Tanja Šašić-Ostojić

Tanja Šašić-Ostojić

Auto-generated profile, based on publicly available information

Tanja Šašić-Ostojić

Center of Laboratory Diagnostics University Clinical Centre of Vojvodina 1-9 Hajduk Veljkova Street Novi Sad Serbia

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 November 2022 in Medicina
Verified
Journal Article
Open access
PDF file
MPMarija Vukmirović Papuga
Marija Vukmirović Papuga
ZBZoran Bukumirić
Zoran Bukumirić
BIBranislava Ilinčić
Branislava Ilinčić
RMRomana Mijović
Romana Mijović
TOTanja Šašić Ostojić
Tanja Šašić Ostojić
RŽRadmila Žeravica
Radmila Žeravica
Background and Objectives: In chronic kidney obstruction, the severity of tubulointerstitial damage correlates best with the loss of kidney function and the risk for progression to end-stage kidney disease. The present study aimed to investigate the potential clinical significance of serum uromodulin (sUmod) as a marker of early kidney disfunction in patient with obstructive nephropathy (ON). Materials and Methods: Serum Umod level was measured by sensitive ELISA method in 57 adult patients with obstructive nephropathy and 25 healthy subjects in control group. Kidney function was precisely evaluated via measured glomerular filtration rate (mGFR) (renal clearance of 99 mTc-diethylenetriamine penta-acetic acid), effective renal plasma flow (ERPF) and Cystatin C level. Recruited patients were divided into subgroups based on the mGFR: group I—GFR ≤ 60 mL/min/1.73 m2 (N = 31), group II—GFR > 60 mL/min/1.73 m2 (N = 26). Results: A significantly lower level of serum uromodulin was measured in patients with ON (50.2 ± 26.3 ng/mL) compared to the control group (78.3 ± 24.5 ng/mL) (p < 0.001). The mean level of serum Umod was significantly different between group I (30.5 ng/mL ± 11.1) and group II (73.6 ng/mL ± 18.6) (p < 0.001), but not between group II (73.6 ng/mL ± 18.6) and control group (78.3 ± 24.5 ng/mL). There was a positive correlation between sUmod and mGFR (R = 0.757, p < 0.001) and ERPF (R = 0.572 p < 0.001), with lower sUmod levels in patients with impaired renal function. An inverse relationship was detected between sUmod and filtration markers—cystatin C (R = −0.625, p < 0.001), creatinine, urea and uric acid. ROC analysis of sUmod to differentiate between ON patients with GFR below 60 mL/min/1.73 m2 and above 60 mL/min/1.73 m2 resulted in AUC of 0.98 (p < 0.001, 95% CI 0.922 vs. 0.998) at a cut-off value of 46 ng/mL (specificity 96.8%, sensitivity 92.2%). Conclusions: The significant correlation of sUmod with kidney function parameters may imply potential clinical significance as a noninvasive biomarker of early kidney disfunction in obstructive nephropathy.

1 January 2026 in Journal of Medical Biochemistry
Verified
Journal Article
Open access
PDF file
SNStanislava Nikolic
Stanislava Nikolic
MSMasa Sladojević
Masa Sladojević
TŠTanja Šašić-Ostojić
Tanja Šašić-Ostojić
BSBorivoj Sekulić
Borivoj Sekulić
IPIvanka Perčić
Ivanka Perčić
IBIva Barjaktarović
Iva Barjaktarović
Background: Chronic lymphocytic leukemia (CLL) represents the most frequent type of leukemia in the adult population. It is characterized by highly variable clinical course, predominantly initiated by different genetic alterations responsible for the regulation of cell proliferation and apoptosis. The aim of this study was to evaluate the relative expression of the BIRC3 gene in CLL patients. Methods: This cross-sectional study included 78 participants: a CLL group (n=50) and a control group of healthy subjects (n=28), both ageand sex-matched. To all participants, CBC (complete blood count), basic biochemical parameters, as well as FISH (fluorescent in situ hybridisation) for determining chromosomal aberrations and PCR analyses for determining the relative expression of the BIRC3 (Baculoviral IAP Repeat Containing 3) gene were performed. All reactions were performed on QIA quant 96 5 plex real-time PCR instrument (Qiagen, Hilden, Germany). Additionally, FISH diagnostics was performed using Abbott Vysis CLL FISH Probe Kit (Abbott Molecular diagnostics, Chicago, IL, USA). Results: Deletion of the long arm of the 13th chromosome was the most frequent chromosomal aberration in the CLL group. A statistically significant difference was observed in the relative expression of BIRC3, with higher values in the study group (p=0.019). The results of the binary logistic regression model indicated that lactate dehydrogenase and total calcium were statistically significant predictors of relative BIRC3 gene expression (p < 0.05). Conclusion: Determination of relative BIRC3 gene expression may be a valuable analysis for both the initial diagnosis and the clinical follow-up of CLL patients.

