18 February 2023 in Izvestiya Vuzov. Tsvetnaya Metallurgiya (Proceedings of Higher Schools. Nonferrous Metallurgy)
Hydro-gas regularities of liquid combined blowing by gas were studied using cold modeling method at Archimedes criterion for lateral Arl = 12÷120 and bottom blowing Arb = 5÷60 simulating Pobeda bubbling unit. The blowing was performed simultaneously by bottom lance vertically fixed in centre of reactor and by the lateral lance which was attached at an angle 5° to the horizontal axis. The quantitative estimation of instantaneous and average circulation velocities (Vav) of liquid flow elements in different bath areas, depending on the location of blowing zone and Archimedes criterion, was performed. The liquid motion trajectory was determined. A vortex zone was revealed near the liquid surface and the reactor shell, where instantaneous velocity of the liquid flow elements changes from 69.9 to 181.1 mm/s and Vav = 123.8 mm/s. The circulation flows fade in the bulk of liquid and Vav decreases from 123.8 to 47.0 and 54.1 mm/s. It was shown that, in general, circulation velocity depends on the blowing intensity and appears to be higher for the zone of overlapping of lateral and bottom streams. The dynamic blowing conditions, which ensure the direct contact of lateral and bottom jets leading to their interflow and increased spatter formation, were identified. The characteristics of 3 types of surface oscillations for interface phases “pure liquid- gas-liquid layer”, as well as the estimation of the lateral and bottom blowing impact on the type of oscillation were provided. It has been noted that the introduction of the bottom blowing (Arb = 5) causes the wave-like motion of liquid (the 2nd type) along with the transverse oscillations of the 1st type, and at higher values of Arb = 25 the angular oscillations of the 3rd type develop. It has been shown that the presence of a lateral jet at the combined blowing decreases angles of bath swinging to 8–12° to horizontal axis. For the estimation of oscillation intensity, Δhl = (hl )max – (hl )min value, which means the difference between maximum (hl )max and minimum (hl )min height of liquid for the full-wave oscillations (τ), was introduced. The height of liquid (hl ) was plotted as a function of τ, Arl , Arb, Δhl was determined on the basis of obtained graph values, which varied upon modeling over the range of 7.7–69.5 mm. The relation between the liquid circulation velocity and the oscillation value (Δhl ) was established for different bath zones and dynamic conditions of the blowing. The impact of all oscillations types on potential erosive lining wear of Pobeda bubbling unit and the completeness of adoption of charging material nearby the bath surface was investigated.
1 November 2015 in Russian Journal of Non-Ferrous Metals
25 December 2024 in iPolytech Journal
The paper aims to find physicochemical patterns in the separation of liquid smelting products with the melt blasted by side and basal tuyeres installed in the area of a “Pobeda” smelting unit intended for charging and melting copper-containing charge. The study adopted the physical simulation method with the use of transparent media (vegetable oil and colored water) and a glass cuvette. The dynamic similarity between the sample and model was ensured by the constancy of the Archimedes number Ar. The initial ratio between the levels of less and more dense fluids was chosen according to the Weber number We. The Archimedes numbers per one side and one basal tuyere amounted to 5;3 and 12;6 (Variants 1 and 2, respectively). The completeness of phase separation was determined visually through filming the liquid-liquid interface emergence and the settlement front advance, as well as quantitatively via the sampling method with subsequent separation of water and oil through centrifugation. According to the condition Ar = idem, the blasting parameters were determined for the cold model with the installation of six basal and three side tuyeres, which were assumed to be located in the sparging zone of the melt. The phase separation patterns are shown to depend on the duration and intensity of the blast. Under Variant 1, blasting is characterized by the formation of a constant phase immiscibility profile at the end of the experiment, which occurs in a limited area of the settlement zone that is far from the sparging zone. At higher Archimedes numbers (Variant 2), the melt pool acquires a homogeneous structure in a shorter time, and no immiscibility boundaries are observed along the entire length of the melt. Thus, a cold modeling technique was developed to study the patterns of phase separation in the presence of a separate sparging zone in the melt pool. This provides a means to obtain objective parameters for the location of tuyeres and blasting conditions, thus ensuring a reduction in the mechanical losses of copper with slag at a given smelting capacity in the “Pobeda” unit.
13 November 2026 in Izvestiya Vuzov. Tsvetnaya Metallurgiya (Proceedings of Higher Schools. Nonferrous Metallurgy)
A laboratory setup was developed, and experiments were conducted to investigate gas bubble growth at a bottom nozzle outlet and determine the gas-liquid interfacial area during gas bubbling. Cold-model experiments showed that the growing bubble successively assumes shapes approximating a spherical cap and a spheroid. A mathematical model was developed to determine the bubble growth time, the instantaneous bubble surface area, and the surface area at detachment. For air injection into pure glycerol at gas flow rates of 30 and 60 dm³/h, the model yields calculated total gas–liquid interfacial areas of 0.0073 and 0.0061 m² over bubble growth periods of 0.17 and 0.12 s, respectively. The discrepancies between the experimental and calculated values range from 1.2 to 12.5 %. A balance of the vertical forces acting on individual regions of the bubble surface was formulated, and an inequality was derived to determine the bubble surface area at the onset of detachment from the force balance. The calculated surface areas at detachment are 5.260·10 –4 and 7.572·10 –4 m². Detachment occurs when the total opposing forces decrease to 17.65 and 25.00 mN, respectively. These surface areas are virtually identical to those predicted by the model based on bubble geometry. The effects of non-isothermal conditions and melt properties on the bubble surface area at detachment were assessed for natural gas injection into molten copper smelting slag at 1623 K. The corresponding balanced force magnitudes increase to 55.2 and 68.7 mN, while the bubble surface areas at detachment decrease to 3.32·10 –4 and 5.37·10 –4 m², respectively. The model can be used to interpret kinetic data for heterogeneous metallurgical reactions obtained in laboratory pyrometallurgical experiments involving bottom injection of a gaseous reactant.