Yongwei Guo

Yongwei Guo

Auto-generated profile, based on publicly available information

Yongwei Guo

Eye Center, Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China; Zhejiang Provincial Key Laboratory of Ophthalmology, Hangzhou, China

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2020 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Open access
PDF file
LHLudwig M. Heindl
Ludwig M. Heindl
MTMarc Trester
Marc Trester
YGYongwei Guo
Yongwei Guo
FZFlorian Zwiener
Florian Zwiener
NSNarges Sadat
Narges Sadat
ARAlexander C. Rokohl
Alexander C. Rokohl
Purpose: To investigate anxiety and depression levels in prosthetic eye–wearing patients using standardized psychometric instruments, to define factors associated with these psychological diseases, and to identify a potential healthcare gap. Methods: A total of 295 prosthetic eye wearers were screened using the 7-item generalized anxiety disorder scale (GAD-7) and the 9-item patient health questionnaire (PHQ-9). Scores of GAD-7 and PHQ-9 were correlated with scores of general physical and mental health functioning, vision-related quality of life, appearance-related distress, appearance-related social function, and further biosocial factors. Results: Five patients (2%) had a pre-diagnosed anxiety disorder, and 20 patients (7%) had a pre-diagnosed depression. However, our screening revealed 26 patients (9%) with anxiety symptoms, 31 patients (11%) with depression symptoms, and 40 patients (14%) suffering from both anxiety and depression symptoms. This underdiagnosing for both anxiety and depression disorders was significant (p < 0.001, respectively). Higher GAD-7 scores were significantly associated with higher PHQ-9 scores, lower appearance-related social function, lower mental health functioning, and female gender (p ≤ 0.021, respectively). Higher PHQ-9 scores were significantly associated with lower physical and mental health functioning, higher educational degree, and non-traumatic eye loss (p ≤ 0.038, respectively). Conclusions: Anxiety and depression disorders seem to be underdiagnosed in prosthetic eye wearers and to have higher incidence compared with the general population. Therefore, a psychometric screening should be routinely implemented in the clinical care. For a successful long-term rehabilitation, integrated care by a multidisciplinary team including ophthalmic plastic surgeons, ophthalmologists, ocularists, general practitioners, and psychologists is essential.

1 March 2020 in Plastic and Reconstructive Surgery
Verified
Journal Article
Closed access
YGYongwei Guo
Yongwei Guo
FSFriederike Schaub
Friederike Schaub
JMJoel M. Mor
Joel M. Mor
RJRenbing Jia
Renbing Jia
KKKonrad R. Koch
Konrad R. Koch
LHLudwig M. Heindl
Ludwig M. Heindl
Background: The three-dimensional surface imaging system is becoming more common in plastic surgeries. However, few studies have assessed three-dimensional periocular structures and surgical outcomes. This study aimed to propose a standardized three-dimensional anthropometric protocol for the periocular region, investigate its precision and accuracy, and determine the three-dimensional periocular anthropometric norms for young Caucasians. Methods: Thirty-nine healthy young Caucasians (78 eyes) were enrolled. Three-dimensional facial images were obtained with a VECTRA M3 stereophotogrammetry device. Thirty-eight measurements in periocular regions were obtained from these images. Every subject underwent facial surface capture twice to evaluate its precision. A paper ruler was applied to assess its accuracy. Results: Sixty-three percent of measurements in linear distances, curvatures, angles, and indices were found to reach a statistically significant difference between sexes (p ≤ 0.05, respectively). Across all measurements, the average mean absolute difference was 0.29 mm in linear dimensions, 0.56 mm in curvatures, 1.67 degrees in angles, and 0.02 in indices. In relative error of magnitude, 18 percent of the measurements were determined excellent, 51 percent very good, 31 percent good, and none moderate. The mean value of the paper-ruler scale was 10.01 ± 0.05 mm, the mean absolute difference value 0.02 mm, and the relative error of magnitude 0.17 percent. Conclusions: This is the first study to propose a detailed and standardized three-dimensional anthropometric protocol for the periocular region and confirm its high precision and accuracy. The results provided novel metric data concerning young Caucasian periocular anthropometry and determined the variability between sexes.

