Fred H. M. Wittkampf

Fred H. M. Wittkampf

Auto-generated profile, based on publicly available information

Fred H. M. Wittkampf

Division Heart and Lungs, Department of Cardiology, University Medical Center (M.H.A.G., V.J.H.M.v.D., K.N., H.v.W., P.A.F.D., F.H.M.W., P.L., R.v.E.).

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2021 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
PDF file
HNHiroshi Nakagawa
Hiroshi Nakagawa
AIAtsushi Ikeda
Atsushi Ikeda
TSTushar Sharma
Tushar Sharma
AGAssaf Govari
Assaf Govari
JAJohn Ashton
John Ashton
WJWarren M. Jackman
Warren M. Jackman
Background: With short radiofrequency (RF) applications, tissue temperature continues to rise after RF termination (thermal latency), which may result in lesion growth after RF termination. The purpose was to compare in vivo tissue temperature profile (thermal latency), lesion size, and the incidence of steam pop and thrombus between RF ablation with very high power–very short RF (90 W/4 s), high power–short RF (50 W/10 s), and moderate power–moderate RF (30 W/30 s) in a canine thigh muscle preparation and beating heart. Methods: In the thigh muscle preparation (5 dogs), a 3.5-mm ablation electrode with 66 or 56 small irrigation holes (QDOT-Micro or ThermoCoolSmartTouch-SF, respectively) was held perpendicular or parallel to the muscle at 10 g or 30 g contact force. Total of 120 RFs were delivered at 90 W/4 s (QDOT catheter), 50 W/10 s, or 30 W/30 s (SF catheter). Electrode temperature, electrode-tissue interface temperature, and tissue temperatures at 3- and 7-mm depths were measured. In 6 closed-chest dogs, total of 72 RFs were delivered in the ventricle at 90 W/4 s, 50 W/10 s, or 30 W/30 s. Results: In the thigh muscle preparation, tissue temperatures and lesion size (depth, diameter, and volume) were the lowest/smallest for RFs at 90 W/4 s, followed by 50 W/10 s, and the greatest for 30 W/30 s. Thermal latency (Δtemperature and duration) was the greatest for RFs at 90 W/4 s, followed by 50 W/10 s, and the smallest for 30 W/30 s ( P <0.01). Effective tissue heating (area under the curve ≥50 °C at 3-mm depth) was observed after RF termination in 88.0±7.6% with 90 W/4 s, 57.7±14.6% with 50 W/10 s, and only 31.9±8.5% with 30 W/30 s ( P <0.01). In beating hearts, lesion size was also the smallest with 90 W/4 s and the greatest with 30 W/30 s RFs. Increasing contact force significantly increased lesion depth in all 3 groups. There was no significant difference in the incidence of steam pop or thrombus between 3 groups. Conclusions: Tissue temperatures and lesion size (depth, diameter, and volume) were the lowest/smallest for RF applications at 90 W/4 s, followed by 50 W/10 s, and the greatest for 30 W/30 s. The greater thermal latency for 90 W/4 s RF applications suggests that a significant portion of lesion is created after RF termination due to conductive tissue heating.

1 August 2018 in JACC: Clinical Electrophysiology
Verified
Journal Article
Closed access
FWFred H.M. Wittkampf
Fred H.M. Wittkampf
RERené van Es
René van Es
KNKars Neven
Kars Neven

31 May 2012 in EP Europace
Verified
Journal Article
Open access
PDF file
BPBastiaan C. du Pré
Bastiaan C. du Pré
VDVincent J. van Driel
Vincent J. van Driel
HWHarry van Wessel
Harry van Wessel
PLPeter Loh
Peter Loh
PDPieter A. Doevendans
Pieter A. Doevendans
AVAryan Vink
Aryan Vink
Radiofrequency catheter ablation is a successful treatment for cardiac arrhythmias, but may lead to major complications such as permanent coronary damage. Irreversible electroporation (IRE) is a new non-thermal ablation modality, but its effect on coronary arteries is still unknown. In a porcine model, epicardial IRE lesions were created at the base of the left ventricle in four hearts (group A) and directly on the left anterior descending artery (LAD) in five hearts (group B). After 3 weeks, coronary arteries inside IRE lesions and in apparently undamaged myocardium next to the lesions were (immuno-)histologically studied. Two untreated hearts served as controls. Coronary damage was defined as intimal hyperplasia. Left anterior descending artery angiograms were obtained before ablation, directly after ablation, and before termination in group B. In group A, 103 arterial branches were studied. Of these, 5 of 56 arterial branches inside lesions and 1 of 47 outside lesions showed intimal hyperplasia, but all had <50% area stenosis. Targeted LADs (group B) did not reveal intimal hyperplasia and angiograms showed no signs of stenosis. Expression of connective tissue growth factor was observed in the scar tissue, but not in the fibrotic tissue directly around the arteries, confirming that the arteries are indeed spared from tissue damage and remodelling. Coronary arteries remain free of clinically relevant damage 3 weeks after epicardial IRE ablation, even amid very large myocardial lesions. This suggests that IRE ablation can be applied safely near or even on coronary arteries. With IRE ablation, arterial blood flow does not appear to affect lesion formation.

