1 March 2023 in Frontiers in Bioengineering and Biotechnology
Introduction: Osteoporosis is currently diagnosed based on areal bone mineral density (aBMD) computed from 2D DXA scans. However, aBMD is a limited surrogate for femoral strength since it does not account for 3D bone geometry and density distribution. QCT scans combined with finite element (FE) analysis can deliver improved femoral strength predictions. However, non-negligible radiation dose and high costs prevent a systematic usage of this technique for screening purposes. As an alternative, the 3D-Shaper software (3D-Shaper Medical, Spain) reconstructs the 3D shape and density distribution of the femur from 2D DXA scans. This approach could deliver a more accurate estimation of femoral strength than aBMD by using FE analysis on the reconstructed 3D DXA.Methods: Here we present the first independent evaluation of the software, using a dataset of 77 ex vivo femora. We extend a prior evaluation by including the density distribution differences, the spatial correlation of density values and an FE analysis. Yet, cortical thickness is left out of this evaluation, since the cortex is not resolved in our FE models.Results: We found an average surface distance of 1.16 mm between 3D DXA and QCT images, which shows a good reconstruction of the bone geometry. Although BMD values obtained from 3D DXA and QCT correlated well (r2 = 0.92), the 3D DXA BMD were systematically lower. The average BMD difference amounted to 64 mg/cm3, more than one-third of the 3D DXA BMD. Furthermore, the low correlation (r2 = 0.48) between density values of both images indicates a limited reconstruction of the 3D density distribution. FE results were in good agreement between QCT and 3D DXA images, with a high coefficient of determination (r2 = 0.88). However, this correlation was not statistically different from a direct prediction by aBMD. Moreover, we found differences in the fracture patterns between the two image types. QCT-based FE analysis resulted mostly in femoral neck fractures and 3D DXA-based FE in subcapital or pertrochanteric fractures.Discussion: In conclusion, 3D-Shaper generates an altered BMD distribution compared to QCT but, after careful density calibration, shows an interesting potential for deriving a standardized femoral strength from a DXA scan.
30 July 2019 in IEEE Transactions on Biomedical Engineering
Objective: Cardiac pacemakers are powered by batteries, which become exhausted after a few years. This is a problem in particular for leadless pacemakers since they are difficult to explant. Thus, autonomous devices powered by energy harvesters are desired. Methods: We developed an energy harvester for endocardial implantation. The device contains a microgenerator to convert a flexible turbine runner's rotation into electrical energy. The turbine runner is driven by the intracardiac blood flow, a magnetic coupling allows hermetical sealing. The energy harvester has a volume of 0.34 cm $^3$ and a weight of 1.3 g. Computational simulations were performed to assess the hemodynamic impact of the implant. The device was studied on a mock circulation and an in-vivo trial was performed in a domestic pig. Results: In this article we show that an energy harvester with a 2-bladed 14 mm diameter turbine runner delivers 10.2 $\pm$ 4.8 μW under realistic conditions (heart rate 80/min, stroke volume 75 ml) on the bench. An increased output power (> 80 μW) and power density (237.1 μW/cm $^3$ ) can be achieved by higher stroke volumes, increased heart rates or larger turbine runners. The device was successfully implanted in vivo. Conclusion: The device is the first flow-based energy harvester suitable for catheter-based implantation and provides enough energy to power a leadless pacemaker. Significance: The high power density, the small volume, and the flexible turbine runner blades facilitate the integration of the energy harvester in a pacemaker. This would allow overcoming the need for batteries in leadless pacemakers.
