9 August 2011 in Energy & Environmental Science
The thermodynamics and kinetics of hydrogen (H2) release from ethane 1,2-di-amineborane (EDAB, BH3NH2CH2CH2NH2BH3) were measured using Calvet and differential scanning calorimetry (DSC), pressure-composition isotherms, and volumetric gas-burette experiments. The results presented here indicate that EDAB releases ∼ 10 wt.% H2 at temperatures ranging from 100 °C to 200 °C in two moderately exothermic steps, approximately −10 ± 1 kJ mol−1 H2 and −3.8 ± 1 kJ mol−1 H2. Isothermal kinetic analysis shows that EDAB is more stable than ammonia borane (AB) at temperatures lower than 100 °C; however, the rates of hydrogen release are faster for EDAB than for AB at temperatures higher than 120 °C. In addition, no volatile impurities in the H2 released by EDAB were detected by mass spectrometry upon heating with 1 °C min−1 to 200 °C in a calorimeter.
12 October 2010 in Chemical Communications
[(NH3)2BH2]+[BH4]− is formed from the room temperature decomposition of NH4 +BH4 −, via a NH3BH3 intermediate. Its crystal structure has been determined and contains disordered BH4 − ions in 2 distinct sites. Hydrogen release is similar to that from NH3BH3 but with faster kinetics.
1 April 2019 in Physics of Plasmas
The temporal evolution of plasma density and electron temperature in high power impulse magnetron sputtering discharges has been measured using the Langmuir probe and laser Thomson scattering techniques. Measurements were performed (nonsimultaneously) at two positions within the plasma, in the low magnetic field strength region on the discharge axis and in the high magnetic field strength region of the magnetic trap, for peak power densities of 450 W cm–2 and 900 W cm−2, respectively. The maximum plasma densities and temperatures were 6.9 × 1019 m−3 and 3.7 eV in the pulse-on time, and values decayed to 4.5 × 1017 m−3 and 0.1 eV at times up to 250 μs into the afterglow. The results indicate that although intrusive, the Langmuir probe can provide a good indication of electron properties in regions of different electron magnetization in the discharge.
27 February 1995 in Applied Physics Letters
The importance of capacitively coupled radio frequency (rf) discharges has resulted in many attempts, by experiment and by simulation, to understand the dynamics of the discharge. Because of the time varying nature of the sheath potential, the sheath region is of special interest in these plasmas. Direct measurements are reported of the sheath electric fields in a helium plasma obtained using a laser induced fluorescence method. In the interpretation of these measurements, the time dependence of the fluorescence spectrum had to be considered. The measured electric field distributions can be used to deduce sheath widths.
1 July 2019 in Physics of Plasmas
Electron property measurements made by Langmuir probes and laser Thomson scattering have been compared in weakly magnetized plasma conditions using a planar unbalanced magnetron with the aim of assessing the accuracy of the probe diagnostic. The measurements were performed at several locations within the magnetic field configuration, the magnetic null region ( mT) on the discharge axis and inside the last closed flux surface boundary with fields up to 33 mT. There was good diagnostic agreement during High Power Impulse Magnetron Sputtering, but significant discrepancies were observed for DC magnetron operation, even at the magnetic null. For some discharge conditions, the electron density determined by Thomson scattering was over an order of magnitude greater than the plasma density obtained from the Langmuir probe, using both ion and electron collection theories. In addition, the low energy part of the electron energy distribution function determined by the probe was depleted. The possible reasons for the discrepancies are discussed, with the conclusion being that the plasma was significantly perturbed by the probe stem. The range of plasma densities and electron temperatures measured in this study were 0.4–54 × 1017 m−3 and 0.2–5.9 eV, respectively.
1 April 2021 in Review of Scientific Instruments
A new divertor Thomson scattering system has been developed for the MAST-U tokamak. The diagnostic will produce electron density and temperature profiles along the Super-X strike leg. The existing polychromator design has been adapted for low temperature measurements. A new 1061 nm channel with 2 nm bandwidth has been added to enable measurements down below the previous ∼5 eV limit on the core system. The optical filters used in the system have OD6 light rejection alongside a 1064.1 nm laser line filter to reduce stray light in the digitized channels. A new averaging technique has been applied to the scattered signal traces to improve the core Thomson data in the scrape-off layer. The technique reduces the systematic noise level in this region. This leads to a reduction in the error values for electron density and temperature measurements and, in particular, the digitizer noise. The technique has been applied to produce a radial profile for a number of L-mode MAST discharges down to very low densities of ∼1 × 1018 m−3.