1 July 2021 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
PDF file
HNHiroshi Nakagawa
Hiroshi Nakagawa
AIAtsushi Ikeda
Atsushi Ikeda
TSTushar Sharma
Tushar Sharma
AGAssaf Govari
Assaf Govari
JAJohn Ashton
John Ashton
WJWarren M. Jackman
Warren M. Jackman
Background: With short radiofrequency (RF) applications, tissue temperature continues to rise after RF termination (thermal latency), which may result in lesion growth after RF termination. The purpose was to compare in vivo tissue temperature profile (thermal latency), lesion size, and the incidence of steam pop and thrombus between RF ablation with very high power–very short RF (90 W/4 s), high power–short RF (50 W/10 s), and moderate power–moderate RF (30 W/30 s) in a canine thigh muscle preparation and beating heart. Methods: In the thigh muscle preparation (5 dogs), a 3.5-mm ablation electrode with 66 or 56 small irrigation holes (QDOT-Micro or ThermoCoolSmartTouch-SF, respectively) was held perpendicular or parallel to the muscle at 10 g or 30 g contact force. Total of 120 RFs were delivered at 90 W/4 s (QDOT catheter), 50 W/10 s, or 30 W/30 s (SF catheter). Electrode temperature, electrode-tissue interface temperature, and tissue temperatures at 3- and 7-mm depths were measured. In 6 closed-chest dogs, total of 72 RFs were delivered in the ventricle at 90 W/4 s, 50 W/10 s, or 30 W/30 s. Results: In the thigh muscle preparation, tissue temperatures and lesion size (depth, diameter, and volume) were the lowest/smallest for RFs at 90 W/4 s, followed by 50 W/10 s, and the greatest for 30 W/30 s. Thermal latency (Δtemperature and duration) was the greatest for RFs at 90 W/4 s, followed by 50 W/10 s, and the smallest for 30 W/30 s ( P <0.01). Effective tissue heating (area under the curve ≥50 °C at 3-mm depth) was observed after RF termination in 88.0±7.6% with 90 W/4 s, 57.7±14.6% with 50 W/10 s, and only 31.9±8.5% with 30 W/30 s ( P <0.01). In beating hearts, lesion size was also the smallest with 90 W/4 s and the greatest with 30 W/30 s RFs. Increasing contact force significantly increased lesion depth in all 3 groups. There was no significant difference in the incidence of steam pop or thrombus between 3 groups. Conclusions: Tissue temperatures and lesion size (depth, diameter, and volume) were the lowest/smallest for RF applications at 90 W/4 s, followed by 50 W/10 s, and the greatest for 30 W/30 s. The greater thermal latency for 90 W/4 s RF applications suggests that a significant portion of lesion is created after RF termination due to conductive tissue heating.

1 January 2024 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
HNHiroshi Nakagawa
Hiroshi Nakagawa
QCQuim Castellvi
Quim Castellvi
RIRobert Evans Neal II
Robert Evans Neal II
SGSteven Girouard
Steven Girouard
JLJacob Laughner
Jacob Laughner
OWOussama M. Wazni
Oussama M. Wazni
Background: Effects of contact force (CF) on lesion formation during pulsed field ablation (PFA) have not been well validated. The purpose of this study was to determine the relationship between average CF and lesion size during PFA using a swine-beating heart model. Methods: A 7F catheter with a 3.5-mm ablation electrode and CF sensor (TactiCath SE, Abbott) was connected to a PFA system (CENTAURI, Galvanize Therapeutics). In 5 closed-chest swine, biphasic PFA current was delivered between the ablation electrode and a skin patch at 40 separate sites in right ventricle (28 Amp) and 55 separate sites in left ventricle (35 Amp) with 4 different levels of CF: (1) low (CF range of 4–13 g; median, 9.5 g); (2) moderate (15–30 g; median, 21.5 g); (3) high (34–55 g; median, 40 g); and (4) no electrode contact, 2 mm away from the endocardium. Swine were sacrificed at 2 hours after ablation, and lesion size was measured using triphenyl tetrazolium chloride staining. In 1 additional swine, COX (cytochrome c oxidase) staining was performed to examine mitochondrial activity to delineate reversible and irreversible lesion boundaries. Histological examination was performed with hematoxylin and eosin and Masson trichrome staining. Results: Ablation lesions were well demarcated with triphenyl tetrazolium chloride staining, showing (1) a dark central zone (contraction band necrosis and hemorrhage); (2) a pale zone (no mitochondrial activity and nuclear pyknosis, indicating apoptosis zone); and a hyperstained zone by triphenyl tetrazolium chloride and COX staining (unaffected normal myocardium with preserved mitochondrial activity, consistent with reversible zone). At constant PFA current intensity, lesion depth increased significantly with increasing CF. There were no detectable lesions resulting from ablation without electrode contact. Conclusions: Acute PFA ventricular lesions show irreversible and reversible lesion boundaries by triphenyl tetrazolium chloride staining. Electrode-tissue contact is required for effective lesion formation during PFA. At the same PFA dose, lesion depth increases significantly with increasing CF.

