18 April 2018 in Applied Spectroscopy
Due to the influence of self-absorption of major elements, scarce observable spectral lines of trace elements, and relative efficiency correction of experimental system, accurate quantitative analysis with calibration-free laser-induced breakdown spectroscopy (CF-LIBS) is in fact not easy. In order to overcome these difficulties, standard reference line (SRL) combined with one-point calibration (OPC) is used to analyze six elements in three stainless-steel and five heat-resistant steel samples. The Stark broadening and Saha-Boltzmann plot of Fe are used to calculate the electron density and the plasma temperature, respectively. In the present work, we tested the original SRL method, the SRL with the OPC method, and intercept with the OPC method. The final calculation results show that the latter two methods can effectively improve the overall accuracy of quantitative analysis and the detection limits of trace elements.
29 June 2022 in Plasma Science and Technology
The optimal spectral excitation and acquisition scheme is explored by studying the effect of the lens-to-sample distance (LTSD) on the spatial homogeneity and emission spectra of flat-top laser converging spot induced plasma. The energy distribution characteristics before and after the convergence of the laser beam with quasi flat-top intensity profile used in this study are theoretically simulated and experimentally measured. For an aspheric converging mirror with a focal length of 100 mm, the LTSD (106 mm ≥ LTSD ≥ 96 mm) was changed by raising the stainless-steel sample height. The plasma images acquired by ICCD show that there is air breakdown when the sample is below the focal point, and a ring-like plasma is produced when the sample is above the focal point. When the sample is located near the focal point, the plasma shape resembles a hemisphere. Since the spectral acquisition region is confined to the plasma core and the image contains all the optical information of the plasma, it has a lower relative standard deviation (RSD) than the spectral lines. When the sample surface is slightly higher than the focal plane of the lens, the converging spot has a quasi flat-top distribution, the spatial distribution of the plasma is more uniform, and the spectral signal is more stable. Simultaneously, there is little difference between the RSD of the plasma image and the laser energy. In order to further improve the stability of the spectral signal, it is necessary to expand the spectral acquisition area.
1 February 2019 in AIP Advances
We investigated the effect of distance between the laser spot and the cavity center on spatially confined laser-induced copper plasma in air. Spatial cylindrical cavities with various diameters (2mm, 3mm, 4mm and 5mm) and heights (2mm, 4mm, 6mm and 8mm) were used to confine the plasma, and different enhancements were observed when the laser spot at different locations in the same cavity. The maximum enhancement factor for the spectral intensity of Cu atomic line to be around 9 was measured at a time delay of 2.5μs when the distance was 0mm. The plasma temperature was calculated by the Boltzmann plot method, including five Cu atomic lines (324.75nm, 327.40nm, 510.55nm, 515.32nm and 521.82nm). The enhancement of the plasma temperature had a similar trend with the spectral intensity and also showed a strong dependence on the distance. The results demonstrated that the enhancement effect at the center of the cavity was the most significant for the uniform and balanced compression of the reflected shock waves in all directions.
2 July 2025 in Applied Spectroscopy
Rocks are an extremely important and indispensable part of the Earth's crust, with wide applications in various fields such as geology, environmental monitoring, and industry. Traditional methods often rely on a single analytical technique or visual inspection, but this may not achieve the accuracy required for thorough classification. Laser-induced breakdown spectroscopy (LIBS) technology mainly provides information on the composition and content of rock elements, while images can provide appearance information such as color and texture. The multilayer perceptron (MLP) and DenseNet121 models were selected for processing preprocessed LIBS and image data, respectively. When using LIBS and images separately for classification, the accuracy rates were 93.63% and 90.90%, respectively. However, after fusing the bimodal data using LIBS and images, we achieved a significant performance improvement of 97.27% in accuracy. This study indicates that advanced neural network models can effectively integrate LIBS and image data and improve the performance of rock classification.