1 January 2020 in Medicinski Pregled
Verified
Journal Article
Closed access
JSJelena Samac
Jelena Samac
RŽRadmila Žeravica
Radmila Žeravica
BIBranislava Ilincic
Branislava Ilincic
MVMarija Vukmirovic-Papuga
Marija Vukmirovic-Papuga
DBDragan Buric
Dragan Buric
TOTanja Ostojic
Tanja Ostojic
Introduction. Radionuclide methods are used in the evaluation of different aspects of renal function. The aim of this study was to define and implement an index derived from scintigraphic image and to compare it with ortho-iodohippurate clearance values, an indicator of effective renal plasma flow. Material and Methods. A retrospective analysis included 67 adult patients, who underwent static renal scintigraphy and ortho-iodohippurate clearance. We computed the background-to-renal index that represents the ratio of average values of counts per pixel in the background regions and in the regions of kidneys. Patients were divided into three groups according to the values of measured effective renal plasma flow: group 1 - patients with mild renal dysfunction (reduction of effective renal plasma flow ? 20%, 17 patients), group 2 - moderate dysfunction (reduction of effective renal plasma flow 20-50%, 25), and group 3 - severe dysfunction (reduction of effective renal plasma flow 50-70%, 25 patients). Results. Subjects with mild effective renal plasma flow reduction had significantly lower background-to-renal index values compared to those with moderate and severe reduction [(0.105 ? 0.05) vs. (0.134 ? 0.056) vs. (0.275 ? 0.154), p < 0,001]. A significant linear correlation was found between background-to-renal index and effective renal plasma flow (r = 0.60, p < 0.0001). Sensitivity and specificity of the calculated cut-off value of 0.1335, for the differentiation between the patients with renal reduction higher and lower than 20%, were 62% and 100%, respectively (area under curve 0.85). Conclusion. The background-to-renal index is a simple method for semiquantitative estimation of global tubular renal function that can be a useful tool when determining patients for further in vitro assessment of global renal function.

1 January 2020 in Medicinski Pregled
Verified
Journal Article
Closed access
PDF file
SNStanislava Nikolic
Stanislava Nikolic
RMRomana Mijovic
Romana Mijovic
DODragana Oluski
Dragana Oluski
TOTanja Ostojic
Tanja Ostojic
IBIvana Bajkin
Ivana Bajkin
Introduction. Macroprolactinemia is one of the common causes of hyperprolactinemia, especially in cases where standard routine commercial immunometric assays are used for prolactin level measurement. Two forms of prolactin, inactive dimeric prolactin (50 - 60 kDa) and a low-activity tetramer (molecular weight above 150 kDa), contribute to this condition. The relatively low incidence of symptoms in macroprolactinemia patients has necessitated a relatively simple method to detect large, biologically inactive prolactin molecules, such as polyethylene glycol precipitation method. The aim of this study was to compare the precipitation method using polyethylene glycol dissolved in phosphate buffered saline in relation to polyethylene glycol dissolved in water. Material and Methods. This study included 82 patients who visited the Center of Laboratory Medicine, Clinical center of Vojvodina, to determine serum prolactin levels. The obtained serum samples were divided into two aliquots. The first aliquot was frozen and stored at - 20?C and the other was immediately analyzed. Aqueous solution was added to one aliquot and polyethylene glycol Merck 6000 to the other. All serum and supernatant samples were analyzed using the automated Abbott Architect i2000sr immunoassay. Recovery values were calculated as the ratio of double values of free prolactin and total prolactin concentration, expressed as a percentage. Results. The prolactin concentrations and calculated recovery values were lowest in fresh supernatant prolactin treated with phosphate buffered saline. Statistical analysis showed no significant difference in the calculated recovery values obtained by precipitation of fresh and frozen sera using polyethylene glycol dissolved in phosphate buffered saline (p = 0.893). Conclusion. Precipitation using polyethylene glycol dissolved in phosphate buffered saline is a more reliable method for laboratory detection of macroprolactinemia compared to polyethylene glycol dissolved in water.

