Teeranan Laohawiriyakamol

Teeranan Laohawiriyakamol

Auto-generated profile, based on publicly available information

Teeranan Laohawiriyakamol

Department of Radiology, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla 90110

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Journal of Clinical Orthopaedics and Trauma
Verified
Journal Article
Open access
KIKhanin Iamthanaporn
Khanin Iamthanaporn
VYVarah Yuenyongviwat
Varah Yuenyongviwat
TLTeeranan Laohawiriyakamol
Teeranan Laohawiriyakamol
PTPramot Tanutit
Pramot Tanutit
Minimally invasive surgery (MIS) in total knee arthroplasty has the benefits of less postoperative pain and a faster recovery time. An MIS instrument was designed to help surgeons perform this procedure under reduced visualization conditions. A medial cutting guide of the distal femur is used to cut the distal femoral bone without patella subluxation. This study aimed to compare the accuracy of the distal femoral bone cut between the medial and standard anterior cutting guides. Two orthopedic surgeons, who specialize in total knee arthroplasty and are familiar with both of these cutting guides, performed the procedures. Forty-eight synthetic saw bones were used, and five-degree valgus medial and anterior cutting guides were randomly assigned to the surgeons. After the osteotomies were performed, the synthetic saw bones were investigated via plain radiographs. Two independent radiologists measured the medial distal femoral angle (MDFA) and the posterior distal femoral angle (PDFA). The MDFA in the medial cutting group was statistically significantly different from that of the anterior cutting group (94.18° ± 1.47° vs. 94.98° ± 1.14°, P = 0.041). However, the PDFA was not different between the two groups. Likewise, the number of outliers was not different between the groups when a ± 2° error was defined as an outlier (P = 0.609 for MDFA and P = 0.359 for PDFA). Moreover, a high degree of reliability was found in both MDFA and PDFA measurements (intraclass correlation coefficients = 0.813 and 0.824, respectively). In this experimental study, the MIS medial cutting guide was less accurate than the standard cutting guide in the distal femoral cut.

8 January 2025 in Journal of Health Science and Medical Research
Verified
Journal Article
Open access
PDF file
WPWisitsak Pakdee
Wisitsak Pakdee
WKWarunee Kaewpiboon
Warunee Kaewpiboon
TLTeeranan Laohawiriyakamol
Teeranan Laohawiriyakamol
PBPattira Boonsri
Pattira Boonsri
KIKhanin Iamthanaporn
Khanin Iamthanaporn
PTPramot Tanutit
Pramot Tanutit
Objective: Plain radiographs are vital for initial evaluations of bone tumors. However, multiplanar imaging; like magnetic resonance imaging (MRI), is often necessary for inconclusive cases. Hence, we aimed to determine the diagnostic value of MRI in evaluating bone tumor matrix and analyzing MRI characteristics of the matrix.Material and Methods: This study reviewed 245 MRI and plain radiographs of pathologically confirmed bone tumors; including 123 mineralized and 122 non-mineralized bone tumors. A radiologist having 16 years of experience assessed tumor matrix characteristics, including border, signal intensity on T1-weighted (T1W), T2-weighted (T2W), and gradient-echo images, along with enhancement patterns. Sensitivity, specificity, and a 95% confidence interval were used to present diagnostic values.Results: MRI demonstrated a sensitivity and specificity of 78.1% and 87.7% in differentiating mineralized from non-mineralized matrices, compared to 75.6% and 92.6% for plain radiographs. Both modalities showed high sensitivity and specificity in evaluating osteoid and chondroid matrices (MRI: 80.3%/84.0%, 94.5%/96.8%; radiographs: 80.3%/72.0%, 95.1%/96.4% specificity). High specificity was noted in evaluating fibrous matrices (97.4%/99.6%) but with low sensitivity (23.5%/11.8%). MRI outperformed radiographs in subcategorizing fat, soft tissue, and cystic tumors. The chondroid matrix exhibited distinct characteristics on MRI (well-defined lobulated border with high/intermediate T2W and lobulated/peripheral enhancement), while osteoid and fibrous matrices showed similar features, except in T1W signal intensity. Non-mineralized tumors displayed varied characteristics.Conclusion: While plain radiographs are essential for initial bone tumor assessment, especially for mineralization, MRI is superior in evaluating tumor matrices and non-mineralized tissues in providing detailed characterization for staging and treatment planning.

