Shuai Yuan

Shuai Yuan

Auto-generated profile, based on publicly available information

Shuai Yuan

High voltage Institute China Electric Power Research Institute,Beijing,China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 March 2018 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
Jinwei HeJinwei He
Jinwei He
LDLiyang Du
Liyang Du
SYShuai Yuan
Shuai Yuan
CZChenghui Zhang
Chenghui Zhang
CWChengshan Wang
Chengshan Wang
A modified multi-port converter topology is proposed for active power quality control of two-ac-bus grid while maintaining a flexible integration of distributed DC energy sources. In this system, the lower converter cells work in voltage controlled mode (VCM) to supply power to autonomous local critical loads with reduced harmonic distortions. At the same time, the upper converter cells working in current controlled mode (CCM) are placed in between the main grid and the lower cells, to block the harmonic current from the local nonlinear loads to pollute the higher voltage grid current. In this proposed system, the upper and lower power cells harmonic control are well decoupled with minimal interferences. This features reduced computational load as there is no need to use any harmonic components extractions in the whole compensation process. In addition, the proposed harmonic compensation method has no interference with the interphase power flow control through zero sequence voltage injection. It has been examined that the proposed power quality control method works well in various conditions including that with large grid impedance and DC rail voltage variations.

15 October 2021
Verified
Conference Paper
Closed access
FDFei Du
Fei Du
GWGuangzhen Wang
Guangzhen Wang
SYShuai Yuan
Shuai Yuan
ZLZhiyuan Liu.
Zhiyuan Liu.
LSLei Shi
Lei Shi
XZXinyang Zhao
Xinyang Zhao
To monitor the surface discharge with high sensitivity in the converter valve, the ultraviolet array sensor is designed. The propagation mode of ultraviolet signal of surface discharge of converter valve is analyzed by ray tracing method, and the direction algorithm of surface discharge based on phased array technology is proposed, and the noise space and signal subspace of 4-channel ultraviolet signal are extracted by rotating signal subspace algorithm. The positioning results of multiple surface discharges are simulated and analyzed, and the direction error is less than 1 degree, which provides a new algorithm for non-intrusive condition monitoring of converter valve.