Peter Huthwaite

Peter Huthwaite

Auto-generated profile, based on publicly available information

Peter Huthwaite

Imperial College London

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2013 in Wave Motion
Verified
Journal Article
Closed access
PHPeter Huthwaite
Peter Huthwaite
FSFrancesco Simonetti
Francesco Simonetti

1 September 2011 in The Journal of the Acoustical Society of America
Verified
Journal Article
Open access
PHP. Huthwaite
P. Huthwaite
FSF. Simonetti
F. Simonetti
Breast ultrasound tomography has the potential to improve the cost, safety, and reliability of breast cancer screening and diagnosis over the gold-standard of mammography. Vital to achieving this potential is the development of imaging algorithms to unravel the complex anatomy of the breast and its mechanical properties. The solution most commonly relied upon is time-of-flight tomography, but this exhibits low resolution due to the presence of diffraction effects. Iterative full-wave inversion methods present one solution to achieve higher resolution, but these are slow and are not guaranteed to converge to the correct solution. Presented here is HARBUT, the hybrid algorithm for robust breast ultrasound tomography, which utilizes the complementary strengths of time-of-flight and diffraction tomography resulting in a direct, fast, robust and accurate high resolution method of reconstructing the sound speed through the breast. The algorithm is shown to produce accurate reconstructions with realistic data from a complex three-dimensional simulation, with masses as small as 4 mm being clearly visible.

1 January 2019 in NDT & E International
Verified
Journal Article
Closed access
NSN.J. Shipway
N.J. Shipway
TBT.J. Barden
T.J. Barden
PHP. Huthwaite
P. Huthwaite
MLM.J.S. Lowe
M.J.S. Lowe

8 June 2014 in Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences
Verified
Journal Article
Closed access
PDF file
PHP. Huthwaite
P. Huthwaite
Accurate inversion is vital for quantitative imaging, including ultrasonic guided wave tomography, where thickness maps of plate-like structures are reconstructed to quantify corrosion damage. The dispersive properties of guided waves are often exploited to enable thickness maps to be produced from wave speed reconstructions. Ray tomography, diffraction tomography and a hybrid algorithm combining their features were investigated to reconstruct wave speed. Test data produced from simple defects of different sizes using a realistic full elastic guided wave model and the equivalent idealized acoustic model were passed to the imaging algorithms, generating wave speed maps, and, from these, thickness maps. For both datasets, ray tomography exhibited poor resolution. Diffraction tomography performed better, but was limited to shallow, small defects. The hybrid algorithm achieved the best results, giving a resolution around 1.5–2 wavelengths from the realistic test data compared to half wavelength from the idealized case. These results were validated with experimental data, and also extended to a realistic corrosion patch confirming the trends demonstrated with simple defects. The resolution loss with realistic data compared with idealized data indicates the acoustic model cannot accurately capture guided wave scattering and an alternative approach is necessary for better resolution reconstructions.

3 June 2013 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
PHPeter Huthwaite
Peter Huthwaite
RRRemo Ribichini
Remo Ribichini
PCPeter Cawley
Peter Cawley
MLMichael J.S. Lowe
Michael J.S. Lowe
Guided wave tomography offers a method to accurately quantify wall thickness losses in pipes and vessels caused by corrosion, using ultrasonic waves transmitted over distances of approximately 1 to 2 m, and measured by an array of transducers. These measurements are then used to reconstruct a map of wall thickness throughout the inspected region. To achieve accurate estimations of remnant wall thickness, it is vital that a suitable Lamb mode is chosen. This paper presents a detailed evaluation of the two most suitable modes, S0 and A0, to compare their performance using both numerical and experimental data. The sensitivity of A0 to thickness variations was shown to be superior to S0; however, the attenuation from A0 when a liquid loading was present was much higher than S0. A0 was less sensitive to the presence of coatings on the surface than was S0. Finally, it was shown that both modes could achieve a similar level of resolution in the plane of the plate surface.

1 October 2020 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
PDF file
MHM. Huang
M. Huang
GSG. Sha
G. Sha
PHP. Huthwaite
P. Huthwaite
SRS. I. Rokhlin
S. I. Rokhlin
MLM. J. S. Lowe
M. J. S. Lowe
Three-dimensional finite element (FE) modelling, with representation of materials at grain scale in realistic sample volumes, is capable of accurately describing elastic wave propagation and scattering within polycrystals. A broader and better future use of this FE method requires several important topics to be fully understood, and this work presents studies addressing this aim. The first topic concerns the determination of effective media parameters, namely, scattering induced attenuation and phase velocity, from measured coherent waves. This work evaluates two determination approaches, through-transmission and fitting, and it is found that these approaches are practically equivalent and can thus be used interchangeably. For the second topic of estimating modelling errors and uncertainties, this work performs thorough analytical and numerical studies to estimate those caused by both FE approximations and statistical considerations. It is demonstrated that the errors and uncertainties can be well suppressed by using a proper combination of modelling parameters. For the last topic of incorporating FE model information into theoretical models, this work presents elaborated investigations and shows that to improve agreement between the FE and theoretical models, the symmetry boundary conditions used in FE models need to be considered in the two-point correlation function, which is required by theoretical models.