Successful rhythm control by standard endocardial methods may become quite challenging in some atrial tachycardia cases, very few of which may need extraordinarily different approaches after the initial failure of extensive endocardial ablation, such as epicardial ablation after subxiphoid puncture, or venous alcohol injection inside the vein of Marshall. With a good understanding of the structures nearby the LA, endocardially failed epicardial ATs can still be successfully ablated without directly entering the pericardial space.
Successful catheter ablation of frequent PVCs in a patient with PVC‐induced cardiomyopathy resulted in a marked improvement in left ventricular ejection fraction (LVEF), accompanied by complete resolution of migraine with aura attacks. This case illustrates both cardiac and neurological benefits of PVC burden reduction through ablation.