29 May 2026 in Електротехнічні та інформаційні системи
Distributed generation systems (DGS) based on renewable energy sources represent an indispensable pathway for the forced transformation of Ukraine’s energy sector in the context of enhancing the reliability and energy efficiency of power supply to consumers. The simplicity and rapid deployment of photovoltaic power plants (PVPPs) have created favorable conditions for their widespread integration into distribution networks under various business models. Solar generation capacity exceeds that of all other distributed generation sources combined by a factor of four.Despite more than a decade of PVPP deployment, the methodological approaches to their design require revision and refinement to ensure more efficient utilization of network capacity, particularly that of power transformers at step-up substations and power collection substations.The aim of this paper is to substantiate a methodological approach to improving the design of power supply systems and to determine the optimal capacity of transformers for grid-connected PVPPs using desktop application for photovoltaic system simulation PVsyst.The research methodology is based on modeling and operational analysis of a typical 1 MW grid-connected PVPP using the PVsyst software package, as well as existing regulatory and technical documentation on transformer loading capacity, in order to assess their efficiency under the influence of key operational factors.The scientific novelty of the study lies in the development of a new methodological approach to selecting the optimal capacity of power transformers for PVPPs under specified operating conditions.The practical significance of the research is reflected in the possibility of applying the proposed approach by design organizations to reduce capital expenditures in PVPP construction through the selection of rational parameters of distribution equipment.
30 September 2026 in Electrical Engineering and Power Engineering
Purpose. Development of an architectural approach to the safe operation of local power systems in the autonomous Islanding mode, taking into account the risks caused by military threats, as well as determining the relationship between the structure of the power system, the redundancy of its components, power supply modes and the ability to maintain continuous power supply of critical loads in the event of a disruption of centralized power supply. Methodology. The work uses methods of system analysis and modeling of electric power regimes to study the functioning of the local power system in the Islanding mode, risk assessment methods to determine the impact of military threats, structural-functional and scenario analysis to form the architecture of backup and restoration of power supply, as well as multi-criteria evaluation to substantiate technical solutions to improve the security and stability of the power system. Findings. The architecture of the local power system for safe operation in the autonomous Islanding mode under conditions of military threats has been formed. The structure of generating and backup sources, storage devices, control, monitoring and protection systems has been determined. It is proposed to take into account the risks of infrastructure damage, loss of external power supply and component failures. Automated mode switching, priority power supply of critical consumers and phased load restoration have been justified. Originality. An architectural model for the safe operation of a local power system in Islanding mode with the integration of military threat risk assessment is proposed. The principles of component redundancy are improved, taking into account the probability of their damage and the criticality of loads. Practical value. The proposed approach can be used in the design and modernization of local power systems of critical infrastructure. The identified principles allow to justify the composition of reserve sources, reserve levels and automatic control algorithms to increase the reliability of power supply and quickly transition to a safe autonomous mode.