23 July 2024 in JBMR Plus
The estimation of BMD with CT scans requires a calibration method, usually based on a phantom. In asynchronous calibration, the phantom is scanned separately from the patient. A standardized acquisition protocol must be used to avoid variations between patient and phantom. However, variations can still be induced, for example, by temporal fluctuations or patient characteristics. Based on the further use of 739 forensic and 111 clinical CT scans, this study uses the proximal femur BMD value (“total hip”) to assess asynchronous calibration accuracy, using in-scan calibration as ground truth. It identifies the parameters affecting the calibration accuracy and quantifies their impact. For time interval and table height, the impact was measured by calibrating the CT scan twice (once using the phantom scan with closest acquisition parameters and once using a phantom scan with standard values) and comparing the calibration accuracy. For other parameters such as body weight, the impact was measured by computing a linear regression between parameter values and calibration accuracy. Finally, this study proposes correction methods to reduce the effect of these parameters and improve the calibration accuracy. The BMD error of the asynchronous calibration, using the phantom scan with the closest acquisition parameters, was −1.2 ± 1.7% for the forensic and − 1.6 ± 3.5% for the clinical dataset. Among the parameters studied, time interval and body weight were identified as the main sources of error for asynchronous calibration, followed by table height and reconstruction kernel. Based on these results, a correction method was proposed to improve the calibration accuracy.
25 April 2026 in Journal of Bone and Mineral Research
The growing interest in 3D-DXA reconstructions for possible uses in fracture risk prediction or patient follow-up, e.g., in conjunction with finite element analyses, asks for precision data to increase the interpretability of results making use of the 3D-DXA technique. Using two datasets and a total of 2427 DXA scans of the proximal femur we evaluated the short- and long-term precision of standard DXA measurements. All the available scans were reconstructed using 3D-Shaper software and processed through a nonlinear finite element pipeline for femoral strength estimation. Short- and long-term precision were computed for thirty 3D-DXA-based parameters as well as femoral strength in fall and stance configurations. Precision errors were related to change rates of the respective parameters by calculating the trend assessment interval (TAI). Simultaneously, spatially resolved precision errors were computed for cortical parameters and error progression from DXA to 3D-DXA and FEA was considered. Precision errors were amplified through the different processing steps. Long-term precision errors were 1.6%, 2.0% and 7.5% for total hip aBMD, total hip integral vBMD and strength in fall, respectively. Errors between processing steps were only weakly correlated. Higher change rates for vBMD and strength compensated the larger precision errors, resulting in similar TAIs for total hip aBMD (5.5 years), total hip integral vBMD (4.6) and strength (5.8), respectively. Relative local precision errors of cortical parameters were largest in the superior and anterior neck region and above the lesser trochanter. 3D-DXA and thereon based FEA may offer interesting insights into the densitometric and mechanical quality of the proximal femur. The here reported results should offer a help for the interpretation of sequential measurements where these are required.
30 March 2026 in Biomechanics and Modeling in Mechanobiology
Fragility hip fractures in older adults are a major burden for the individual and the society, as they result in increased morbidity, mortality and substantial health care expenditure. Most fragility hip fractures are caused by falls, resulting in an impact on the postero-lateral aspect of the hip, inducing a force that exceeds the femoral bone strength. The risk of fracture depends on the rate of falling, the fall-induced impact force, and the femoral bone strength. This article presents the framework of a novel fragility hip fracture risk calculator based on a combined mechanistic and stochastic modelling approach. The model integrates the stochastic aspects of a fall and its dynamics together with a 1D mechanical model predicting the impact force in the hip to calculate a one-year absolute fracture risk. The required input parameters are based on QCT images, but can be substituted with more accessible anthropometric and densitometric data. To demonstrate how the parameters are extracted from clinical data and how the model is calibrated, data from the AFFIRM-CT cohort were used. A sensitivity analysis was conducted, confirming that the fall rate, the trochanteric soft tissue thickness and the bone strength are the dominating parameters influencing the risk of fragility hip fractures. Furthermore, output variables such as the predicted impact velocity and impact force aligned well with experimental data. Thus, the model is able to reflect observations from empirical data, indicating that it can capture the intrinsic aspects that define the risk of fragility hip fractures.