Natural attenuation of groundwater contamination occurs at some level for all aquifers impacted with organic contaminants. The issues regarding natural attenuation are whether it takes place at a sufficient rate to be protective of human health and the environment. Implementation of a Monitored Natural Attenuation (MNA) remedial alternative for groundwater requires parties responsible for the contamination to demonstrate to regulators and the public that MNA is protective at a given site. Analysis of MNA for remediation of karst aquifers is hampered by a lack of understanding of biodegradation in karst environments. The lack of studies examining biodegradation in karst aquifers may in large part be due to the widespread perception that contaminants are rapidly flushed out of karst aquifers resulting in insufficient residence times for contaminants to biodegrade. In highly developed and well-connected conduit systems, the rate of contaminant migration is perceived to be much faster than the rate of biodegradation. This perception of contaminant transport is largely incorrect. Tracer studies for karst aquifers often indicate that these aquifers are characterized by diverse flow regimes and storage capabilities. Additionally, it is also believed that if bioremediation in bedrock aquifers is dependent upon contact between surface-attached bacteria and contaminants, then bioremediation would be limited by the low surface-area-to-volume ratio (SA/V) of karst aquifers. A quantitative basis, however, for accepting or rejecting the assumption that attached bacteria dominate the biodegradation process in karst conduits has not been shown. The objective of this research was to determine if free-living karst bacteria from contributed as much to toluene biodegradation as attached bacteria. This is an important area of research. Research indicates bacteria are both attached and free-living in karst aquifers and it is unrealistic to think that only the attached bacteria facilitate biodegradation. The groundwater use in all tests was taken from a karst aquifer know to be impacted by BTEX. The resulting first-order rate constants were computed to be 0.014 per hour for the open system and 0.0155 per hour for the packed reactor system. Biodegradation of toluene in flow-through laboratory karst systems of varying SA/V indicated that the observed biodegradation of toluene was attributable to free-living karst bacteria and not limited by low SA/V in karst. This was evidenced by the fact that the systems with five-fold variation in SA/V were shown to have observed pseudo first order reaction rate constants that differed by only 7.0%. If attached bacteria were primarily responsible for biodegradation and limiting, a proportional difference in the observed rates relative to the difference in surface area would be expected.
The purpose of this study was to investigate the movement of chloride through a vadose zone located under failed and non-regulated septic tanks of Duhok city, Kurdistan of Iraq, potentially contaminating its groundwater. A physical vadose model (PVM) of a vertical flow direction was built in the laboratory to represent the city soil profile. The size of the PVM was 210 × 122 × 9.7 cm (height, width, and depth). Preliminary soil tests were conducted to better represent the lithology of study area. The PVM was then packed with regional silt clay soil, after modifying its texture, using an innovative packing procedure to preserve natural soil density and porosity. The model was run for a period of three months with newly collected septic water (black water from a septic tank) as an exclusive source of contaminants. Water samples from eight vertically arranged portals representing 12.5, 37.5, 62.5, 87.5, 112.5, 137.5, 162.5, and 187.5 cm levels in the subsurface soil profile were collected on a daily basis and analyzed weekly. Logistic regression and logarithmic models were developed to spatially predict the movement of chloride ions at different sampling depths in the soil profile until the system had reached the equivalent chloride concentration of the septic water or had stabilized. There was a good agreement between the physical model and the statistical models, however each model had its strengths and weaknesses. This study demonstrated that there is a potential for septic water to reach the water table within a 2–3 weeks period. Dilution and dispersion appear to play important roles in the fate and transport of septic water. This study has the potential to help the local authorities predict percolation rates and establish strategies for groundwater management in order to protect the public health.