Michael Doube

Michael Doube

Auto-generated profile, based on publicly available information

Michael Doube

Department of Infectious Diseases and Public Health City University of Hong Kong Kowloon Hong Kong

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2010 in Bone
Verified
Journal Article
Closed access
MDMichael Doube
Michael Doube
MKMichał M. Kłosowski
Michał M. Kłosowski
IAIgnacio Arganda-Carreras
Ignacio Arganda-Carreras
FCFabrice Cordelières
Fabrice Cordelières
RDRobert P. Dougherty
Robert P. Dougherty
SSSandra J. Shefelbine
Sandra J. Shefelbine

25 March 2014 in PLOS Biology
Verified
Journal Article
Open access
PDF file
SWSimon M. Walker
Simon M. Walker
DSDaniel A. Schwyn
Daniel A. Schwyn
RMRajmund Mokso
Rajmund Mokso
MWMartina Wicklein
Martina Wicklein
TMTonya Müller
Tonya Müller
GTGraham K. Taylor
Graham K. Taylor
Dipteran flies are amongst the smallest and most agile of flying animals. Their wings are driven indirectly by large power muscles, which cause cyclical deformations of the thorax that are amplified through the intricate wing hinge. Asymmetric flight manoeuvres are controlled by 13 pairs of steering muscles acting directly on the wing articulations. Collectively the steering muscles account for <3% of total flight muscle mass, raising the question of how they can modulate the vastly greater output of the power muscles during manoeuvres. Here we present the results of a synchrotron-based study performing micrometre-resolution, time-resolved microtomography on the 145 Hz wingbeat of blowflies. These data represent the first four-dimensional visualizations of an organism's internal movements on sub-millisecond and micrometre scales. This technique allows us to visualize and measure the three-dimensional movements of five of the largest steering muscles, and to place these in the context of the deforming thoracic mechanism that the muscles actuate. Our visualizations show that the steering muscles operate through a diverse range of nonlinear mechanisms, revealing several unexpected features that could not have been identified using any other technique. The tendons of some steering muscles buckle on every wingbeat to accommodate high amplitude movements of the wing hinge. Other steering muscles absorb kinetic energy from an oscillating control linkage, which rotates at low wingbeat amplitude but translates at high wingbeat amplitude. Kinetic energy is distributed differently in these two modes of oscillation, which may play a role in asymmetric power management during flight control. Structural flexibility is known to be important to the aerodynamic efficiency of insect wings, and to the function of their indirect power muscles. We show that it is integral also to the operation of the steering muscles, and so to the functional flexibility of the insect flight motor. A blowfly's wingbeat is 50 times shorter than a blink of a human eye, and is controlled by numerous tiny steering muscles—some of which are as thin as a human hair. To visualize the movements of these muscles and the deformations of the surrounding exoskeleton, we developed a technique to allow us to look inside the insects during tethered flight. We used a particle accelerator to record high-speed X-ray images of the flying blowflies, which we used to reconstruct three-dimensional tomograms of their flight motor at ten different stages of the wingbeat. We measured the asymmetric movements of the steering muscles associated with turning flight, together with the accompanying movements of the wing hinge—arguably the most complex joint in nature. The steering muscles represent <3% of total flight muscle mass, so a key question has been how they can modulate the output of the much larger power muscles. We show that by shifting the flight motor between different modes of oscillation, the fly is able to divert mechanical energy into a steering muscle that is specialized to absorb mechanical energy. In general, we find that deformations of the muscles and thorax are key to understanding this remarkable mechanism.

22 February 2021 in Wellcome Open Research
Verified
Journal Article
Open access
PDF file
RDRichard Domander
Richard Domander
AFAlessandro A Felder
Alessandro A Felder
MDMichael Doube
Michael Doube
Research software is often developed with expedience as a core development objective because experimental results, but not the software, are specified and resourced as a project output. While such code can help find answers to specific research questions, it may lack longevity and flexibility to make it reusable. We reimplemented BoneJ, our software for skeletal biology image analysis, to address design limitations that put it at risk of becoming unusable. We improved the quality of BoneJ code by following contemporary best programming practices. These include separation of concerns, dependency management, thorough testing, continuous integration and deployment, source code management, code reviews, issue and task ticketing, and user and developer documentation. The resulting BoneJ2 represents a generational shift in development technology and integrates with the ImageJ2 plugin ecosystem.

