Burcu Bal

Burcu Bal

Auto-generated profile, based on publicly available information

Burcu Bal

YEDITEPE UNIVERSITY, FACULTY OF DENTISTRY

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2014 in Cranio®
Verified
Journal Article
Closed access
NTNeslihan Tinastepe
Neslihan Tinastepe
BKBurcu Bal Kucuk
Burcu Bal Kucuk
KOKoray Oral
Koray Oral
Objective: Phantom bite is a rare and challenging condition that dentists may encounter in their daily clinical practice. Patients with phantom bite typically present with many failed repeated occlusal treatments, such as full-mouth prosthetic reconstructions and orthodontic treatments, to overcome their distressing symptoms. Method and result: A 55-year-old female with no history of medical problems presented with bite discomfort. She complained of discomfort from a "bite'' and pressure-like feeling in her right upper three maxillary posterior teeth. Examination revealed no temporomandibular disorder (TMD) abnormalities. A thorough evaluation of her oral structures revealed no dental, periodontal, or mucosal pathologies. Conclusion: Owing to the great potential of conditions for financial loss and litigation problems, dentists, particularly those who perform bite-changing procedures, should be aware of this condition. This case is presented to highlight many of the clinical characteristics of phantom bite.

10 December 2021 in Cranio®
Verified
Journal Article
Closed access
SASerdar Ahci
Serdar Ahci
BBBurcu Bal
Burcu Bal
GBGulcin Benbir-Senel
Gulcin Benbir-Senel
DKDerya Karadeniz
Derya Karadeniz
KOKoray Oral
Koray Oral
This study aimed to evaluate the clinical and polysomnographic characteristics of sleep bruxism (SB) and delineate the determinant factors for temporomandibular disorders (TMD). Forty-six patients were allocated into the SB group (n = 26) and control group (n = 20). The signs and symptoms of TMD were recorded using the Research Diagnostic Criteria for TMD. Patients underwent a full-night polysomnographic recording and masseter and temporal muscle electromyographic recordings. Clinical and polysomnographic data in patients with SB were analyzed in relation to TMD. The presence of TMJ sounds was significantly correlated with the number of bruxism bursts. Intra-articular pain in the TMJ was neither correlated with clinical nor polysomnographic parameters in patients with SB. Lower sleep efficiency in patients with SB was caused by a higher number of bruxism episodes. Morning headaches were associated with the severity of SB during rapid eye movement sleep.

23 June 2020 in Dental Traumatology
Verified
Journal Article
Closed access
PDF file
BBBurcu Bal
Burcu Bal
TKTemel Koksal
Temel Koksal
BEBugce Ebeoglu
Bugce Ebeoglu
KOKoray Oral
Koray Oral

3 September 2015 in Folia Morphologica
Verified
Journal Article
Closed access
PDF file
BBBurcu Bal
Burcu Bal
IDIdil Dikbas
Idil Dikbas
OMOzlem Malkondu
Ozlem Malkondu
KOKoray Oral
Koray Oral
Background: The aim of this study was to estimate the prevalence of ramus asymmetries related to age and gender in a young population and the influence of growth spurt on ramus asymmetry. Materials and methods: The study consisted of 776 panoramic radiographs of individuals aged 9 to 21 years (335 males and 441 females). Individuals were divided into two groups with respect of linear growth spurt as age 12 in females and age 14 in males. The first group consisted of females aged between 9-11 and males between 9-13. The second group consisted of females aged between 12-21 and males between 14-21. Bilateral ramus heights on each radiograph were measured. A panoramic software program was used to measure the ramus heights. Quantitative data was tested by Student’s t test. Qualitative data was tested by chi-square test. The intraclass correlation coefficient (ICC) was calculated for the magnitude error of the measurement. Results: The mean of ramus asymmetry was found to be 2.90±2.58%. Significant differences between the right and left ramus height ratios were observed (p<0.01). There was a high prevalence (10.8%) of ramus asymmetry, which did not correlate with the age, and gender of the patients. Conclusions: This study revealed a high prevalence of ramus asymmetry in 9-21 year old population. Within the limitations of this study, it can be concluded that ramus asymmetry should carefully be evaluated in all ages for the potential relation with temporomandibular dysfunctions and also for orthodontic anomalies. Background: The aim of this study was to estimate the prevalence of ramus asymmetries related to age and gender in a young population and the influence of growth spurt on ramus asymmetry. Materials and methods: The study consisted of 776 panoramic radiographs of individuals aged 9 to 21 years (335 males and 441 females). Individuals were divided into two groups with respect of linear growth spurt as age 12 in females and age 14 in males. The first group consisted of females aged between 9-11 and males between 9-13. The second group consisted of females aged between 12-21 and males between 14-21. Bilateral ramus heights on each radiograph were measured. A panoramic software program was used to measure the ramus heights. Quantitative data was tested by Student’s t test. Qualitative data was tested by chi-square test. The intraclass correlation coefficient (ICC) was calculated for the magnitude error of the measurement. Results: The mean of ramus asymmetry was found to be 2.90±2.58%. Significant differences between the right and left ramus height ratios were observed (p<0.01). There was a high prevalence (10.8%) of ramus asymmetry, which did not correlate with the age, and gender of the patients. Conclusions: This study revealed a high prevalence of ramus asymmetry in 9-21 year old population. Within the limitations of this study, it can be concluded that ramus asymmetry should carefully be evaluated in all ages for the potential relation with temporomandibular dysfunctions and also for orthodontic anomalies.

1 October 2022 in Cumhuriyet Dental Journal
Verified
Journal Article
Open access
PDF file
YÖYunus Emre Özden
Yunus Emre Özden
AYAyse Yalniz
Ayse Yalniz
BBBurcu Bal
Burcu Bal
ZEYNEP OZKURT-KAYAHANZEYNEP OZKURT-KAYAHAN
ZEYNEP OZKURT-KAYAHAN
Ender KazazogluEnder Kazazoglu
Ender Kazazoglu
Objectives: Although spectrophotometers are commonly used in shade analysis in dentistry; digital cameras, photographic lighting systems, computer programs and photographs have also become the part of this field. The aim of this study was to compare the success of spectrophotometer and calibrated digital photography on shade selection. Materials and Methods: 3D-Master toothguide (VITA) with 29 tabs was used for the analyses. L, a, b values were determined by a spectrophotometer (Minolta CM-2300D, Konica) and these values were matched with digital photographic measurements. Photographs were transferred to an image analyzing software (Adobe Photoshop CC). Results: There were significant differences between L* values of the spectrophotometric analyses and digital measurements in 3 different regions of the tab (p<0.05). For the evaluation of ΔE values, Post hoc Bonferroni analysis which was performed between the 3 regions of shade tabs revealed significant difference between the middle (21.92 ± 2.31), incisal (13.67 ± 1.69) and cervical (19.57 ± 2.47) region of the tabs (p<0.05). Conclusion: Spectrophotometer was found to be a more accurate shade determination technique compared to calibrated digital photography.

1 June 2024 in The International Journal of Prosthodontics
Verified
Journal Article
Closed access
BBBurcu Bal
Burcu Bal
SESelen Erkul
Selen Erkul
ZOZeynep Ozkurt-Kayahan
Zeynep Ozkurt-Kayahan
EKEnder Kazazoglu
Ender Kazazoglu
Purpose: To measure and compare the mean temperature values due to heat generated during the grinding of different prosthetic materials with diamond burs using a high-speed instrument with and without water cooling. Materials and Methods: In total, 120 disk-shaped specimens (10 × 2 mm), each with ...