Fugitive emissions are unintentionally produced by pipeline leakage and evaporation in industrial processes and contribute 5% of Global Greenhouse Gas emissions (GHG). Frictional wear and thermal fatigue in vehicle exhaust pipe couplings and joints can cause leaks that are not visible and difficult to quantify. It is therefore essential to trace and document these sources. In this work, an experimental survey was conducted on buses in accordance with Regulation (EC) N° 715/2007 of the European Parliament. Statistical methods by means of a priori analysis aided by GPower 3.1 software was used to define the required sample. Three random sample groups were stratified and fugitive gases were encased and piped into a bronze tube 5 mm in diameter and 500 mm in length. A Horiba PG-300 analyzer was used to analyze the samples using chemiluminescence and infrared methods. The results proved the existence of fugitive emissions in all samples analyzed with variations of (3.000–27.500 ppm) among the samples for , (6.0–138.5 ppm) and (2.0–5.0 ppm) for and , respectively. Statistical analysis showed that engine mileage had no significant influence on emissions, while and emissions increased with mileage. Analysis using Response Surface Methodology (RSM) indicated a trend of increasing concentrations of and for both explanatory variables, mileage and usage time.
Heart failure (HF) is a condition responsible for thousands of deaths each year. It is characterized by the heart's inability to effectively supply blood to the systemic circulation. In such cases, the implantation of a pump known as a left ventricular assist device (LVAD) helps a failing heart restore proper blood flow. However, LVAD implantation may lead to complications such as an increased risk of stroke, thrombus formation, and reverse flow through the aortic valve. This study aims to numerically investigate a section of the aorta coupled to a LVAD pump, using computational fluid dynamics. The objective is to identify how increased LVAD pump speed and blood viscosity impact hemodynamic variables, which may contribute to the adverse effects of mechanical support. Real data from a patient with an implanted LVAD support were analysed using six viscosity models and five different LVAD pump flow rates. Several simulations were conducted to compare the hemodynamic variables' results across different viscosity models. Subsequently, the results for the various LVAD pump flow rates were analyzed. These analyses allowed the identification of critical points within the geometry, associated with the adverse effects of each hemodynamic variable.