1 January 2025 in Journal of Medical Biochemistry
Verified
Journal Article
Open access
PDF file
TŠTanja Šašić-Ostojić
Tanja Šašić-Ostojić
SNStanislava Nikolic
Stanislava Nikolic
MSMaša Sladojević
Maša Sladojević
VČVelibor Čabarkapa
Velibor Čabarkapa
DSDušan Sedlarević
Dušan Sedlarević
DŽDragana Žuvić
Dragana Žuvić
Background: The platelet-to-lymphocyte ratio (PLR) is a simple laboratory index that can be applied in the diagnosis and follow-up of various diseases, particularly those with a primary or accompanying systemic inflammatory component. However, its clinical utility is limited by the absence of established reference intervals in the general population. This study aimed to determine the reference interval for PLR. Methods: This retrospective observational study included 4,672 adults who underwent regular systematic check-ups consisting of clinical examinations and basic laboratory analyses, including a complete blood count (CBC). The PLR reference interval was calculated using Clinical and Laboratory Standards Institute (CLSI) guidelines, which estimate percentiles and their 95% confidence intervals (CI). Verification of the reference interval was performed in a group of 95 healthy adults, matched by age and sex to the study cohort. Results: The mean age of participants was 43± 10 years, with a predominance of males (83.7% ). The median PLR was 109 (25th percentile: 90; 75th percentile: 131). The lower limit of the reference interval was 62 (95% CI: 61-63), and the upper limit was 194 (95% CI: 188-198). Female participants had significantly higher PLR values compared with males (P < 0.0001), while elderly participants had significantly lower PLR values compared with the middle-aged and younger groups (P= 0.019). The determined reference interval was 70-231 for females and 61-183 for males. PLR values did not differ significantly between the primary study group and the validation group [108.0 (87-136) vs. 109.0 (90-131); P> 0.05]. Conclusions: In this representative sample, consisting primarily of young and middle-aged adults, the PLR reference interval was 70-231 for women and 61-183 for men. In individuals older than 65 years, PLR values may be lower.

1 January 2025 in Nuclear Technology and Radiation Protection
Verified
Journal Article
Open access
PDF file
RŽRadmila R. Žeravica
Radmila R. Žeravica
JSJelena J. Samac
Jelena J. Samac
MVMarija V. Vukmirović-Papuga
Marija V. Vukmirović-Papuga
AJAna J. Jakovljević
Ana J. Jakovljević
DBDragan V. Burić
Dragan V. Burić
TŠTanja M. Šašić-Ostojić
Tanja M. Šašić-Ostojić
The objective of this study was to assess the level of knowledge and awareness among referring physicians regarding diagnostic procedures involving ionizing radiation. A total of 350 physicians with varying levels of education and experience participated in a structured questionnaire. They were employed across all levels of healthcare in Vojvodina. Group 1 (G1) included physicians who had received additional training in radiation protection, while group 2 (G2) had not received this training. In G2, 44 % of respondents rated their knowledge of ionizing radiation as insufficient for routine clinical practice, and only 16.5 % were familiar with the ALARA principle. Just 20 % correctly identified diagnostic procedures that do not involve ionising radiation, whereas nearly 40 % incorrectly classified fluoroscopy, mammography and PET scans as non-ionizing. One third of participants stated that radiation exposure does not increase lifetime cancer risk. The 89 % of respondents expressed a strong demand for clear guidelines to help select diagnostic modalities based on clinical indication and patient age. Regarding unnecessary imaging referrals, 55 % cited excessive reliance on imaging, while 44 % attributed it to patient requests. This pilot study highlights the pressing need to improve education on radiation protection, especially given the increasing accessibility of advanced and hybrid imaging technologies.