9 March 2011 in Proceedings Of The Royal Society B-Biological Sciences
Verified
Journal Article
Closed access
MDMichael Doube
Michael Doube
MKMichał M. Kłosowski
Michał M. Kłosowski
AWAlexis M. Wiktorowicz-Conroy
Alexis M. Wiktorowicz-Conroy
JHJohn R. Hutchinson
John R. Hutchinson
SSSandra J. Shefelbine
Sandra J. Shefelbine
Many bones are supported internally by a latticework of trabeculae. Scaling of whole bone length and diameter has been extensively investigated, but scaling of the trabecular network is not well characterized. We analysed trabecular geometry in the femora of 90 terrestrial mammalian and avian species with body masses ranging from 3 g to 3400 kg. We found that bone volume fraction does not scale substantially with animal size, while trabeculae in larger animals' femora are thicker, further apart and fewer per unit volume than in smaller animals. Finite element modelling indicates that trabecular scaling does not alter the bulk stiffness of trabecular bone, but does alter strain within trabeculae under equal applied loads. Allometry of bone's trabecular tissue may contribute to the skeleton's ability to withstand load, without incurring the physiological or mechanical costs of increasing bone mass.

13 October 2015 in Frontiers in Endocrinology
Verified
Journal Article
Open access
PSPhil L. Salmon
Phil L. Salmon
COClaes Ohlsson
Claes Ohlsson
SSSandra J. Shefelbine
Sandra J. Shefelbine
MDMichael Doube
Michael Doube
Structure model index (SMI) is widely used to measure rods and plates in trabecular bone. It exploits the change in surface curvature that occurs as a structure varies from spherical (SMI = 4), to cylindrical (SMI = 3) to planar (SMI = 0). The most important assumption underlying SMI is that the entire bone surface is convex and that the curvature differential is positive at all points on the surface. The intricate connections within the trabecular continuum suggest that a high proportion of the surface could be concave, violating the assumption of convexity and producing regions of negative differential. We implemented SMI in the BoneJ plugin and included the ability to measure the amounts of surface that increased or decreased in area after surface mesh dilation, and the ability to visualize concave and convex regions. We measured SMI and its positive (SMI+) and negative (SMI-) components, bone volume fraction (BV/TV), the fraction of the surface that is concave (CF), and mean ellipsoid factor (EF) in trabecular bone using 38 X-ray microtomography (XMT) images from a rat ovariectomy model of sex steroid rescue of bone loss, and 169 XMT images from a broad selection of 87 species' femora (mammals, birds, and a crocodile). We simulated bone resorption by eroding an image of elephant trabeculae and recording SMI and BV/TV at each erosion step. Up to 70%, and rarely less than 20%, of the trabecular surface is concave (CF 0.155 – 0.700). SMI is unavoidably influenced by aberrations from SMI-, which is strongly correlated with BV/TV and CF. The plate-to-rod transition in bone loss is an erroneous observation resulting from SMI's close and artefactual relationship with BV/TV. SMI cannot discern between the distinctive trabecular geometries typical of mammalian and avian bone, whereas EF clearly detects birds' more plate-like trabeculae. EF is free from confounding relationships with BV/TV and CF. SMI results reported in the literature should be treated with suspicion. We propose that EF should be used instead of SMI for measurements of rods and plates in trabecular bone.

1 April 2014 in Bone
Verified
Journal Article
Closed access
ACA. Carriero
A. Carriero
MDM. Doube
M. Doube
MVM. Vogt
M. Vogt
BBB. Busse
B. Busse
JZJ. Zustin
J. Zustin
SSS.J. Shefelbine
S.J. Shefelbine