23 May 2023 in Circulation
Verified
Journal Article
Open access
KNKoonlawee Nademanee
Koonlawee Nademanee
FCFa-Po Chung
Fa-Po Chung
FSFrederic Sacher
Frederic Sacher
ANAkihiko Nogami
Akihiko Nogami
HNHiroshi Nakagawa
Hiroshi Nakagawa
MHMichel Haïssaguerre
Michel Haïssaguerre
Background: Treatment options for high-risk Brugada syndrome (BrS) with recurrent ventricular fibrillation (VF) are limited. Catheter ablation is increasingly performed but a large study with long-term outcome data is lacking. We report the results of the multicenter, international BRAVO (Brugada Ablation of VF Substrate Ongoing Registry) for treatment of high-risk symptomatic BrS. Methods: We enrolled 159 patients (median age 42 years; 156 male) with BrS and spontaneous VF in BRAVO; 43 (27%) of them had BrS and early repolarization pattern. All but 5 had an implantable cardioverter-defibrillator for cardiac arrest (n=125) or syncope (n=34). A total of 140 (88%) had experienced numerous implantable cardioverter-defibrillator shocks for spontaneous VF before ablation. All patients underwent a percutaneous epicardial substrate ablation with electroanatomical mapping except for 8 who underwent open-thoracotomy ablation. Results: In all patients, VF/BrS substrates were recorded in the epicardial surface of the right ventricular outflow tract; 45 (29%) patients also had an arrhythmic substrate in the inferior right ventricular epicardium and 3 in the posterior left ventricular epicardium. After a single ablation procedure, 128 of 159 (81%) patients remained free of VF recurrence; this number increased to 153 (96%) after a repeated procedure (mean 1.2±0.5 procedures; median=1), with a mean follow-up period of 48±29 months from the last ablation. VF burden and frequency of shocks decreased significantly from 1.1±2.1 per month before ablation to 0.003±0.14 per month after the last ablation ( P <0.0001). The Kaplan-Meier VF-free survival beyond 5 years after the last ablation was 95%. The only variable associated with a VF-free outcome in multivariable analysis was normalization of the type 1 Brugada ECG, both with and without sodium-channel blockade, after the ablation (hazard ratio, 0.078 [95% CI, 0.008 to 0.753]; P =0.0274). There were no arrhythmic or cardiac deaths. Complications included hemopericardium in 4 (2.5%) patients. Conclusions: Ablation treatment is safe and highly effective in preventing VF recurrence in high-risk BrS. Prospective studies are needed to determine whether it can be an alternative treatment to implantable cardioverter-defibrillator implantation for selected patients with BrS. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04420078.

1 August 2024 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
HNHiroshi Nakagawa
Hiroshi Nakagawa
SFSalman Farshchi-Heydari
Salman Farshchi-Heydari
JMJennifer Maffre
Jennifer Maffre
TSTushar Sharma
Tushar Sharma
AGAssaf Govari
Assaf Govari
OWOussama M. Wazni
Oussama M. Wazni
BACKGROUND: During pulsed field ablation (PFA), relationships between ablation parameters (contact force [CF], number of burst pulses, impedance decrease, and electrode temperature) and lesion size in beating hearts have not been well validated. METHODS: A 7.5F-catheter with a 3.5-mm ablation electrode and CF sensor (ThermoCool SmartTouch SF-Dual-Energy, Biosense Webster, Inc, Irwindale, CA) was connected to a PFA system (TRUPULSE2, Biosense Webster, Inc). In 11 closed-chest swine, biphasic PFA current was delivered between the ablation electrode and the skin patch at 219 sites in left ventricle and right ventricle using 12, 18, and 24 burst pulses with 4 different levels of CF: (1) low (n=57; CF, 4–15 g ; median, 10 g ); (2) moderate (n=60; CF, 16–30 g ; median, 22.5 g ); (3) high (n=68; CF, 32–65 g ; median, 40 g ); and (4) no electrode contact (n=34), 2 mm away from the endocardium. Swine were euthanized 2 hours after ablation, and lesion size was measured using triphenyl tetrazolium chloride staining. RESULTS: All PFA lesions with electrode-myocardium contact were well demarcated with triphenyl tetrazolium chloride staining, demonstrating (1) pale central zone (contraction band necrosis with minimal coagulation necrosis), (2) dark brown zone (contraction band necrosis with hemorrhage), and (3) hyperstained red zone by triphenyl tetrazolium chloride (unaffected normal myocardium with preserved mitochondrial activity, consistent with reversible zone). Lesion depth increased significantly with increasing CF and the number of PFA burst pulses. An exponential/logarithmic formula combined with CF and the number of PFA burst pulses correlated lesion depth with high accuracy: R=0.809, P <0.0001, ±1.0-mm accuracy in 128 of 163 (79%) lesions, and ±1.5-mm accuracy in 153 of 163 (94%) lesions. Impedance decrease and electrode temperature were poor predictors of lesion size. There were no detectable lesions resulting from ablation without electrode contact. CONCLUSIONS: Acute PFA ventricular lesions demonstrate irreversible and reversible lesion boundaries. Electrode-tissue contact is required for effective lesion formation. Lesion depth increases significantly with increasing CF and PFA burst pulses. A new exponential/logarithmic formula combined with CF and the number of PFA burst pulses correlates lesion depth with high accuracy.