8 March 2011 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PDF file
FWFred H. Wittkampf
Fred H. Wittkampf
VDVincent J. VAN Driel
Vincent J. VAN Driel
HWHarry VAN Wessel
Harry VAN Wessel
AVAryan Vink
Aryan Vink
IHIrene E. Hof
Irene E. Hof
PLPeter Loh
Peter Loh

1 June 2012 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
PDF file
FWFred H.M. Wittkampf
Fred H.M. Wittkampf
VDVincent J. van Driel
Vincent J. van Driel
HWHarry van Wessel
Harry van Wessel
KNKars G.E.J. Neven
Kars G.E.J. Neven
PGPaul F. Gründeman
Paul F. Gründeman
PDPieter A. Doevendans
Pieter A. Doevendans
Background—Recently, we demonstrated the feasibility and safety of circular electroporation ablation in porcine pulmonary vein ostia, but the relationship between the magnitude of the application and lesion dimensions is still unknown. Methods and Results—An in vivo porcine study was performed on left ventricular epicardium submerged under 10 mm of blood, using devices that mimic a 20-mm-diameter 7F circular ablation catheter. Model D contained 10 separate electrodes, whereas model M consisted of 1 circular electrode. Ablations were performed at 50, 100, and 200 J with model D and at 100 J with model M. Lesion dimensions were measured after 3-week survival. All applications resulted in smooth voltage waveforms demonstrating the absence of vapor globe formation, arcing, and a pressure wave. Applications up to 100 J with model D resulted in separate lesions under the electrodes. At 200 J, continuous deep circular lesions were created despite the use of separate electrodes. There was a significant relationship between applied current and median lesion depth, with a slope of 0.17 mm/A. At 100 J, there was no difference in lesion depth or width between models D and M. The electrodes and ablation site directly after ablation showed no signs of thermal damage. Conclusions—In an epicardial porcine model with blood around the application site, continuous circular lesions, deep enough for electric pulmonary vein isolation, were created with a single circular 200-J application. Lesions were continuous despite the use of separate electrodes. Lesion depth increased with the magnitude of the application.

1 October 2020 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
PDF file
Peter LohPeter Loh
Peter Loh
RERené van Es
René van Es
MGMarijn H.A. Groen
Marijn H.A. Groen
KNKars Neven
Kars Neven
WKWil Kassenberg
Wil Kassenberg
PDP. A. Doevendans
P. A. Doevendans
Background - Irreversible electroporation (IRE) is a promising new non-thermal ablation technology for pulmonary vein (PV) isolation in patients with atrial fibrillation (AF). Experimental data suggest that IRE ablation produces large enough lesions without the risk of PV stenosis, artery, nerve or esophageal damage. This study aimed to investigate the feasibility and safety of single pulse IRE PV isolation in patients with AF. Methods - Ten patients with symptomatic paroxysmal or persistent AF underwent single pulse IRE PV isolation under general anesthesia. Three-dimensional reconstruction and electroanatomical voltage mapping (EnSite PrecisionTM, Abbott) of left atrium and PVs were performed using a conventional circular mapping catheter. PV isolation was performed by delivering non-arcing, non-barotraumatic 6 ms, 200 J direct current IRE applications via a custom non-deflectable 14-polar circular IRE ablation catheter with a variable hoop diameter (16-27 mm). A deflectable sheath (AgilisTM, Abbott) was used to maneuver the ablation catheter. A minimum of two IRE applications with slightly different catheter positions were delivered per vein to achieve circular tissue contact, even if PV potentials were abolished after the first application. Bidirectional PV isolation was confirmed with the circular mapping catheter and a post ablation voltage map. After a 30-minute waiting period, adenosine testing (30 mg) was used to reveal dormant PV conduction. Results - All 40 PVs could be successfully isolated with a mean of 2.4±0.4 IRE applications per PV. Mean delivered peak voltage and peak current were 2154 ± 59 V and 33.9 ± 1.6 A, respectively. No PV reconnections occurred during the waiting period and adenosine testing. No periprocedural complications were observed. Conclusions - In the 10 patients of this first-in-human study, acute bidirectional electrical PV isolation could be achieved safely by single pulse IRE ablation.