A. A. Akovantseva

A. A. Akovantseva

Auto-generated profile, based on publicly available information

A. A. Akovantseva

Semenov Federal Research Center for Chemical Physics, Russian Academy of Sciences, Moscow, Russia

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 November 2017 in RSC Advances
Verified
Journal Article
Open access
PDF file
NVNatalia Voskoboynikova
Natalia Voskoboynikova
WMW. Mosslehy
W. Mosslehy
ACA. Colbasevici
A. Colbasevici
TIT. T. Ismagulova
T. T. Ismagulova
DBDmitry Bagrov
Dmitry Bagrov
HSHeinz-Jürgen Steinhoff
Heinz-Jürgen Steinhoff
The styrene–maleic acid (SMA) copolymers enable a detergent-free extraction of membrane proteins from lipid bilayers yielding stable water-soluble nanocontainers with lipid-encased proteins. Here, we demonstrate the ability of the SMA copolymer to extract a complex of interacting membrane proteins from proteoliposomes, namely the archaeal sensory rhodopsin II from Natronomonas pharaonis, NpSRII, in complex with its transducer, NpHtrII. The NpSRII/NpHtrII complexes retained their structural integrity within SMA lipid particles as revealed by diverse biophysical techniques. Pulse electron paramagnetic resonance data showed the SMA-encased NpSRII/NpHtrII complexes as native-like 2 : 2 dimers with a distance between NpSRII sites 159 according to the “V”-shaped conformation found in a crystal structure.

1 January 2022 in Russian Annals of Ophthalmology
Verified
Journal Article
Closed access
Sergei AvetisovSergei Avetisov
Sergei Avetisov
GOG.A. Osipyan
G.A. Osipyan
AAA.K. Abukerimova
A.K. Abukerimova
AAA.A. Akovantseva
A.A. Akovantseva
YEYuri Efremov
Yuri Efremov
PTPeter S. Timashev
Peter S. Timashev
В обзоре представлены результаты экспериментальных исследований биомеханических свойств роговицы. Селективная оценка отдельных структур роговицы (например, пограничных мембран) с помощью классических механических тестов в известной степени лимитирована из-за достаточно малой толщины этих структур и, как следствие, сложностей фиксации образца. В реальной практике перспективным остается использование более адаптированной для проведения подобных исследований атомно-силовой микроскопии, с одной стороны, исключающей необходимость механического захвата и удержания образца, а с другой — обеспечивающей возможность исследования различных участков последнего.

23 December 2025 in Russian Annals of Ophthalmology
Verified
Journal Article
Closed access
Sergei AvetisovSergei Avetisov
Sergei Avetisov
ADA.K. Dzamikhova
A.K. Dzamikhova
TST.YU. Shilova
T.YU. Shilova
AAA.A. Akovantseva
A.A. Akovantseva
SKSvetlana Kotova
Svetlana Kotova
IKI.V. Kozlova
I.V. Kozlova
One of the applied areas of biomechanics in ophthalmology involves studying changes in the fibrous coat of the eye in myopia. A series of studies using various methods has revealed alterations in the biomechanical properties of the sclera associated with progressive myopia due to structural and metabolic altering. However, corneal changes associated with myopia, and specifically those potentially influenced by the increase in axial length, remain less studied. Purpose. To study the biomechanical properties of the corneal stroma removed during small-incision lenticule extraction (SMILE) in myopia with varying axial length (AL). Material and methods. The study included 122 lenticules (stromal corneal fragments) obtained from patients aged 17—47 years during SMILE refractive correction for myopia. The preoperative spherical equivalent ranged from –0.75 to –13.25 D, and the AL varied between 22.64 and 29.05 mm. Baseline central corneal thickness (CCT) was 493.00—622.00 μm (mean 560.64±25.62 μm). Measurements were performed using a Bruker Bioscope Resolve atomic force microscope (Bruker, USA). Results. Selective assessment of the Young’s modulus (Y) for the anterior and posterior lenticule surfaces revealed comparable values (medians 51.00 and 53.60 kPa; minimum—maximum range 5.20—222.00 and 7.30—214.30 kPa, respectively). Analysis of the relationship between Y values and axial length showed a statistically significant but weak positive correlation for the anterior surface, in contrast to the posterior surface. A statistically significant inverse correlation was observed between Y and CCT: weak for the anterior surface and moderate for the posterior surface. Conclusion. Corneal fragments obtained during SMILE myopia correction provide a valuable model for biomechanical testing of the corneal stroma under conditions closely resembling in vivo physiology. The Young’s modulus values for the anterior and posterior lenticule surfaces were comparable and significantly correlated. The weak correlation between lenticule stiffness and axial length indirectly suggests minimal corneal biomechanical alterations associated with fibrous coat enlargement. The potential relationship between CCT and stromal biomechanics requires further investigation.

5 September 2024 in Urology Herald
Verified
Journal Article
Open access
PDF file
EPElena Olegovna Popova
Elena Olegovna Popova
STSergey Tkachev
Sergey Tkachev
Anastasia KarpenkoAnastasia Karpenko
Anastasia Karpenko
YLYu. A. Lee
Yu. A. Lee
PCPavel Chislov
Pavel Chislov
PTPeter S. Timashev
Peter S. Timashev
Despite advances in minimally invasive surgery, urolithiasis still recurs within the first five years after the first episode in more than 50% of patients. Researchers continue to search for new crystallisation inhibitors, metaphylaxis strategies and laser sources for stone destruction. Therefore, to achieve these goals, it is necessary to study kidney stones not only as the result of an isolated process of pathological biomineralisation in the human body, but also as a biogenic mineral or rock that obeys universal patterns and has certain properties. Consequently, kidney stones need to be studied using methods that are widely used in the geological sciences for the study of minerals, such as computed microtomography and petrological analysis. In this review, the properties of kidney stones studied using various research methods used in geosciences are discussed. These properties are also considered as new biomarkers of urolithiasis. This review discusses how new data from multimodal stone analysis can be used to develop personalised metaphylaxis and treatment strategies for all types of urolithiasis, including the most common idiopathic calcium-oxalate urolithiasis.

1 December 2025 in Russian Journal of Physical Chemistry B
Verified
Journal Article
Closed access
PDF file
ISIlya Shershnev
Ilya Shershnev
VKVladislav Kaplin
Vladislav Kaplin
AKA. S. Kopylov
A. S. Kopylov
NANadezhda Aksenova
Nadezhda Aksenova
AAA. A. Akovantseva
A. A. Akovantseva
ASA. B. Solovieva
A. B. Solovieva
Methacrylate derivatives of methoxypolyethylene glycol (mPEG) (5 kDa) have been synthesized in supercritical carbon dioxide (SC-CO2) using urethane formation reaction. The use of SC-CO2 has been shown to allow one to effectively run the reaction in two steps (with the preparation of an isocyanate derivative of mPEG in the first step and a methacrylate derivative in the second step) or combine the two steps into one. We have examined the effect of the reactant ratio and reaction conditions on the composition of the reaction products. Running the reaction in two steps has made it possible to obtain a methacrylate derivative of mPEG with a yield of up to 80%. The preparation of the isocyanate derivative of the polyester and the attachment of methacrylate residues were carried out at different parameters of SC-CO2: isocyanate groups were introduced under “harsh” conditions (65°C, 20–24 MPa), and methacrylate groups, under “mild” conditions (40°C, 12–13 MPa). The resultant monomers were polymerized to give three-dimensionally cross-linked systems based on both individual modified mPEG and its mixtures with methacrylated polylactide. In the future, such systems can be used as scaffolds for cell immobilization and fabrication of implants.