1 April 2024 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Open access
LBLuigi Di Biase
Luigi Di Biase
JMJacopo Marazzato
Jacopo Marazzato
AGAssaf Govari
Assaf Govari
AAAndreas Altman
Andreas Altman
CBChristopher Beeckler
Christopher Beeckler
HNHiroshi Nakagawa
Hiroshi Nakagawa
BACKGROUND: The effect of contact force (CF) on lesion formation is not clear during pulsed field ablation (PFA). The aim of this study was to evaluate the impact of CF, PFA, and their interplay through the PFA index (PF index) formula on the ventricular lesion size in swine. METHODS: PFA was delivered through the CF-sensing OMNYPULSE catheter. Predefined PFA applications (×3, ×6, ×9, and ×12) were delivered maintaining low (5–25 g), high (26–50 g), and very high (51–80 g) CFs. First, PFA lesions were evaluated on necropsy in 11 swine to investigate the impact of CF/PFA—and their integration in the PF index equation—on lesion size (study characterization). Then, 3 different PF index thresholds—300, 450, and 600—were tested in 6 swine to appraise the PF index accuracy to predict the ventricular lesion depth (study validation). RESULTS: In the study characterization data set, 111 PFA lesions were analyzed. CF was 32±17 g. The average lesion depth and width were 3.5±1.2 and 12.0±3.5 mm, respectively. More than CF and PFA dose alone, it was their combined effect to impact lesion depth through an asymptotically increasing relationship. Likewise, not only was the PF index related to lesion depth in the study validation data set (r 2 =0.66; P <0.001) but it also provided a prediction accuracy of the observed depth of ±2 mm in 69/73 lesions (95%). CONCLUSIONS: CF and PFA applications play a key role in lesion formation during PFA. Further studies are required to evaluate the best PFA ablation settings to achieve transmural lesions.

1 June 2024 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
AYArwa Younis
Arwa Younis
PSPasquale Santangeli
Pasquale Santangeli
KGKara Garrott
Kara Garrott
EBEric Buck
Eric Buck
CTChadi Tabaja
Chadi Tabaja
OWOussama M. Wazni
Oussama M. Wazni
BACKGROUND: Conventional focal radiofrequency catheters may be modified to enable multiple energy modalities (radiofrequency or pulsed field [PF]) with the benefit of contact force (CF) feedback, providing greater flexibility in the treatment of arrhythmias. Information on the impact of CF on lesion formation in PF ablations remains limited. METHODS: An in vivo study was performed with 8 swine using an investigational dual-energy CF focal catheter with local impedance. Experiment I: To evaluate atrial lesion formation, contiguity, and width, a point-by-point approach was used to create an intercaval line. The distance between the points was prespecified at 4±1 mm. Half of the line was created with radiofrequency energy, whereas the other half utilized PF (single 2.0 kV application with a proprietary waveform). Experiment II: To evaluate single application lesion dimensions with a proprietary waveform, discrete ventricular lesions were performed with PFA (single 2.0 kV application) with targeted levels of CF: low, 5 to 15 g; medium, 20 to 30 g; and high, 35 to 45 g. Following 1 week of survival, animals underwent endocardial/epicardial remapping, and euthanasia to enable histopathologic examination. RESULTS: Experiment I: Both energy modalities resulted in a complete intercaval line of transmural ablation. PF resulted in significantly wider lines than radiofrequency: minimum width, 14.9±2.3 versus 5.0±1.6 mm; maximum width, 21.8±3.4 versus 7.3±2.1 mm, respectively; P <0.01 for each. Histology confirmed transmural lesions with both modalities. Experiment II: With PF, lesion depth, width, and volume were larger with higher degrees of CF (depth: r=0.82, P <0.001; width: r=0.26, P =0.052; and volume: r=0.55, P <0.001), with depth increasing at a faster rate than width. The mean depths were as follows: low (n=17), 4.3±1.0 mm; medium (n=26), 6.4±1.2 mm; and high (n=14), 9.1±1.4 mm. CONCLUSIONS: Using the same focal point CF-sensing catheter, a novel PF ablation waveform with a single application resulted in transmural atrial lesions that were significantly wider than radiofrequency. Lesion depth showed a significant positive correlation with CF with depths of 6.4 mm at moderate CF.