.gov identifier: NCT02948764 , RESPONDER trial). We used 10-fold cross-validation to train and test the algorithm, which was then externally validated using data of an independent trial (ClinicalTrials.gov identifier: NCT02575612 ). We compared findings with the histopathologic evaluation of the surgical specimen. We considered false-negative rate (FNR) and specificity to be the main outcomes.RESULTS: In the development set (n = 318) and external validation set (n = 45), the intelligent VAB showed an FNR of 0.0%-5.2%, a specificity of 37.5%-40.0%, and an area under the receiver operating characteristic curve of 0.91-0.92 to detect residual cancer (ypT+ or in situ or ypN+) after NST. Spiegelhalter's Z confirmed a well-calibrated model ( z score –0.746, P = .228). FNR of the intelligent VAB was lower compared with imaging after NST, VAB alone, or combinations of both.CONCLUSION: An intelligent VAB algorithm can reliably exclude residual cancer after NST. The omission of breast and axillary surgery for these exceptional responders may be evaluated in future trials.

19 December 2012 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
SWSebastian Wojcinski
Sebastian Wojcinski
JDJennifer Dupont
Jennifer Dupont
WSWerner Schmidt
Werner Schmidt
MCMichael Cassel
Michael Cassel
PHPeter Hillemanns
Peter Hillemanns
To determine the general appearance of normal axillary lymph nodes (LNs) in real-time tissue sonoelastography and to explore the method′s potential value in the prediction of LN metastases.

12 November 2013 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
SWSebastian Wojcinski
Sebastian Wojcinski
SGSamuel Gyapong
Samuel Gyapong
AFAndré Farrokh
André Farrokh
PSPhilipp Soergel
Philipp Soergel
PHPeter Hillemanns
Peter Hillemanns
FDFriedrich Degenhardt
Friedrich Degenhardt
Automated whole breast ultrasound scanners of the latest generation have reached a level of comfortable application and high quality volume acquisition. Nevertheless, there is a lack of data concerning this technology. We investigated the diagnostic performance and inter-observer concordance of the Automated Breast Volume Scanner (ABVS) ACUSON S2000™ and questioned its implications in breast cancer diagnostics.