Hwabok Wee

Hwabok Wee

Auto-generated profile, based on publicly available information

Hwabok Wee

Department of Orthopaedics and Therapy Services, Penn State College of Medicine, Hershey, PA 17033, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2021 in Current Osteoporosis Reports
Verified
Journal Article
Closed access
PDF file
GLGregory S. Lewis
Gregory S. Lewis
DMDominic Mischler
Dominic Mischler
HWHwabok Wee
Hwabok Wee
JRJ. Spence Reid
J. Spence Reid
PVPeter Varga
Peter Varga

28 December 2021 in Biomaterials
Verified
Journal Article
Closed access
KMKazim K. Moncal
Kazim K. Moncal
RAR. Seda Tigli Aydın
R. Seda Tigli Aydın
KGKevin P. Godzik
Kevin P. Godzik
TATimothy M. Acri
Timothy M. Acri
DHDong N. Heo
Dong N. Heo
Ibrahim Tarik OzbolatIbrahim Tarik Ozbolat
Ibrahim Tarik Ozbolat

27 March 2020 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
MTMaryam Tilton
Maryam Tilton
AAApril D. Armstrong
April D. Armstrong
HWHwabok Wee
Hwabok Wee
MHMichael Hast
Michael Hast
GMGuha Manogharan
Guha Manogharan
GLGregory S. Lewis
Gregory S. Lewis
Internal fixation with the use of locking plates is the standard surgical treatment for proximal humerus fractures, one of the most common fractures in the elderly. Screw cut-out through weak cancellous bone of the humeral head, which ultimately results in collapse of the fixed fracture, is the leading cause of failure and revision surgery. In an attempt to address this problem, surgeons often attach the plate with as many locking screws as possible into the proximal fragment. It is not thoroughly understood which screws and screw combinations play the most critical roles in fixation stability. This study conducted a detailed finite element analysis to evaluate critical parameters associated with screw cut-out failure. Several clinically relevant screw configurations and fracture gap sizes were modeled. Findings demonstrate that in perfectly reduced fracture cases, variation of the screw configurations had minor influence on mechanical stability of the fixation. The effects of screw configurations became substantial with the existence of a fracture gap. Interestingly, the use of a single anterior calcar screw was as effective as utilizing two screws to support the calcar. On the other hand, the variation in calcar screw configuration had minor influence on the fixation stability when all the proximal screws (A-D level) were filled. This study evaluates different screw configurations to further understand the influence of combined screw configurations and the individual screws on the fixation stability. Findings from this study may help decrease the risk for screw cut-out with proximal humerus varus collapse and the associated economic costs.

4 August 2021 in Journal of the American Academy of Orthopaedic Surgeons
Verified
Journal Article
Closed access
GLGregory S. Lewis
Gregory S. Lewis
HWHwabok Wee
Hwabok Wee
JVJared Vicory
Jared Vicory
AAApril D. Armstrong
April D. Armstrong
JRJ. Spence Reid
J. Spence Reid
Introduction: In the surgical fixation of fractures, proper biomechanical stability is key in preventing clinical complications including poor fracture healing, residual deformity, loss of fixation, or implant failure. Stability is largely influenced by treatment decisions made by the surgeon. The interplay of surgeon-controlled variables and their effect on the three-dimensional (3D) biomechanics of a fracture fixation construct are often not intuitive, and current training methods do not facilitate a deep understanding of these interactions. Methods: A simulation software interface, FracSim, was developed. FracSim is built on a large precomputed library of finite element simulations. The software allows a surgeon to make adjustments to a virtual fracture fixation construct/weight-bearing plan and immediately visualize how these changes affect 3D biomechanics, including implant stress and fracture gap strain, important for clinical success. Twenty-one orthopaedic residents completed an instructor-led educational session with FracSim focused on bridge plating. Subjects completed pretests and posttests of knowledge of biomechanical concepts and a questionnaire. Results: Subjects scored a mean of 5.6/10 on the pretest of biomechanical knowledge. Senior residents scored better than junior residents (P = 0.04). After the educational session with FracSim, residents improved their test scores to a mean of 8.0/10, with a significant improvement (P < 0.001). Questionnaire scores indicated that subjects believed that FracSim had realistic implants, constructs, and motions and that training with FracSim was purposeful, desirable, efficient, fun, and useful for enhancing the understanding of fracture fixation biomechanics. Discussion: This new type of simulation software enables interactive visualization of 3D fracture fixation biomechanics. Limitations of this study include lack of a control group undergoing traditional education and lack of a delayed posttest to assess retention. FracSim may provide an effective and engaging way to promote a deeper understanding of biomechanical concepts in the orthopaedic learner.

20 August 2022 in Injury
Verified
Journal Article
Closed access
JTJacqueline Tucker
Jacqueline Tucker
AMAndrew McCullen
Andrew McCullen
PKPatrick Kennedy
Patrick Kennedy
ZKZachary Koroneos
Zachary Koroneos
HWHwa Bok Wee
Hwa Bok Wee
MGMatthew R. Garner
Matthew R. Garner

17 June 2020 in bioRxiv
Verified
Preprint
Open access
PDF file
DHDong Nyoung Heo
Dong Nyoung Heo
Bugra AyanBugra Ayan
Bugra Ayan
MDMadhuri Dey
Madhuri Dey
DBDishary Banerjee
Dishary Banerjee
HWHwabok Wee
Hwabok Wee
Ibrahim Tarik OzbolatIbrahim Tarik Ozbolat
Ibrahim Tarik Ozbolat
Conventional top-down approaches in tissue engineering involving cell seeding on scaffolds have been widely used in bone engineering applications. However, scaffold-based bone tissue constructs have had limited clinical translation due to constrains in supporting scaffolds, minimal flexibility in tuning scaffold degradation, and low achievable cell seeding density as compared with native bone tissue. Here, we demonstrate a pragmatic and scalable bottom-up method, inspired from embryonic developmental biology, to build three-dimensional (3D) scaffold-free constructs using spheroids as building blocks. Human umbilical vein endothelial cells (HUVECs) were introduced to human mesenchymal stem cells (hMSCs) (hMSC/HUVEC) and spheroids were fabricated by an aggregate culture system. Bone tissue was generated by induction of osteogenic differentiation in hMSC/HUVEC spheroids for 10 days, with enhanced osteogenic differentiation and cell viability in the core of the spheroids compared to hMSC-only spheroids. Aspiration-assisted bioprinting (AAB) is a new bioprinting technique which allows precise positioning of spheroids (11% with respect to the spheroid diameter) by employing aspiration to lift individual spheroids and bioprint them onto a hydrogel. AAB facilitated bioprinting of scaffold-free bone tissue constructs using the pre-differentiated hMSC/HUVEC spheroids. These constructs demonstrated negligible changes in their shape for two days after bioprinting owing to the reduced proliferative potential of differentiated stem cells. Bioprinted bone tissues showed interconnectivity with actin-filament formation and high expression of osteogenic and endothelial-specific gene factors. This study thus presents a viable approach for 3D bioprinting of complex-shaped geometries using spheroids as building blocks, which can be used for various applications including but not limited to, tissue engineering, organ-on-a-chip and microfluidic devices, drug screening and, disease modeling.