William J. Tom

William J. Tom

Auto-generated profile, based on publicly available information

William J. Tom

Department of Radiology, University of California, San Diego, La Jolla, CA, United States

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2008 in Optics Express
Verified
Journal Article
Closed access
PDF file
APAshwin B. Parthasarathy
Ashwin B. Parthasarathy
WTW. James Tom
W. James Tom
AGAshwini Gopal
Ashwini Gopal
XZXiaojing Zhang
Xiaojing Zhang
ADAndrew K Dunn
Andrew K Dunn
Laser Speckle Contrast Imaging (LSCI) is a minimally invasive full field optical technique used to generate blood flow maps with high spatial and temporal resolution. The lack of quantitative accuracy and the inability to predict flows in the presence of static scatterers such as an intact or thinned skull have been the primary limitation of LSCI. We present a new Multi-Exposure Speckle Imaging (MESI) instrument that has potential to obtain quantitative baseline flow measures. We show that the MESI instrument extends the range over which relative flow measurements are linear. We also present a new speckle model which can discriminate flows in the presence of static scatters. We show that in the presence of static scatterers the new model used along with the new MESI instrument can predict correlation times of flow consistently to within 10% of the value without static scatterers compared to an average deviation of more than 100% from the value without static scatterers using traditional LSCI. We also show that the new speckle model used with the MESI instrument can maintain the linearity of relative flow measurements in the presence of static scatterers.

16 May 2008 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
WTW. James Tom
W. James Tom
APAdrien Ponticorvo
Adrien Ponticorvo
ADAndrew K. Dunn
Andrew K. Dunn
Though laser speckle contrast imaging enables the measurement of scattering particle dynamics with high temporal resolution, the subsequent processing has previously been much slower. In prior studies, generating a laser speckle contrast image required about 1 s to process a raw image potentially collected in 10 ms or less. In this paper, novel algorithms are described which are demonstrated to convert 291 raw images per second to laser speckle contrast images and as many as 410 laser speckle contrast images per second to relative correlation time images. As long as image processing occurs during image acquisition, these algorithms render processing time irrelevant in most circumstances and enable real-time imaging of blood flow dynamics.

28 January 2020 in Frontiers in Oncology
Verified
Journal Article
Open access
SDShadi Daghighi
Shadi Daghighi
NBNaeim Bahrami
Naeim Bahrami
WTWilliam J. Tom
William J. Tom
NCNicholas Coley
Nicholas Coley
TSTyler M. Seibert
Tyler M. Seibert
CMCarrie R. McDonald
Carrie R. McDonald
Immunotherapy is increasingly used in the treatment of glioblastoma (GBM), with immune checkpoint therapy gaining in popularity given favorable outcomes achieved for other tumors. However, immune-mediated (IM)-pseudoprogression is common, remains poorly characterized, and renders conventional imaging of little utility when evaluating for treatment response. We present the case of a 64- year old man with GBM who developed pathologically proven IM-pseudoprogression after initiation of a checkpoint inhibitor, and who subsequently developed true tumor progression at a distant location. Based on both qualitative and quantitative analysis, we demonstrate that an advanced diffusion-weighted imaging (DWI) technique called restriction spectrum imaging (RSI) can differentiate IM-pseudoprogression from true progression even when conventional imaging, including standard DWI/apparent diffusion coefficient (ADC), is not informative. These data complement existing literature supporting the ability of RSI to estimate tumor cellularity, which may help to resolve complex diagnostic challenges such as the identification of IM-pseudoprogression.

1 January 2020 in Clinical Imaging
Verified
Journal Article
Closed access
WTW. James Tom
W. James Tom
XXXiangdong Xu
Xiangdong Xu
NVNoushin Vahdat
Noushin Vahdat
FCFiona Cassidy
Fiona Cassidy
LALejla Aganovic
Lejla Aganovic

8 February 2007
Verified
Conference Paper
Closed access
PDF file
APAdrien Ponticorvo
Adrien Ponticorvo
WTW. J. Tom
W. J. Tom
MAM. Aura
M. Aura
TJT. A. Jones
T. A. Jones
ADA. K. Dunn
A. K. Dunn
Endothelin-1 (ET-1) is a potent vasoconstrictor sometimes used in studies of cerebral ischemia. Its ability to create ischemic regions of various sizes with little additional damage has made it a popular tool in evaluating anti-stroke drugs. Despite its emergence in stroke models, it remains poorly characterized. Attempts to do this with Laser Doppler Flowmetry (LDF) or a histological analysis provide good temporal resolution or good spatial resolution respectively, but not both. An imaging modality that provides both temporal and spatial resolution would be able to better characterize the acute and chronic effects of ET-1 on cerebral blood flow. We have used laser speckle contrast imaging to study the effects of ET-1 after topical application on rats. We observed an immediate decrease in blood flow corresponding to the amount of ET-1 used. After the initial decrease, the blood flow slowly increases towards the baseline value with occasional vasospastic responses observed. Future studies involving multi-spectral reflectance imaging combined with the laser speckle contrast analysis would lead to a better understanding of the hemodynamic effects of ET-1.

21 May 2020
Verified
Conference Paper
Closed access
WTW. James Tom
W. James Tom
Purpose: In prior studies, aneurysms have been identified at the sites of intracranial arterial fenestrations suggesting that intracranial arterial fenestrations are a risk factor for aneurysm formation. However, prior studies being cross-sectional in design have been unable to quantify the risk of developing new aneurysms at arterial fenestrations. Materials and Methods: We