12 August 2019 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Closed access
PDF file
YGYongwei Guo
Yongwei Guo
ARAlexander C. Rokohl
Alexander C. Rokohl
FSFriederike Schaub
Friederike Schaub
XHXiaoyi Hou
Xiaoyi Hou
JLJinhua Liu
Jinhua Liu
LHLudwig M. Heindl
Ludwig M. Heindl

20 April 2019 in Journal of Biomaterials Applications
Verified
Journal Article
Closed access
PDF file
NZNongping Zhong
Nongping Zhong
TDTao Dong
Tao Dong
ZCZhongchun Chen
Zhongchun Chen
YGYongwei Guo
Yongwei Guo
ZSZhengzhong Shao
Zhengzhong Shao
XZXia Zhao
Xia Zhao
The functional epithelial regeneration is important for repairing tracheal defects. However, the potential of 3D-printed SF-based scaffolds for tracheal epithelial regeneration is still unknown. In this study, we developed a novel silk fibroin-based scaffold prepared by 3D printing of silk fibroin/hydroxypropyl methyl cellulose (SF/HPMC) thixotropic hydrogel and evaluated the tracheal epithelium proliferation on this scaffold in vitro. Combined with the freeze-dried technology, the 3D-printed SF/HPMC scaffolds had porous structures in the printed bars. After evaluation of their pore sizes, porosities, water contents and mechanical properties, the scaffolds were co-cultured with the normal human bronchial epithelial cell line (BEAS-2B) for seven days. We detected the BEAS-2B cells proliferation on the scaffolds using a CCK-8 assay, determined their mucin secretion and intercellular tight junction formation by immunofluorescence, as well as observed their cell viability and morphology by live/dead staining and scanning electronic microscopy. The results showed that the SF/HPMC scaffolds had good porosity, water content and mechanical properties. In addition, the BEAS-2B cells proliferated well on SF/HPMC scaffolds, during the seven-day co-culture, with high viability, mucin expression, and intercellular tight junction formation. In summary, these results demonstrated that the BEAS-2B cells could attach and proliferate on the 3D-printed SF/HPMC scaffolds, which were expected to have potential for facilitating tracheal epithelial regeneration.

1 July 2020 in The Ocular Surface
Verified
Journal Article
Closed access
ARAlexander Christopher Rokohl
Alexander Christopher Rokohl
MTMarc Trester
Marc Trester
YGYongwei Guo
Yongwei Guo
WAWerner Adler
Werner Adler
VJViktoria K. Jaeger
Viktoria K. Jaeger
LHLudwig M. Heindl
Ludwig M. Heindl

10 October 2013 in Gene Therapy
Verified
Journal Article
Open access
PDF file
WQW Qi
W Qi
DDD Ding
D Ding
HZH Zhu
H Zhu
DLD Lu
D Lu
YWY Wang
Y Wang
YGY Guo
Y Guo
The use of small-interfering RNA (siRNA) has great potential for the development of drugs designed to knock down the expression of damage- or disease-causing genes. However, because of the high molecular weight and negative charge of siRNA, it is restricted from crossing the blood–cochlear barrier, which limits the concentration and size of molecules that are able to gain access to cells of the inner ear. Intratympanic approaches, which deliver siRNA to the middle ear, rely on permeation through the round window for access to the structures of the inner ear. We developed an innovative siRNA delivery recombination protein, TAT double-stranded RNA-binding domains (TAT-DRBDs), which can transfect Cy3-labeled siRNA into cells of the inner ear, including the inner and outer hair cells, crista ampullaris, macula utriculi and macula sacculi, through intact round-window permeation in the chinchilla in vivo, and there were no apparent morphological damages for the time of observation. We also found that Cy3-labeled siRNA could directly enter spiral ganglion neurons and the epithelium of the stria vascularis independently; however, the mechanism is unknown. Therefore, as a non-viral vector, TAT-DRBD is a good candidate for the delivery of double-stranded siRNAs for treating various inner ear ailments and preservation of hearing function.