10 February 2009 in Physics in Medicine & Biology
Magnetic particle imaging (MPI) is a new tomographic imaging method potentially capable of rapid 3D dynamic imaging of magnetic tracer materials. Until now, only dynamic 2D phantom experiments with high tracer concentrations have been demonstrated. In this letter, first in vivo 3D real-time MPI scans are presented revealing details of a beating mouse heart using a clinically approved concentration of a commercially available MRI contrast agent. A temporal resolution of 21.5 ms is achieved at a 3D field of view of 20.4 x 12 x 16.8 mm(3) with a spatial resolution sufficient to resolve all heart chambers. With these abilities, MPI has taken a huge step toward medical application.
1 April 2009 in BMC Medical Imaging
Magnetic particle imaging (MPI) is a new tomographic imaging technique capable of imaging magnetic tracer material at high temporal and spatial resolution. Image reconstruction requires solving a system of linear equations, which is characterized by a "system function" that establishes the relation between spatial tracer position and frequency response. This paper for the first time reports on the structure and properties of the MPI system function.
14 March 2006 in Magnetic Resonance in Medicine
17 February 2010 in Physics in Medicine & Biology
Magnetic particle imaging (MPI) is a new imaging technique capable of imaging the distribution of superparamagnetic particles at high spatial and temporal resolution. For the reconstruction of the particle distribution, a system of linear equations has to be solved. The mathematical solution to this linear system can be obtained using a least-squares approach. In this paper, it is shown that the quality of the least-squares solution can be improved by incorporating a weighting matrix using the reciprocal of the matrix-row energy as weights. A further benefit of this weighting is that iterative algorithms, such as the conjugate gradient method, converge rapidly yielding the same image quality as obtained by singular value decomposition in only a few iterations. Thus, the weighting strategy in combination with the conjugate gradient method improves the image quality and substantially shortens the reconstruction time. The performance of weighting strategy and reconstruction algorithms is assessed with experimental data of a 2D MPI scanner.
25 November 2014 in IEEE Transactions on Medical Imaging
Magnetic particle imaging (MPI) shows promise for medical imaging, particularly in angiography of patients with chronic kidney disease. As the first biomedical imaging technique that truly depends on nanoscale materials properties, MPI requires highly optimized magnetic nanoparticle tracers to generate quality images. Until now, researchers have relied on tracers optimized for MRI T2*-weighted imaging that are sub-optimal for MPI. Here, we describe new tracers tailored to MPI's unique physics, synthesized using an organic-phase process and functionalized to ensure biocompatibility and adequate in vivo circulation time. Tailored tracers showed up to 3 × greater signal-to-noise ratio and better spatial resolution than existing commercial tracers in MPI images of phantoms.
1 June 2012 in IEEE Transactions on Medical Imaging
Magnetic particle imaging (MPI) is a new tomographic imaging approach that can quantitatively map magnetic nanoparticle distributions in vivo. It is capable of volumetric real-time imaging at particle concentrations low enough to enable clinical applications. For image reconstruction in 3-D MPI, a system function (SF) is used, which describes the relation between the acquired MPI signal and the spatial origin of the signal. The SF depends on the instrumental configuration, the applied field sequence, and the magnetic particle characteristics. Its properties reflect the quality of the spatial encoding process. This work presents a detailed analysis of a measured SF to give experimental evidence that 3-D MPI encodes information using a set of 3-D spatial patterns or basis functions that is stored in the SF. This resembles filling 3-D k-space in magnetic resonance imaging, but is faster since all information is gathered simultaneously over a broad acquisition bandwidth. A frequency domain analysis shows that the finest structures that can be encoded with the presented SF are as small as 0.6 mm. SF simulations are performed to demonstrate that larger particle cores extend the set of basis functions towards higher resolution and that the experimentally observed spatial patterns require the existence of particles with core sizes of about 30 nm in the calibration sample. A simple formula is presented that qualitatively describes the basis functions to be expected at a certain frequency.