21 February 2024 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
PTPramot Tanutit
Pramot Tanutit
PBPattira Boonsri
Pattira Boonsri
TLTeeranan Laohawiriyakamol
Teeranan Laohawiriyakamol
TBTanarat Boonriong
Tanarat Boonriong
WPWACHIRAPHAN PARINYAKHUP
WACHIRAPHAN PARINYAKHUP
Chaiwat ChuaychoosakoonChaiwat Chuaychoosakoon
Chaiwat Chuaychoosakoon
Background: Various studies have examined the risk of peroneal nerve injury with use of standard magnetic resonance imaging (MRI) of the knee. However, the position of the knee during standard MRI is different from that during an actual arthroscopic lateral meniscal repair. The purpose of the present study was to evaluate and compare the risk of peroneal nerve injury during simulated all-inside lateral meniscal repairs on the basis of MRI scans made with the knee in both positions. Methods: With use of axial MRI scans made with the knee in the standard position (i.e., in 30° of flexion) and in the actual position used during arthroscopic lateral meniscal repair (i.e., in a figure-of-4 position), direct lines were drawn to simulate the passage of a straight all-inside meniscal repair device from the anteromedial and anterolateral portals to the medial and lateral borders of the popliteus tendon. The distance from the closest passage of each line to the peroneal nerve was measured. If a line touched or passed through the peroneal nerve, a risk of iatrogenic injury was noted and a new line was drawn from the same portal to the outer border of the peroneal nerve. The danger area was measured from the first line to the new line along the joint capsule. Results: In 28 Thai patients, the shortest distances from each line to the peroneal nerve were significantly shorter on the MRI scans made with the knee in the standard position than on those made with the knee in the arthroscopic position (p < 0.05 for all). All danger areas on the MRI scans that were made with the knee in the arthroscopic position were included within the danger areas on the scans that were made with the knee in the standard position. Conclusions: Standard MRI scans of the knee can be used to determine the risk of peroneal nerve injury at the time of arthroscopic lateral meniscal repair, although the risks are slightly overestimated. Level of Evidence: Diagnostic Level III. See Instructions for Authors for a complete description of levels of evidence.

29 October 2026 in British Journal of Radiology
Verified
Journal Article
Closed access
WPWisitsak Pakdee
Wisitsak Pakdee
SSSorawat Sangkaew
Sorawat Sangkaew
PBPattira Boonsri
Pattira Boonsri
TLTeeranan Laohawiriyakamol
Teeranan Laohawiriyakamol
PCPanjai Choochuen
Panjai Choochuen
PTPramot Tanutit
Pramot Tanutit
Objectives: Establishing optimal sarcopenia cutoffs is essential, as L3 is not always included in CT imaging, and reference levels vary across populations. The absence of Southeast Asia-specific thresholds may lead to misclassification, highlighting the need for regionally appropriate diagnostic criteria. This study establishes population-specific sarcopenia cutoffs (T10-S1) in the Thai population and defines BMI-adjusted thresholds. It also assesses skeletal muscle index (SMI) correlations across vertebral levels to refine L3-based sarcopenia evaluation. Methods: This retrospective study analyzed 475 healthy Thai adults (aged 18-40 years) who underwent emergency department CT between January 2010 and June 2023. Skeletal muscle parameters were measured from T10 to S1 using custom software. Measurements included skeletal muscle area (SMA), skeletal muscle radiation attenuation (SMRA), SMI, and height-adjusted SMI (SMIH1). Sex-stratified analyses and correlations between vertebral levels were performed. Results: At L3, sarcopenia cutoffs using SMI and SMIH1 were 23.3 cm2/m2 and 37.1 cm2/m for females, and 31.3 cm2/m2 and 53.9 cm2/m for males, respectively. Strong correlations were observed between L3 and adjacent vertebral levels (r > 0.8), with correlation strength decreasing with anatomical distance. Application of international cutoffs to the Thai population resulted in overestimation of sarcopenia cases. BMI-adjusted variable thresholds demonstrated superior diagnostic accuracy compared to fixed cutoffs. Conclusions: This study establishes the first population-specific sarcopenia reference values for Thai adults and validates the use of alternative vertebral levels when L3 imaging is unavailable. Our findings emphasize the importance of population-specific and BMI-adjusted cutoff values for accurate sarcopenia diagnosis in Thai adults. Advances in knowledge: This study establishes the first population-specific sarcopenia cutoff values for healthy Thai adults, providing the first evidence-based reference standards for the Thai populations. At L3, the recommended cutoffs are SMI 23.3 cm2/m2 and SMIH1 37.1 cm2/m for females, and SMI 31.3 cm2/m2 and SMIH1 53.9 cm2/m for males. Strong correlations (r > 0.8) between L3 and adjacent vertebral levels validate the use of alternative assessment sites when L3 imaging is unavailable: T12-L1 for chest CT protocols, L3 for abdominal CT protocols, and L4-L5 for pelvic CT protocols. Application of Western cutoffs to the Thai populations results in significant overestimation of sarcopenia prevalence, emphasizing the critical importance of population-specific diagnostic criteria.