Themistoklis D. Kefalas

Themistoklis D. Kefalas

Auto-generated profile, based on publicly available information

Themistoklis D. Kefalas

School of Electrical and Computer Engineering, National Technical University of Athens, 15780 Athens, Greece

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2009 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
TKThemistoklis D. Kefalas
Themistoklis D. Kefalas
AKAntonios G. Kladas
Antonios G. Kladas
The losses in European Union distribution transformers are estimated at about 33 TW ·h/year, whereas reactive power and harmonic losses add a further 5 TW ·h/year. The reduction of distribution transformer no-load loss is particularly important as the ratio of no-load to load losses is nearly three. In this paper, the no-load operation of wound-core transformers under sinusoidal and distorted supply-voltage conditions is investigated. For that purpose, a 2-D nonlinear transient finite-element analysis taking into account hysteresis has been developed. The hysteresis model is based on a modified Jiles-Atherton representation, and the proposed analysis is compared to experimental data.

16 August 2013 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
TKThemistoklis D. Kefalas
Themistoklis D. Kefalas
AKAntonios G. Kladas
Antonios G. Kladas
This paper concerns the thermal investigation of a surface-mounted permanent-magnet synchronous motor designed for high-temperature aerospace actuation applications. A finite-element package was developed, enabling accurate 3-D transient thermal analysis by considering complex and unsymmetrical actuator housing configurations. Its validity was verified by measurements carried out at different duty cycles and operating conditions.

26 March 2007 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
EAEleftherios I. Amoiralis
Eleftherios I. Amoiralis
Pavlos GeorgilakisPavlos Georgilakis
Pavlos Georgilakis
TKThemistoklis D. Kefalas
Themistoklis D. Kefalas
MTMarina A. Tsili
Marina A. Tsili
AKAntonios G. Kladas
Antonios G. Kladas
The aim of the transformer design optimization is to define the dimensions of all the parts of the transformer, based on the given specification, using available materials economically in order to achieve lower cost, lower weight, reduced size, and better operating performance. In this paper, a hybrid artificial intelligence/numerical technique is proposed for the selection of winding material in power transformers. The technique uses decision trees and artificial neural networks for winding material classification, along with finite-element/boundary element modeling of the transformer for the calculation of the performance characteristics of each considered design. The efficiency and accuracy provided by the hybrid numerical model render it particularly suitable for use with optimization algorithms. The accuracy of this method is 96% (classification success rate for the winding material on an unknown test set), which makes it very efficient for industrial use

20 May 2008 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
TKThemistoklis D. Kefalas
Themistoklis D. Kefalas
Pavlos GeorgilakisPavlos Georgilakis
Pavlos Georgilakis
AKAntonios G. Kladas
Antonios G. Kladas
ASAthanassios T. Souflaris
Athanassios T. Souflaris
DPDimitris G. Paparigas
Dimitris G. Paparigas
This paper introduces a novel technique for iron loss minimization of wound core transformers. The proposed technique involves the evaluation of appropriate design variables of wound cores constructed by a combination of standard and high magnetization grade steel. The evaluation of the optimum design variables of the multiple grade lamination wound core is achieved by combining a permeability tensor finite-element model and simulated annealing with restarts.

30 June 2011 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
TKThemistoklis D. Kefalas
Themistoklis D. Kefalas
AKAntonios G. Kladas
Antonios G. Kladas
In recent years, researchers have proposed transformerless solutions for connecting renewable-energy power plants to the grid. Apart from lack of efficiency and increased cost and weight of the transformer, one of the reasons is the dc input current that causes transformer saturation. The purpose of this paper is the development of a finite-element computational tool that is going to aid transformer manufacturers in designing distribution transformers specifically for the renewable-energy market. It is based on a generalized macroscopic representation of electrical steels used in the transformer manufacturing industry that enables the accurate evaluation of electromagnetic field distribution of transformer cores under heavily saturated conditions. Its advantages over conventional formulations include numerical stability, numerical accuracy, and reduction of iterations of the Newton-Raphson method. An experimental verification of the proposed method is carried out.

19 January 2010 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
GLGeorge Loizos
George Loizos
TKThemistoklis D. Kefalas
Themistoklis D. Kefalas
AKAntonios G. Kladas
Antonios G. Kladas
ASAthanassios T. Souflaris
Athanassios T. Souflaris
This paper shows experimental results of longitudinal flux density and its harmonics at the limb, the yoke and the corner of a three-phase, Si-Fe, five-legged wound transformer core. Results show that the flux density is nonuniform in the cores and there is high level of third harmonic component. Moreover, the lower flux values in the outer cores have been assessed and the simultaneous time variation of the flux in both outer cores has been demonstrated by measurements while the peak magnetic flux density values have been compared to FEM analysis. These findings enable a better understanding of the magnetic behavior of five-legged wound transformer cores and their consideration is expected to achieve respective improvement of the design with respect to core losses and magnetostriction noise.